LUXEON Z ES
1 /23Pages

LUXEON Z ES

LUXEON Z ES
1 /23Pages

Catalog excerpts

LUXEON Z ES-1

GENERAL ILLUMINATION LUXEON Z ES Extreme flux density in a micro footprint package for precise optical control LUXEON Z ES is a high-power 1.6mm x 2.0mm LED that enables never before seen color consistency, luminance, flux density and design flexibility for lighting solutions. It is the first ever 1-step MacAdam ellipse warm white LED. LUXEON Z ES is undomed, a feature that provides unmatched optical flexibility for precise beam angle control. Tested and binned at application conditions, 85°C, the LUXEON Z ES emitters are an ideal choice for indoor and outdoor light sources requiring superior beam angles, higher efficacy and lower costs. PRIMARY APPLICATIONS Micro footprint enables close packaging Indoor Area Lighting Undomed design allows precise optical control 1-, 3- and 5-step MacAdam ellipse: Freedom from Binning enabling color consistency LM-80 test report available DS134 LUXEON Z ES Product Datasheet ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 1
LUXEON Z ES-2

Table of Contents General Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Lumen Maintenance . . . . . . . . . . . . . . . . ....

 Open the catalog to page 2
LUXEON Z ES-3

General Product Information Product Test Conditions LUXEON Z ES are tested and binned with a drive current of 700mA for 3V part or 40mA for 48V part at a junction temperature, Tj, of 85°C. Part Number Nomenclature Part numbers for LUXEON Z ES follow the convention below: L X Z A – B C D E – F Where: A designates nominal ANSI CCT or color (eg. 27=2700K, 30=3000K and PR=Royal Blue) designates minimum CRI performance (70=70CRI, 80=80CRI, 90=90CRI, 02=Royal Blue) designates white color space definition (1=1 SDCM, 3=3 SDCM and 5=5 SDCM, not used for Royal Blue) Therefore, the following part number...

 Open the catalog to page 3
LUXEON Z ES-4

Performance Characteristics Product Selection Guide Table 1a. Product performance of LUXEON Z ES3V at 700mA and 350mA, T^SS-C. 1. Lumileds maintains a tolerance of ±6.5% on both luminous flux and radiometric power and ±2 on CRI measurements. 2. In the part number the -x is the designation for the white color space requirement. On 80CRI and 90CRI versions -1 designates 1 SDCM, -3 designates 3 SDCM, -5 designates 5 SDCM. 70 CRI oarts or lower will not have a SDCM designation and all parts are binned within a 5 step SDCM. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All...

 Open the catalog to page 4
LUXEON Z ES-5

Optical Characteristics Table 2. Optical characteristics for LUXEON Z ES at 700mA. PART NUMBER TYPICAL TOTAL INCLUDED ANGLE [1] TYPICAL VIEWING ANGLE [2] Notes for Table 2: 1. Total angle at which 90% of total luminous flux is captured. 2. Viewing angle is the off axis angle from the LED centerline where the luminous intensity is ½ of the peak value. Electrical and Thermal Characteristics Table 3a. Electrical and thermal characteristics for LUXEON Z ES at 700mA. FORWARD VOLTAGE (V) MINIMUM TYPICAL TEMPERATURE COEFFICIENT OF FORWARD VOLTAGE (mV/°C) TYPICAL THERMAL RESISTANCE JUNCTION TO SOLDER...

 Open the catalog to page 5
LUXEON Z ES-6

Absolute Maximum Ratings Table 4. Absolute maximum ratings for LUXEON Z ES. PARAMETER MAXIMUM PERFORMANCE Peak Pulsed Forward Current [1,3] LED Junction Temperature [1] (DC & Pulse) 8000V Human Body Model (HBM) Class 3B JEDEC JS-001-2012 Operating Case Temperature Storage Temperature Soldering Temperature Allowable Reflow Cycles Reverse Voltage (Vreverse) [4, 5] LUXEON LEDs are not designed to be driven in reverse bias Notes for Table 4: 1. Proper current derating must be observed to maintain junction temperature below the maximum. 2. Residual periodic variations due to power conversion from...

