LUXEON XR-5050 HE High performance LED modules with extreme efficacy for robust lighting designs LUXEON XR-5050 HE integrated modules are standard products compatible with off-the-shelf drivers, optics, and heat sinks. These versatile building blocks feature 8, 12, 16 or 24 LUXEON 5050 HE LEDs on a MCPCB substrate for thermal efficiency and mechanical robustness. This approach simplifies system integration and accelerates time-to-market. PRIMARY APPLICATIONS Efficacy and Luminous flux of up to 191lm/W typ and 8636lm available Superior board level color control of ≤ 3SDCM Sport Lights MCPCB for efficient heat dissipation and mechanical robustness Outdoor Area Lights UL 8750, ENEC, ENEC+, CE, UKCA compliance Roadway Lights 5-year limited guarantee Designs compatible with standard third-party optics DS413 LUXEON XR-5050 HE Product Datasheet ©2026 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 1Table of Contents General Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Lumen Maintenance . . . . . . . . . . . . . . . . ....
Open the catalog to page 2LUXEON XR-5050 HE 8up, 12up and 16up modules are tested using a 20ms monopulse (MP) at 700mA and a case temperature, T of 85°C LUXEON XR-5050 HE 24up modules are tested using a 20ms monopulse (MP) at 1050mA, case temperature Tc of 85°C. Part numbers for LUXEON XR-5050 HE follow the convention below: A A - designates nominal ANSI CCT (22=2200K, 27=2700K, 30=3000K, 35=3500K, 40=4000K, 50=5000K, C C - designates number of emitters (08=8 emitters, 12=12 emitters, 16=16 emitters, 24=24 emitters) D D - designates internal Lumileds program code 1 0 - designates internal Lumileds program code Therefore,...
Open the catalog to page 3Product Selection Guide Table 1a. Product performance of LUXEON XR-5050 HE 8up, 12up and 16up at 700mA, Tc=85°C NOMINALCCT MINIMUM CRI [1 2 LUMINOUS FLUX [1] (lm) TYPICAL LUMINOUS EFFICACY (Im/W) ENERGY EFFICIENCY CLASS [3] PART NUMBER 2200K 1. Lumileds maintains a tolerance of ±2 on CRI and ±7% on luminous flux measurements. 2. Typical CRI is approximately 2 points higher than the minimum CRI specified, but this is not guaranteed. 3. Energy efficiency class as specified in Commission Delegated Regulation (EU) 2019/2015. The available range of energy efficiency classes is A-G. DS413 LUXEON XR-5050...
Open the catalog to page 4NOMINAL MINIMUM TYPICAL LUMINOUS EFFICACY (Im/W) ENERGY EFFICIENCY CLASS [3] PART NUMBER 1. Lumileds maintains a tolerance of ±2 on CRI and ±7% on luminous flux measurements. 2. Typical CRI is approximately 2 points higher than the minimum CRI specified, but this is not guaranteed. 3. Energy efficiency class as specified in Commission Delegated Regulation (EU) 2019/2015. The available range of energy efficiency classes is A-G. 1. Lumileds maintains a tolerance of ±0.1V on forward voltage measurements. DS413 LUXEON XR-5050 HE Product Datasheet 20260106 ©2026 Lumileds Holding B.V. All rights reserved....
Open the catalog to page 5Board Level Color Control Table 3. Board Level Color Control for LUXEON XR-5050 HE PART NUMBER COLOR CONTROL Absolute Maximum Ratings Table 4a. Absolute maximum ratings for LUXEON XR-5050 HE 8up, 12up and 16up PARAMETER DC Forward Current Peak Pulsed Forward Current [1, 3] Maximum Working Voltage Operating Case Temperature at Tc point [1] Storage Temperature Reverse Voltage (Vreverse) LUXEON LEDs are not designed to be driven in reverse bias Notes for Table 4a: 1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable Tc temperature. 2. Residual...
