Catalog excerpts
SignalSure 75 Mid power solution SignalSure 75 is a compact, surface-mount, mid power LED signaling solution that delivers an elevated standard of light output, flux density, and color uniformity. SignalSure’s robust design structure, coupled with high performance specifications, ensures high quality and reliability. SignalSure 75 is AEC-Q101D qualified. SignalSure 75 is available in the following color wavelengths: –– Amber (591nm) –– Red Orange (615nm) –– Super Red (630nm) –– Super Red (635nm) Primary ApplicationS Higher drive current capability for increased flux performance Mirror/Side Repeater Low thermal resistance for better hot lumen performance Standard packaging for low cost and ease of manufacturability Available in 591nm, 615nm, 630nm and 635nm colors for increased design options –– CHMSL Turn DS126 SignalSure 75 Product Datasheet ©2016 Lumileds Holding B.V.
Open the catalog to page 1Table of Contents General Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Environmental Compliance . . . . . . . . . . . . ....
Open the catalog to page 2General Product Information Product Test Conditions SignalSure 75 LEDs are tested and binned using a 20ms monopulse (MP) at 75mA drive current, junction temperature, Tj, of 25ºC. Part Number Nomenclature Part numbers for SignalSure 75 follow the convention below: A 1 D P – B C C C L D 7 E F G H 0 0 Where: B – designates color (A=Amber, O=Red Orange and S=Super Red) C C C – designates minimum dominant wavelength (588=588nm, 612=612nm, 627=627nm and 632=632nm) D – designates the binning condition (1=single binning (75mA), 8=dual binning (75mA and 5mA) – designates minimum flux bin (See...
Open the catalog to page 3Product Selection Guide Table 1. Product selection for SignalSure 75 at 20ms MP, 75mA, T=25°C. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 4Absolute Ratings Table 4. Absolute ratings for SignalSure 75. Parameter Minimum DC Forward Current Maximum DC Forward Current Maximum Junction Temperature Operating Case Temperature at Test Current [1] Operating Case Temperature at Maximum Current [1] Storage Temperature Soldering Temperature Allowable Reflow Cycles Notes for Table 4: 1. Proper current derating must be observed to maintain junction temperature below the maximum, so that the LED is maintained below the maximum rated operating case temperature. SignalSure LEDs driven at or above the maximum rated operating case temperature...
Open the catalog to page 5Light Output Characteristics Figure 2. Typical normalized light output vs. junction temperature for SignalSure 75 at 20ms MP, 75mA. Figure 3. Typical normalized light output vs. forward current for SignalSure 75 at Tj=25ºC. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 6Forward Current Characteristics Figure 4a. Typical forward current vs. forward voltage for SignalSure 75 at Tj=25ºC. Figure 4b. Typical forward voltage shift vs. junction temperature for SignalSure 75 at 20ms MP, specified test current. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 7Radiation Pattern Characteristics Figure 5. Typical radiation pattern for SignalSure 75 at 20ms MP, 75mA. Operating Limits Characteristics 100 90 Figure 6. Maximum forward current vs. case temperature for SignalSure 75. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 8Permissible Pulse Handling Characteristics Figure 7. Permissible pulse handling capability for SignalSure 75. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 9Designing with SignalSure Flux bins supportable for car programs depend on product color and program start- and end-of-production date. Flux roadmaps by year and product color are maintained and available from the sales representative. Please contact your local sales representative to request the flux bin range with best supportability for program timing. Decoding Product Bin Labeling In the manufacturing of semiconductor products, there are variations in performance around the average values given in the technical datasheets. For this reason, Lumileds bins the LED components for luminous...
