Catalog excerpts

LUXEON Rebel ANSI-1

LUXEON Rebel Illumination Portfolio The LUXEON Rebel Illumination Portfolio emitters in this datasheet deliver optimized combinations of light quality and light output needed for today's lighting applications. In addition to delivering specified Correlated Color Temperature and Color Rendering combinations, these emitters deliver the efficacy, lifetime and reliability that all LUXEON Rebel LEDs are renowned for. This document contains the performance data needed to design and engineer LUXEON Rebel based applications Features and Benefits Key Applications • Specified CCT & CRI combinations • Outdoor • ANSI compliant Quarter and Micro binning • Portable • Exceed ENERGY STAR® lumen maintenance requirements • High efficacy for sustainable design • More light delivered at operating temperature • Recognized under the Component Recognition Program of Underwriters

 Open the catalog to page 1
LUXEON Rebel ANSI-2

Table of Contents General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Average Lumen Maintenance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Environmental Compliance ....

 Open the catalog to page 2
LUXEON Rebel ANSI-3

General Information Product Nomenclature LUXEON Rebel Illumination emitters are tested and binned at 350mA, with current pulse duration of 20 ms. All characteristic charts where the thermal pad is kept at constant temperature (25°C typically) are measured with current pulse duration of 20 ms. Under these conditions, junction temperature and thermal pad temperature are the same. The LUXEON Rebel Illumination Portfolio is a series of power LED emitters designed for illumination. The part number designations for the LXML and LXM3 series is explained as follows: L X M L - A B C D and L X M 3 - A...

 Open the catalog to page 3
LUXEON Rebel ANSI-4

Product Selection for LUXEON Rebel 1 Philips Lumileds maintains a tolerance of ± 6 5% on luminous flux measurements and ± 2 on CRI measurements 2 Test current is 350mA for all LXML-Pxx1, LXM3-Pxx1 and LXMx-PWxx products LUXEON Rebel Datasheet DS63 20140721 ©2014 Philips Lumileds Lighting Company

 Open the catalog to page 4
LUXEON Rebel ANSI-5

Optical Characteristics LUXEON Rebel at Test Current Thermal Pad Temperature = 25°C 1 Test current is 350mA for all LXML-Pxx1, LXM3-Pxx1 and LXMx-PWxx products 3 Total angle at which 90% of total luminous flux is captured 4 Viewing angle is the off axis angle from lamp centerline where the luminous intensity is 1/2 of the peak value 5 All white products are built with Indium Gallium Nitride (InGaN) LUXEON Rebel Datasheet DS63 20140721 ©2014 Philips Lumileds Lighting Company

 Open the catalog to page 5
LUXEON Rebel ANSI-6

Electrical Characteristics Electrical Characteristics at 350mA, Thermal Pad Temperature = 25°C Table 3. Forward Voltage Vf [1] (V) Part Number Typ. Temperature Coefficient of Forward Voltage [2] (mV/°C) DVf / DTJ Typical Thermal Resistance Junction to Thermal Pad (°C/W) Ru J-C Notes for Table 3: 1. Philips Lumileds maintains a tolerance of ±0.06V on forward voltage measurements. 2. Measured between 25°C = TJ = 110°C at If = 350mA. Typical Electrical Characteristics at 700mA for LUXEON Rebel Thermal Pad Temperature = 25°C Table 4. Part Number Typical Forward Voltage Vf [1] (V) LXML-PW21 LXML-PW11...

 Open the catalog to page 6
LUXEON Rebel ANSI-7

Absolute Maximum Ratings Table 5. Parameter DC Forward Current (mA) Peak Pulsed Forward Current (mA) [3] Average Forward Current (mA) < 8000V Human Body Model (HBM) Class 3A JESD22-A114-E Operating Case Temperature at 350mA Storage Temperature Soldering Temperature Allowable Reflow Cycles Autoclave Conditions 121°C at 2 ATM 100% Relative Humidity for 96 Hours Maximum Notes for Table 5: 1. Proper current derating must be observed to maintain junction temperature below the maximum. 2. LUXEON Rebel LEDs are not designed to be driven in reverse bias. 3. Maximum Ratings of 1000mA forward drive current...

