SignalSure 75 Mid power solution SignalSure 75 is a compact, surface-mount, mid power LED signaling solution that delivers an elevated standard of light output, flux density, and color uniformity. SignalSure’s robust design structure, coupled with high performance specifications, ensures high quality and reliability. SignalSure 75 is AEC-Q101D qualified. SignalSure 75 is available in the following color wavelengths: –– Amber (591nm) –– Red Orange (615nm) –– Super Red (630nm) –– Super Red (635nm) Primary ApplicationS Higher drive current capability for increased flux performance Mirror/Side Repeater Low thermal resistance for better hot lumen performance Standard packaging for low cost and ease of manufacturability Available in 591nm, 615nm, 630nm and 635nm colors for increased design options –– CHMSL Turn DS126 SignalSure 75 Product Datasheet ©2016 Lumileds Holding B.V.
Open the catalog to page 1Table of Contents General Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Environmental Compliance . . . . . . . . . . . . . ....
Open the catalog to page 2General Product Information Product Test Conditions SignalSure 75 LEDs are tested and binned using a 20ms monopulse (MP) at 75mA drive current, junction temperature, Tj, of 25ºC. Part Number Nomenclature Part numbers for SignalSure 75 follow the convention below: A 1 D P – B C C C L D 7 E F G H 0 0 Where: B – designates color (A=Amber, O=Red Orange and S=Super Red) C C C – designates minimum dominant wavelength (588=588nm, 612=612nm, 627=627nm and 632=632nm) D – designates the binning condition (1=single binning (75mA), 8=dual binning (75mA and 5mA) – designates minimum flux bin (See Product...
Open the catalog to page 3Product Selection Guide Table 1. Product selection for SignalSure 75 at 20ms MP, 75mA, T=25°C. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 4Absolute Ratings Table 4. Absolute ratings for SignalSure 75. Parameter Minimum DC Forward Current Maximum DC Forward Current Maximum Junction Temperature Operating Case Temperature at Test Current [1] Operating Case Temperature at Maximum Current [1] Storage Temperature Soldering Temperature Allowable Reflow Cycles Notes for Table 4: 1. Proper current derating must be observed to maintain junction temperature below the maximum, so that the LED is maintained below the maximum rated operating case temperature. SignalSure LEDs driven at or above the maximum rated operating case temperature may...
Open the catalog to page 5Light Output Characteristics Figure 2. Typical normalized light output vs. junction temperature for SignalSure 75 at 20ms MP, 75mA. Figure 3. Typical normalized light output vs. forward current for SignalSure 75 at Tj=25ºC. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 6Forward Current Characteristics Figure 4a. Typical forward current vs. forward voltage for SignalSure 75 at Tj=25ºC. Figure 4b. Typical forward voltage shift vs. junction temperature for SignalSure 75 at 20ms MP, specified test current. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 7Radiation Pattern Characteristics Figure 5. Typical radiation pattern for SignalSure 75 at 20ms MP, 75mA. Operating Limits Characteristics 100 90 Figure 6. Maximum forward current vs. case temperature for SignalSure 75. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 8Permissible Pulse Handling Characteristics Figure 7. Permissible pulse handling capability for SignalSure 75. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 9Designing with SignalSure Flux bins supportable for car programs depend on product color and program start- and end-of-production date. Flux roadmaps by year and product color are maintained and available from the sales representative. Please contact your local sales representative to request the flux bin range with best supportability for program timing. Decoding Product Bin Labeling In the manufacturing of semiconductor products, there are variations in performance around the average values given in the technical datasheets. For this reason, Lumileds bins the LED components for luminous flux,...
Open the catalog to page 10Notes for Table 5a: 1. Lumileds maintains a tolerance of ±10% on luminous flux measurements. Notes for Table 5b: 1. Lumileds maintains a tolerance of ±10% on luminous flux measurements. 2. Applies to dual binning option only. Table 5c. Luminous flux bin pairing for SignalSure 75 at 20ms MP, 75mA and 5mA, Tj=25°C. Notes for Table 5c: 1. Applies to dual binning option only. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 11Notes for Table 6: 1. Lumileds maintains a tolerance of ±1nm on dominant wavelength measurements. Notes for Table 7a: 1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. 2. Applies to dual binning option only. Notes for Table 7b: 1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. 2. Applies to dual binning option only. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 12Table 7c. Forward voltage bin pairing for SignalSure 75 at 20ms MP, 75mA and 5mA, Tj=25°C . Notes for Table 7c: 1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. 2. Applies to dual binning option only. Cathode Mark Notes for Figure 8: 1. Drawings are not to scale. 2. All dimensions are in millimeters. 02.40 +ve +ve Note: SC = Special Characteristics General Tolerances: ±0.10 Figure 8. Mechanical dimensions for SignalSure 75. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 1320 Pages
25 Pages
41 Pages
15 Pages
19 Pages
13 Pages
11 Pages
16 Pages
4 Pages
25 Pages
19 Pages
2 Pages
2 Pages
2 Pages
2 Pages
16 Pages
19 Pages
21 Pages
16 Pages
31 Pages
13 Pages
14 Pages
20 Pages
25 Pages
9 Pages
18 Pages
22 Pages
22 Pages
10 Pages
17 Pages
15 Pages
17 Pages
2 Pages
4 Pages
17 Pages
15 Pages
23 Pages
22 Pages
18 Pages
33 Pages
21 Pages
17 Pages
17 Pages
17 Pages
23 Pages
28 Pages
20 Pages
18 Pages
18 Pages
20 Pages
34 Pages
21 Pages
27 Pages
25 Pages
15 Pages
15 Pages
19 Pages
24 Pages
4 Pages
16 Pages
21 Pages
20 Pages
23 Pages
28 Pages
17 Pages
17 Pages
19 Pages
33 Pages
12 Pages
12 Pages
15 Pages
14 Pages
16 Pages
28 Pages
2 Pages
2 Pages
2 Pages
2 Pages
24 Pages
18 Pages
30 Pages
35 Pages
19 Pages
34 Pages
17 Pages
29 Pages
34 Pages
2 Pages
5 Pages
9 Pages
25 Pages
31 Pages
41 Pages