Superior lumen maintenance and corrosion resistance in punishing conditions LUXEON HR30 is specifically designed and tested for use in the most demanding environments and conditions. With upgraded packaging using ndustry-best materials, LUXEON HR30 is the only product in its class that provides robustness and long lifetime in high temperature and chemica vapor environments. The exceptional reliability and leading performance makes LUXEON HR30 an efficient solution for a wide variety of extreme and harsh indoor applications, like natatoriums. FEATURES AND BENEFITS PRIMARY APPLICATIONS Gold plated lead frame package with high reflectance SMC housing for exceptional reliability and lifetime in the most extreme conditions § y w y Proven resistant to chemical environments with IEC68-2-43 (15ppm), . DLOP <1 Oo/o, DuV <0.006 after 21 days lndoor Area Ll§htin8 Resistant to common chemical environments, such as high chlorine ^ , sulfur areas_ _ °utdoor 1/5th micro-color binning enables tight color control - Chemical Environments Targeted lifetime in excess of 100K hours at 150mA, Ts=105°C - industrial Lamps and Fixtures DS217 LUXEON HR30 Product Datasheet ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 1Table of Contents General Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Part Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Lumen Maintenance . . . . . . . . . . . . . . . . ....
Open the catalog to page 2General Product Information Product Test Conditions LUXEON HR30 LEDs are tested and binned with a 20ms monopulse of 150mA, at a junction temperature, Tj, of 25°C. Part Number Nomenclature Part numbers for LUXEON HR30 follow the convention below: L 1 3 0 – A A B B C C H R 0 0 0 0 0 Where: A A – designates ESD protection level (00=2kV and 0T=8kV) Therefore, the following part number is used for a LUXEON HR30 3000K 80CRI with an ESD protection level of 2kV: L 1 3 0 – 3 0 8 0 0 0 H R 0 0 0 0 0 Lumen Maintenance Please contact your local Sales Representative or Lumileds Technical Solutions Manager...
Open the catalog to page 3Performance Characteristics Product Selection Guide Table 1. Product performance of LUXEON HR30 at 150mA, T^S"^. 1. Total angle at which 90% of total luminous flux is captured. 2. Viewing angle is the off axis angle from the LED centerline where the luminous intensity is Vi of the peak value. DS217 LUXEON HR30 Product Datasheet 20160503 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 4Electrical and Thermal Characteristics Table 3. Electrical and thermal characteristics for LUXEON HR30 at 150mA, Tj=25°C. PART NUMBER FORWARD VOLTAGE [1] (Vf) MINIMUM TYPICAL TEMPERATURE COEFFICIENT OF FORWARD VOLTAGE [2] (mV/°C) TYPICAL THERMAL RESISTANCE—JUNCTION TO SOLDER PAD (°C/W) 14.0 Notes for Table 3: 1. Lumileds maintains a tolerance of ±0.1V on forward voltage measurements. 2. Measured between 25°C and 85°C. Absolute Maximum Ratings Table 4. Absolute maximum ratings for LUXEON HR30. PARAMETER DC Forward Current Peak Pulsed Forward Current LED Junction Temperature [1] (DC & Pulse) Operating...
Open the catalog to page 5Characteristic Curves Spectral Power Distribution Characteristics Figure 1a. Typical normalized power vs. wavelength for 70CRI LUXEON HR30 at 150mA, Tj=25°C. Figure 1 b. Typical normalized power vs. wavelength for 80CRI LUXEON HR30 at 150mA, Tj=25°C. DS217 LUXEON HR30 Product Datasheet 20160503 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 6Light Output Characteristics Figure 2. Typical normalized light output vs. junction temperature for LUXEON HR30 at 150mA. Figure 3. Typical normalized light output vs. forward current for LUXEON HR30 at Tj=25°C. DS217 LUXEON HR30 Product Datasheet 20160503 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 7Forward Current Characteristics Figure 4. Typical forward current vs. forward voltage for LUXEON HR30 at T.=25°C. Radiation Pattern Characteristics Figure 5. Typical radiation pattern for LUXEON HR30 at 150mA, T =25°C. DS217 LUXEON HR30 Product Datasheet 20160503 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 8Figure 6. Typical polar radiation pattern for LUXEON HR30 at 150mA, Tj=25°C. Product Bin and Labeling Definitions Decoding Product Bin Labeling In the manufacturing of semiconductor products, there are variations in performance around the average values given in the technical datasheet. For this reason, Lumileds bins LED components for luminous flux or radiometric power, color point, peak or dominant wavelength and forward voltage. LUXEON HR30 LEDs are labeled using a 4-digit alphanumeric CAT code following the format below: A B C D Where: A designates luminous flux bin (example: K=100 to 105...
Open the catalog to page 9Luminous Flux Bins Table 5 lists the standard luminous flux bins for LUXEON HR30 emitters. Although several bins are outlined, product availability in a particular bin varies by production run and by product performance. Not all bins are available in all CCTs. Table 5. Luminous flux bin definitions for LUXEON HR30. BIN H LUMINOUS FLUX [1] (lm) MINIMUM Notes for Table 5: 1. Lumileds maintains a tolerance of ±7.5% on luminous flux measurements. DS217 LUXEON HR30 Product Datasheet 20160503 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 10Figure 7. 3-step MacAdam ellipse illustration for Tables 6a-6e. Figure 8a. 1/5th color bin structure for LUXEON HR30 2700K. Table 6a. 3-step MacAdam ellipse color bin definitions for L130-27xxxxHR00000. NOMINAL CCT COLOR SPACE ELLIPSE ROTATION ANGLE, θ Single 3-step MacAdam ellipse Notes for Table 6a: 1. Lumileds maintains a tolerance of ±0.005 on x and y coordinates in the CIE 1931 color space. DS217 LUXEON HR30 Product Datasheet 20160503 ©2016 Lumileds Holding B.V. All rights reserved.
Open the catalog to page 1120 Pages
25 Pages
41 Pages
15 Pages
19 Pages
13 Pages
11 Pages
16 Pages
4 Pages
25 Pages
19 Pages
2 Pages
2 Pages
2 Pages
2 Pages
18 Pages
16 Pages
19 Pages
21 Pages
16 Pages
31 Pages
13 Pages
14 Pages
20 Pages
25 Pages
9 Pages
22 Pages
22 Pages
10 Pages
17 Pages
15 Pages
17 Pages
2 Pages
4 Pages
17 Pages
15 Pages
23 Pages
22 Pages
18 Pages
33 Pages
21 Pages
17 Pages
17 Pages
17 Pages
23 Pages
28 Pages
20 Pages
18 Pages
18 Pages
20 Pages
34 Pages
21 Pages
27 Pages
25 Pages
15 Pages
15 Pages
19 Pages
24 Pages
4 Pages
16 Pages
21 Pages
20 Pages
23 Pages
28 Pages
17 Pages
17 Pages
19 Pages
33 Pages
12 Pages
12 Pages
15 Pages
14 Pages
16 Pages
28 Pages
2 Pages
2 Pages
2 Pages
2 Pages
24 Pages
18 Pages
30 Pages
35 Pages
19 Pages
34 Pages
17 Pages
29 Pages
34 Pages
2 Pages
5 Pages
9 Pages
25 Pages
31 Pages
41 Pages