SignalSure 30 Low power solution SignalSure 30 is a compact, surface-mount, low power LED signaling solution that delivers an elevated standard of light output, flux density, and color uniformity. SignalSure’s robust design structure, coupled with high performance specifications, ensures high quality and reliability. SignalSure 30 is AEC-Q101D qualified. SignalSure 30 is available in the following color wavelengths: –– Red Orange (615nm) –– Super Red (630nm) –– Super Red (635nm) Primary Applications Higher drive current capability for increased flux performance Mirror/Side Repeater Low thermal resistance for better hot lumen performance Economic package for high quantity Tail Lamp solutions Available in 615nm, 630nm and 635nm colors for increased design options AEC-Q101D qualified DS147 SignalSure 30 Product Datasheet ©2016 Lumileds Holding B.V. All
Open the catalog to page 1Table of Contents General Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Environmental Compliance . . . . . . . . . . . . . ....
Open the catalog to page 2SignalSure 30 LEDs are tested and binned using a 20ms monopulse (MP) at 30mA drive current, junction temperature, Tfof 25°C. Part numbers for SignalSure 30 follow the convention below: Where: B - designates color (O=Red Orange and S=Super Red) C C C - designates minimum dominant wavelength (612=612nm, 627=627nm and 632=632nm) D - designates minimum flux bin (see Product Bin and Labeling section) E - designates the flux bin range (3=3 subsequent flux bins including the minimum bin) F G - designates forward voltage range in which F is the minimum Vf bin and G is the maximum Vf bin (see Product...
Open the catalog to page 3DS147 SignalSure 30 Product Datasheet 20160508 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 4Minimum DC Forward Current Maximum DC Forward Current Maximum Junction Temperature [1] Operating Case Temperature at Test Current [1] Operating Case Temperature at Maximum Current [1] LED Storage Temperature Soldering Temperature Allowable Reflow Cycles Minimum ESD performance 121 Reverse Voltage (Vr) Notes for 4: 1. Proper current derating must be observed to maintain junction temperature below the maximum, so that the LED is maintained below the maximum rated operating case temperature. SignalSure LEDs driven at or above the maximum rated operating case temperature may have shorter lifetime....
Open the catalog to page 5Light Output Characteristics Figure 2. Typical normalized light output vs. junction temperature for SignalSure 30 at 20ms MP, 30mA. Figure 3. Typical normalized light output vs. forward current for SignalSure 30 at Tj=25ºC. DS147 SignalSure 30 Product Datasheet 20160508 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 6Forward Current Characteristics Figure 4a. Typical forward current vs. forward voltage for SignalSure 30 at Tj=25ºC. Figure 4b. Typical forward voltage shift vs. junction temperature for SignalSure 30 at 20ms MP, specified test current. DS147 SignalSure 30 Product Datasheet 20160508 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 7Radiation Pattern Characteristics Figure 5. Typical radiation pattern for SignalSure 30 at 20ms MP, 30mA. Operating Limits Characteristics Figure 6. Maximum forward current vs. case temperature for SignalSure 30. DS147 SignalSure 30 Product Datasheet 20160508 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 8Permissible Pulse Handling Characteristics Figure 7. Permissible pulse handling capability for SignalSure 30. DS147 SignalSure 30 Product Datasheet 20160508 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 9Designing with SignalSure Flux bins supportable for car programs depend on product color and program start- and end-of-production date. Flux roadmaps by year and product color are maintained and available from the sales representative. Please contact a local sales representative to request the flux bin range with best supportability for program timing. Decoding Product Bin Labeling In the manufacturing of semiconductor products, there are variations in performance around the average values given in the technical datasheets. For this reason, Lumileds bins the LED components for luminous flux or...
Open the catalog to page 10Color Codes Table 6. Color code definitions for SignalSure 30 at 20ms MP, 30mA, Tj=25°C. DOMINANT WAVELENGTH (nm) Notes for Table 6: 1. Lumileds maintains a tolerance of ±1nm on dominant wavelength measurements. Forward Voltage Bins Table 7. Forward voltage bin definitions for SignalSure 30 at 20ms MP, 30mA, Tj=25°C. Forward Voltage (Vf) Notes for Table 7: 1. Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. Mechanical Dimensions Cathode mark Figure 8. Mechanical dimensions for SignalSure 30. Notes for Figure 8: 1. Drawings are not to scale. 2. All dimensions are in millimeters....
Open the catalog to page 11Table 8. Reflow profile characteristics for SignalSure 30. PROFILE FEATURE LEAD FREE ASSEMBLY Preheat Minimum Temperature (Tsmin) Preheat Maximum Temperature (Tsmax) Preheat Time (tsmin to tsmax) Ramp-Up Rate (TL to Tp) Liquidus Temperature (TL) Time Maintained Above Temperature TL (tL) Peak / Classification Temperature (Tp) Time Within 5°C of Actual Temperature (tp) Ramp-Down Rate (Tp to TL) Time 25°C to Peak Temperature Notes for Table 8: 1. All temperatures refer to the application Printed Circuit Board (PCB), measured on the surface adjacent to the package body. Notes for Table 9: 1. Shelf...
Open the catalog to page 12Figure 10. Recommended PCB solder pad layout for SignalSure 30. Notes for Figure 10: 1. The drawing shows the recommended SignalSure 30 layout on Printed Circuit Board (PCB). 2. All dimensions are in millimeters. DS147 SignalSure 30 Product Datasheet 20160508 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 1320 Pages
25 Pages
41 Pages
15 Pages
19 Pages
13 Pages
11 Pages
16 Pages
4 Pages
25 Pages
19 Pages
2 Pages
2 Pages
2 Pages
2 Pages
18 Pages
19 Pages
21 Pages
16 Pages
31 Pages
13 Pages
14 Pages
20 Pages
25 Pages
9 Pages
18 Pages
22 Pages
22 Pages
10 Pages
17 Pages
15 Pages
17 Pages
2 Pages
4 Pages
17 Pages
15 Pages
23 Pages
22 Pages
18 Pages
33 Pages
21 Pages
17 Pages
17 Pages
17 Pages
23 Pages
28 Pages
20 Pages
18 Pages
18 Pages
20 Pages
34 Pages
21 Pages
27 Pages
25 Pages
15 Pages
15 Pages
19 Pages
24 Pages
4 Pages
16 Pages
21 Pages
20 Pages
23 Pages
28 Pages
17 Pages
17 Pages
19 Pages
33 Pages
12 Pages
12 Pages
15 Pages
14 Pages
16 Pages
28 Pages
2 Pages
2 Pages
2 Pages
2 Pages
24 Pages
18 Pages
30 Pages
35 Pages
19 Pages
34 Pages
17 Pages
29 Pages
34 Pages
2 Pages
5 Pages
9 Pages
25 Pages
31 Pages
41 Pages