Open the catalog to page 6Application Information Table 5a. Approbation for LUXEON XR-5050 HE 8up, 12up and 16up ITEM ENEC ENEC+ UL8750 (UL file no. E335118) RoHS Table 5b. Approbation for LUXEON XR-5050 HE 24up ITEM ENEC UL8750 (UL file no. E335118) RoHS Recommended Wire Table 6. Recommended Wire for LUXEON XR-5050 HE RECOMMENDED WIRE INSULATOR DIAMETER STRIP LENGTH DS413 LUXEON XR-5050 HE Product Datasheet 20260106 ©2026 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 7Characteristic Curves Spectral Power Distribution Characteristics Figure 1a. Typical normalized power vs. wavelength for 70CRI LUXEON XR-5050 HE 8up, 12up and 16up at 1050mA, Tc=25°C Figure 1b. Typical normalized power vs. wavelength for 70CRI LUXEON XR-5050 HE 24up at 1050mA, Tc=25°C DS413 LUXEON XR-5050 HE Product Datasheet 20260106 ©2026 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 8DS413 LUXEON XR-5050 HE Product Datasheet 20260106 ©2026 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 9Figure 3.Typical normalized power vs. wavelength for 90CRI LUXEON XR-5050 HE 24up at 1050mA, Tc=25°C DS413 LUXEON XR-5050 HE Product Datasheet 20260106 ©2026 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 10Light Output Characteristics Normalized Light Output [-] Tc [°C] Figure 4a. Typical normalized light output vs. Tc temperature for LUXEON XR-5050 HE 8up, 12up and 16up at 700mA Normalized Light Output [-] Tc [°C] Figure 4b. Typical normalized light output vs. Tc temperature for LUXEON XR-5050 HE 24up at 1050mA DS413 LUXEON XR-5050 HE Product Datasheet 20260106 ©2026 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 11Figure 5a. Typical normalized light output vs. forward current for LUXEON XR-5050 HE 8up, 12up and 16up at Tc=85°C Normalized Light Output [-] Forward Current [A] Figure 5b. Typical normalized light output vs. forward current for XR-5050 HE 24up at Tc=85°C DS413 LUXEON XR-5050 HE Product Datasheet 20260106 ©2026 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 12Efficacy Characteristics Normalized Efficacy [-] Tc [ °C ] Figure 6a. Typical normalized efficacy vs. Tc temperature for LUXEON XR-5050 HE 8up, 12up and 16up at 700mA Normalized Efficacy [-] Tc [ °C ] Figure 6b. Typical normalized efficacy vs. Tc temperature for LUXEON XR-5050 HE 24up at 1050mA DS413 LUXEON XR-5050 HE Product Datasheet 20260106 ©2026 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 1320 Pages
25 Pages
35 Pages
27 Pages
13 Pages
18 Pages
19 Pages
19 Pages
21 Pages
16 Pages
31 Pages
13 Pages
14 Pages
20 Pages
25 Pages
9 Pages
18 Pages
22 Pages
22 Pages
10 Pages
17 Pages
15 Pages
17 Pages
2 Pages
4 Pages
17 Pages
15 Pages
23 Pages
22 Pages
18 Pages
33 Pages
21 Pages
17 Pages
17 Pages
17 Pages
23 Pages
28 Pages
20 Pages
18 Pages
18 Pages
20 Pages
34 Pages
21 Pages
27 Pages
25 Pages
15 Pages
15 Pages
19 Pages
24 Pages
16 Pages
18 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
16 Pages
15 Pages
4 Pages
16 Pages
21 Pages
20 Pages
23 Pages
28 Pages
17 Pages
17 Pages
19 Pages
33 Pages
12 Pages
12 Pages
15 Pages
14 Pages
16 Pages
28 Pages
2 Pages
2 Pages
2 Pages
2 Pages
24 Pages
18 Pages
30 Pages
35 Pages
19 Pages
34 Pages
17 Pages
29 Pages
34 Pages
2 Pages
5 Pages
9 Pages
25 Pages
31 Pages
41 Pages