Quick Start Measurement UV254 Go

Quick Start Measurement UV254 Go

Product catalog summary
Quick Start Guide for UV254 Measurement with Go Device
Device Setup and Initial Steps:
  • Turn on the Go device.
  • Insert the reference cell, typically containing distilled water, into the device.
  • Click to proceed.
Sample Measurement:
  • Place the sample into the Go device using the same cell as the reference for consistency.
  • Click to measure.
Measurement Routines:
  • UVT/UVA: Measures UV transmission and absorbance at 254nm.
  • SUVA: Provides measurements related to EPA415.3, requiring DOC input from another device.
  • Locations: User-calibrated measurements of parameters that correlate to UV254 absorption, such as TOC, DOC, COD, and BOD.

*Refer to the calibration quick start for calibration procedures.

Measurement Process:
  • Ensure the optical path is aligned from left to right at the front of the Go device.
  • Align the clear sides of the cuvettes/cells with the optical path.
  • Click to measure.
Additional Information:
  • The device is designed for experts in UV254 measurements.
See more

Catalog excerpts

Quick Start Measurement UV254 Go-1

Quick Start Measurement UV254 Go Place reference cell into Go This will usually be distilled water Click Measure Click Select the measurement routine UVT/UVA - Measurement of UV transmission and absorbance at 254nm SUVA – Provides a measurement in relation to EPA415.3. DOC input is required from another device as part of the method. Locations – These are user calibrated measurements of parameters / surrogates that corelate to UV254 absorption. Such parameters as TOC, DOC, COD and BOD amongst others can be calibrated to UV254 Place sample into Go and measure Its best practice to use the same cell as was used during the reference Click UVT/UVA – Absorption and transmission measurements at UV254 *For calibration please see the calibration quick start Optical path is left to right of the front of the Go. Make sure the clear sides of cuvettes/cells are aligned with this. User Calibrated ParametersSurrogate parameters that corelate to the UV254 absorpt