Catalog excerpts
LOTUS TM LED Linelight ons opti oling e w Co ava i l a b l Ne now Key Features • Now 50% Brighter (190kLux) • Robust, compact mechanical design with integrated intensity control • Integrated optics for increased intensity and excellent uniformity • 5 year lifetime with maintenance - free operation • Powered directly from 24VDC Compact, Robust, Uniform LED Line Light LOTUS is a compact, robust LED line Light with integrated intensity control designed specifically for machine vision applications. It utilizes the latest in LED technology and optics to produce a bright, uniform light and is modular - available in any length to 5 meters in 100mm increments. In addition, the LOTUS range offers a 5 year lifetime with maintenance free-operation. • Available in a range of wavelengths • Available in any length up to 5 meters (100mm increments) • Water-Cooled option available offering 3 X intensity in the same compact form factor • Fan-Cooled option now available offering 2.5 X intensity in a compact design Following customer feedback, ProPhotonix has developed a new Brighter LOTUS delivering a 50% increase in intensity. In addition, two new cooling options have been developed for applications requiring Key Applications higher intensity, a Fan-cooled LOTUS and Water-cooled LOTUS. As • Linescan a result of these product line extensions, ProPhotonix now offers • Web Inspection LOTUS with more than 4 times the intensity of the previous product. LOTUS is available in a wide range of wavelengths and with a range of optical configurations to suit your specific application needs. www.prophotonix.com
Open the catalog to page 1White LOTUS LED Line Light (LTS) Optical Characteristics LOTUS is available in a range of optical configurations: LI, D1, F1 and B1. See pg 6 for more information Beam Width versus Working Distance For information on longer working distances visit our website Profile Across The Emitting Aperture - B1 Distance from Centre / mm Intensity versus Working Distance Spectral Distribution - White Uniformity - White Distance from Centre / mm Note: Profiles for LI, D1, and F1, were measured at a working distance of 100 mm. Profile for B1 was measured at a working distance of Spectral Characteristics...
Open the catalog to page 2Red LOTUS LED Line Light (LTS) Beam Width versus Working Distance For information on longer working distances visit our website Profile Across The Emitting Aperture Intensity versus Working Distance Distance from Centre / mm Distance from Centre / mm Note: Measured values for L1,D1,andF1 are valid at a working distance of 100 mm. Measured B1 value is valid at a working Spectral Characteristics (1) nominal wavelength and tolerance due to thermal shifting.
Open the catalog to page 3White Fan-Cooled LOTUS LED Line Light (LTF) For profile across the emitting aperture, Spectral distribution and uniformity see pg2. Optical Characteristics 80 Intensity versus Working Distance 80 Beam Width versus Working Distance 70 70 60 450 Width / mmmm Width / 500 60 70 50 Intensity / kLux Intensity / kLux 60 Width / mm Beam Width / mm 80 L1 40 D1 F1 30 B1 20 10 50 100 150 200 250 Working Distance / mm 300 350 L1 D1 D1 D2 40 300 30 D2 F1 250 30 F1 B1 20 200 B1 20 150 10 10 100 0 50 0 0 50 50 50 100 150 200 250 100 Working Distance / mm 250 150 200 100 Working Distance / mm 250 150 200...
Open the catalog to page 4Red Fan- Cooled LOTUS LED Line Light (LTF) For profile across the emitting aperture, Spectral distribution and uniformity see pg 3. 80 Intensity versus Working Distance Beam Width versus Working Distance 80 70 200 70 80 180 60 60 L1 40 D1 F1 30 B1 20 10 Intensity / kLux Intensity / kLux 50 L1 140 50 L1 D1 Width / mmmm Width / 160 50 60 Width / mm Beam Width / mm 70 120 40 40 30 80 20 D1 60 20 B1 40 20 50 100 150 200 250 Working Distance / mm 300 F1 10 10 0 0 0 0 L1 100 30 0 0 0 50 350 100 300 350 50 50 0 100 100 150 200 250 Working Distance / mm 250 150 200 150 200 250 Working Distance / mm...
Open the catalog to page 5DIMENSIONAL DIAGRAM - Fan-Cooled LOTUS 12.5 12.5 5 15 5 9 9 5 15 5 40 9 5 15 5 60 5 5 2 2 ElectronicControl Electronic Control SMA Connector SMA Connector Cable Gland Cable Gland “T”Slots (Compatible with with 5 ITEMTM aluminium profile system) system) "T" Slots (Compatible Size Size 5 ITEM aluminium profile 5 80 80 2 40 9"T" Slots5(Compatible with Size 5 ITEM aluminium profile system) 5 15 Cable Gland 60 Part Numbers TM 12.5 Cooling Fans 40X40X10mm 40 22.5 22.5 6.5 Electronic Control SMA Connector Total Length= WL+34mm Total Length = WL+34mm WL (WindowLength) WL (Window Length) Optical...
Open the catalog to page 6All Photonic Products catalogs and technical brochures
-
COBRA Slim Focusing lens
1 Pages
-
Current Mode Power Supply
2 Pages
-
SpecBright Line Lights
4 Pages
-
SpecBright Ring Lights
4 Pages
-
SpecBright Spot Lights
4 Pages
-
3D Laser Pro Variable Focus
4 Pages
-
Green 3D PRO Laser Mini
4 Pages
-
Custom LED Solutions
4 Pages
-
Product Overview
6 Pages
-
Custom Laser Solutions
4 Pages
-
UV COBRA Slim
6 Pages
-
LOTUS Line Light
6 Pages
-
COBRA
4 Pages
-
3D Pro Variable Focus Laser
4 Pages
-
Green TEC laser module
3 Pages
-
Photon Laser Diode Modules
4 Pages
-
645nm Laser Alignment System
4 Pages
-
3D Pro Laser Mini
4 Pages
-
3D Pro Laser
4 Pages
-
InViso Micro
4 Pages
-
SpecBright? LED Spot Lights
4 Pages
-
SpecBright? LED Ring Lights
4 Pages
-
SpecBright? LED Area Lights
4 Pages
-
SpecBright? LED Line Lights
4 Pages
-
COBRA Flex
8 Pages
-
COBRA? Max
4 Pages
-
COBRA Slim
8 Pages
-
Compact Laser Diode Modules
2 Pages
-
ProPhotonix Product
12 Pages
-
Photon laser diode module
3 Pages
-
Industrial Laser Module
4 Pages
-
Industrial Variable Focus
4 Pages
Archived catalogs
-
Opnext Laser Diode Catalogue
12 Pages
-
SANYO Laser Diode Catalogue 2008
20 Pages