 Open the catalog to page 7
LUXEON Rebel ANSI-8

Reflow Soldering Characteristics Temperature profile for Table 7. Profile Feature Lead Free Assembly Average Ramp-Up Rate (Tsmaxto T ) 3°C / second max Preheat Temperature Min (Tsmin) 150°C Preheat Temperature Max (Tsmax) 200°C Preheat Time (ts tots ) 60 - 180 seconds Time Maintained Above Temperature (TL) (tL) 60 - 150 seconds Peak / Classification Temperature (Tp) 260°C Time Within 5°C of Actual Peak Temperature (tp) 20 - 40 seconds Ramp - Down Rate 6°C/second max Time 25°C to Peak Temperature 8 minutes max 1 AH temperatures refer to the application Printed Circuit Board (PCB), measured on...

 Open the catalog to page 8
LUXEON Rebel ANSI-9

Mechanical Dimensions Figure 1. Package outline drawing. Notes for Figure 1: 1. Do not handle the device by the lens—care must be taken to avoid damage to the lens or the interior of the device that can be damaged by excessive force to the lens. 2. Drawings not to scale. 3. All dimensions are in millimeters. 4. The thermal pad is electrically isolated from the anode and cathode contact pads. LUXEON Rebel Datasheet DS63 20140721 ©2014 Philips Lumileds Lighting Company.

 Open the catalog to page 9
LUXEON Rebel ANSI-10

Figure 2. Pad configuration. Note for Figure 2: 1. The thermal pad is electrically isolated from the anode and cathode contact pads. Figure 3. Solder pad layout. Notes for Figure 3: 1. The photograph shows the recommended LUXEON Rebel layout on Printed Circuit Board (PCB). This design easily achieves a thermal resistance of 7 K/W. 2. Application Brief AB32 provides extensive details for this layout. In addition, the .dwg files are available at www.philipslumileds.com and www.philipslumileds.cn.com. LUXEON Rebel Datasheet DS63 20140721 ©2014 Philips Lumileds Lighting Company.

 Open the catalog to page 10
LUXEON Rebel ANSI-11

Relative Spectral Distribution vs. Wavelength Characteristics LXM8-PW27 (2700K) at Test Current, Thermal Pad Temperature = 25°C Relative Spectral Power Distribution Wavelengt h (nm) Figure 4. Color spectrum of LXM8-PW27 emitter, integrated measurement. LXM3-PW81 (2700K) at Test Current, Thermal Pad Temperature = 25°C Relative Spectral Power Distribution Figure 5. Color spectrum of LXM3-PW81 emitter, integrated measurement. LUXEON Rebel Datasheet DS63 20140721 ©2014 Philips Lumileds Lighting Company.

 Open the catalog to page 11

All Philips Lumileds Lighting Company catalogs and technical brochures

  1. LUXEON Rubix

    41  Pages

  2. LUXEON Neo

    19  Pages

  3. Front fog

    2  Pages

  4. Stop/tail

    2  Pages

  5. DRL

    2  Pages

  6. LUXEON 5050

    16  Pages

  7. LUXEON XR-M

    14  Pages

  8. LUXEON 3030 HV

    20  Pages

  9. LUXEON XR-TX

    9  Pages

  10. LUXEON HR30

    18  Pages

  11. LUXEON XR-3020

    10  Pages

  12. SnapLED Xtreme

    15  Pages

  13. LUXEON Z UV

    15  Pages

  14. LUXEON M

    23  Pages

  15. LUXEON MZ

    22  Pages

  16. LUXEON Q

    18  Pages

  17. LUXEON Rebel ES

    33  Pages

  18. LUXEON Rebel

    21  Pages

  19. LUXEON TX

    17  Pages

  20. LUXEON Z

    17  Pages

  21. LUXEON Z ES

    23  Pages

  22. LUXEON K

    28  Pages

  23. LUXEON S

    20  Pages

  24. LUXEON XF-3535L

    18  Pages

  25. LUXEON 3014

    18  Pages

  26. LUXEON 3020

    20  Pages

  27. LUXEON 3535 2D

    34  Pages

  28. LUXEON 3535 HV

    21  Pages

  29. LUXEON 3535L

    27  Pages

  30. LUXEON 4014

    25  Pages

  31. SignalSure 250

    15  Pages

  32. SnapLED 150

    15  Pages

  33. LUXEON 3030 2D

    19  Pages

  34. LUXEON Altilon

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.