 Open the catalog to page 6
LUXEON Z ES-7

Characteristic Curves Spectral Power Distribution Characteristics Figure 1: Typical normalized power vs. wavelength for LXZx-xxxx at test current, Tj=85°C. Figure 2: Typical normalized power vs. wavelength for LXZ2-PR02 at 700mA, Tj=85°C. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 7
LUXEON Z ES-8

Light Output Characteristics Figure 3a: Typical normalized light output vs. junction temperature for LXZx-xxxx, at test current. Figure 3b: Typical normalized light output vs. forward current for LXZH-xxxx-x, Ti=85°C. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 8
LUXEON Z ES-9

Figure 4a: Typical normalized light output vs. junction temperature for LXZ2-PR02, at test current. Figure 4b: Typical normalized light output vs. forward current for LXZx-xxxx, Tj=85°C. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 9
LUXEON Z ES-10

Figure 4c: Normalized radiometric power vs. forward current for LXZ2-PR02, Tj=85°C. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 10
LUXEON Z ES-11

Forward Current Characteristics Figure 5a: Typical forward current vs. forward voltage for LXZx-xxxx, Tj=85ºC. Figure 5b: Typical forward current vs. forward voltage for LXZH-2780-x, Tj=85ºC. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 11
LUXEON Z ES-12

Figure 5c: Typical forward current vs. forward voltage for LXZ2-PR02, Tj=85°C. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 12
LUXEON Z ES-13

Radiation Pattern Characteristics Angular Displacement [degrees] Figure 6a: Typical radiation pattern for LXZx-xxxx (white only) at test current. Angle [degrees] Figure 6b: Typical radiation pattern for LXZ2-PR02 at test current. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 13
LUXEON Z ES-14

Figure 7a: Typical polar radiation pattern for LXZx-xxxx (white only) at test current. Figure 7b: Typical polar radiation pattern for LXZ2-PR02 at test current. DS134 LUXEON Z ES Product Datasheet 20150616 ©2015 Lumileds Holding B.V. All rights reserved.

 Open the catalog to page 14

All Philips Lumileds Lighting Company catalogs and technical brochures

  1. LUXEON Rubix

    41  Pages

  2. LUXEON Neo

    19  Pages

  3. Front fog

    2  Pages

  4. Stop/tail

    2  Pages

  5. DRL

    2  Pages

  6. LUXEON 5050

    16  Pages

  7. LUXEON XR-M

    14  Pages

  8. LUXEON 3030 HV

    20  Pages

  9. LUXEON XR-TX

    9  Pages

  10. LUXEON HR30

    18  Pages

  11. LUXEON XR-3020

    10  Pages

  12. SnapLED Xtreme

    15  Pages

  13. LUXEON Z UV

    15  Pages

  14. LUXEON M

    23  Pages

  15. LUXEON MZ

    22  Pages

  16. LUXEON Q

    18  Pages

  17. LUXEON Rebel ES

    33  Pages

  18. LUXEON Rebel

    21  Pages

  19. LUXEON TX

    17  Pages

  20. LUXEON Z

    17  Pages

  21. LUXEON K

    28  Pages

  22. LUXEON S

    20  Pages

  23. LUXEON XF-3535L

    18  Pages

  24. LUXEON 3014

    18  Pages

  25. LUXEON 3020

    20  Pages

  26. LUXEON 3535 2D

    34  Pages

  27. LUXEON 3535 HV

    21  Pages

  28. LUXEON 3535L

    27  Pages

  29. LUXEON 4014

    25  Pages

  30. SignalSure 250

    15  Pages

  31. SnapLED 150

    15  Pages

  32. LUXEON 3030 2D

    19  Pages

  33. LUXEON Altilon

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.