Open the catalog to page 10Notes for Table 5a: 1. Lumileds maintains a tolerance of ±10% on luminous flux measurements. Notes for Table 5b: 1. Lumileds maintains a tolerance of ±10% on luminous flux measurements. 2. Applies to dual binning option only. Table 5c. Luminous flux bin pairing for SignalSure 75 at 20ms MP, 75mA and 5mA, Tj=25°C. Notes for Table 5c: 1. Applies to dual binning option only. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 11Notes for Table 6: 1. Lumileds maintains a tolerance of ±1nm on dominant wavelength measurements. Notes for Table 7a: 1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. 2. Applies to dual binning option only. Notes for Table 7b: 1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. 2. Applies to dual binning option only. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 12Table 7c. Forward voltage bin pairing for SignalSure 75 at 20ms MP, 75mA and 5mA, Tj=25°C . Notes for Table 7c: 1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. 2. Applies to dual binning option only. Cathode Mark Notes for Figure 8: 1. Drawings are not to scale. 2. All dimensions are in millimeters. 02.40 +ve +ve Note: SC = Special Characteristics General Tolerances: ±0.10 Figure 8. Mechanical dimensions for SignalSure 75. DS126 SignalSure 75 Product Datasheet 20160509 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 13All Philips Lumileds Lighting Company catalogs and technical brochures
-
LUXEON 5052 RGBW
20 Pages
-
LUXEON Z Color Line
25 Pages
-
LUXEON Rubix
41 Pages
-
LUXEON FlipChip Royal Blue
15 Pages
-
LUXEON 3030 HE Plus
19 Pages
-
LUXEON XR-5050 Round
13 Pages
-
LUXEON XR-5050 HE
11 Pages
-
LUXEON Mid-Power White LEDs
16 Pages
-
LUXEON Color Portfolio
4 Pages
-
LUXEON Altilon SMD
25 Pages
-
LUXEON Neo
19 Pages
-
Turn indicator
2 Pages
-
Front fog
2 Pages
-
Stop/tail
2 Pages
-
DRL
2 Pages
-
SignalSure 30 Low power solution
16 Pages
-
LUXEON FlipChip Royal Blue
17 Pages
-
LUXEON R_2014-2015
19 Pages
-
LUXEON FlipChip White
21 Pages
-
LUXEON 5050
16 Pages
-
LUXEON Rebel Color Line
31 Pages
-
LUXEON XF-3014 CV
13 Pages
-
LUXEON XR-M
14 Pages
-
LUXEON 3030 HV
20 Pages
-
LUXEON 3535L Line (Legacy)
25 Pages
-
LUXEON XR-TX
9 Pages
-
LUXEON HR30
18 Pages
-
LUXEON CoB Core Range (Gen 3)
22 Pages
-
LUXEON 2835 Line
22 Pages
-
LUXEON XR-3020
10 Pages
-
LUXEON CoB Compact Range (Gen 2)
17 Pages
-
SnapLED Xtreme
15 Pages
-
LUXEON F PC Amber
17 Pages
-
Illumination Color Line Card
2 Pages
-
Illumination Line Card
4 Pages
-
LUXEON FlipChip UV
17 Pages
-
LUXEON Z UV
15 Pages
-
LUXEON M
23 Pages
-
LUXEON MZ
22 Pages
-
LUXEON Q
18 Pages
-
LUXEON Rebel ES
33 Pages
-
LUXEON Rebel
21 Pages
-
LUXEON Rebel PLUS
17 Pages
-
LUXEON TX
17 Pages
-
LUXEON Z
17 Pages
-
LUXEON Z ES
23 Pages
-
LUXEON K
28 Pages
-
LUXEON S
20 Pages
-
LUXEON XF-3535L
18 Pages
-
LUXEON 3014
18 Pages
-
LUXEON 3020
20 Pages
-
LUXEON 3535 2D
34 Pages
-
LUXEON 3535 HV
21 Pages
-
LUXEON 3535L
27 Pages
-
LUXEON 4014
25 Pages
-
SignalSure 250
15 Pages
-
SnapLED 150
15 Pages
-
LUXEON 3030 2D
19 Pages
-
LUXEON Altilon
24 Pages
-
Lamps Application Solutions
4 Pages
-
LUXEON General Illumination
16 Pages
-
LUXEON H 50-2
21 Pages
-
LUXEON S2000, S3000, S5000
20 Pages
-
LUXEON H 100/200
23 Pages
-
LUXEON Z Color
28 Pages
-
Lead-Free SuperFlux LEDs
17 Pages
-
LUXEON C
17 Pages
-
LUXEON R 2014
19 Pages
-
LUXEON Rebel ANSI
33 Pages
-
LUXEON XR-3535L
12 Pages
-
LUXEON FlipChip
12 Pages
-
LUXEON UV
15 Pages
-
SuperFlux LEDs
14 Pages
-
LUXEON T
16 Pages
-
LUXEON Mid-Power 5630
28 Pages
-
PB103LUXEON M
2 Pages
-
LUXEON H - 100/200V
2 Pages
-
LUXEON Rebel ES Blue
2 Pages
-
LUXEON Products
2 Pages
-
LUXEON H Datasheet
19 Pages
-
LUXEON A Datasheet
24 Pages
-
LUXEON C Power LED
18 Pages
-
Technical Datasheet DS64
30 Pages
-
Technical Datasheet DS61
35 Pages
-
Technical Datasheet DS63
34 Pages
Archived catalogs
-
2023 LUXEON C Color Line
34 Pages
-
2016 LUXEON C Color Line
29 Pages
-
LUXEON R_2012
2 Pages
-
SnapLED 70
5 Pages
-
Lead Free SuperFlux LEDs
9 Pages
-
LUXEON® Rebel ES
25 Pages
-
LUXEON® Rebel
31 Pages
-
LUXEON K2 Datasheet
41 Pages