LUXEON H 50-2

LUXEON H 50-2
1 / 21 PagesView full catalog

LUXEON H 50-2

Product catalog summary
Introduction
The LUXEON H50-2 is a high voltage LED designed for high efficacy, color performance, and reliability, suitable for space-constrained and cost-sensitive retrofit bulbs and luminaires. It offers excellent color stability across temperature and current variations.
Features and Benefits
  • Enables the design of small, cost-effective luminaires with a simple driver.
  • Binned at 85°C and 40 mA with 3 and 5 SDCM color binning, supporting both 110V and 220V solutions.
  • Meets ENERGY STAR® lumen maintenance requirements.
  • Provides reliable performance in real-world applications.
Key Applications
  • Lamps
  • Specialty Lighting
General Information
The product is tested and binned at 40 mA with a 20 ms current pulse. The part number includes parameters for current design, CRI, and color temperature.
Average Lumen Maintenance Characteristics
LUXEON H50-2 products are projected to maintain 70% lumen output (L70) for over 36,000 hours at a drive current of 40 mA, with a Ts temperature ≤ 105°C.
Environmental Compliance
The product complies with RoHS and REACH directives, avoiding hazardous substances like lead, mercury, and cadmium.
Product Selection
Available models vary in nominal CCTs, CRIs, and luminous flux values, with a tolerance of ±6.5% on luminous flux and ±2 on CRI measurements.
Optical Characteristics
Details include color temperature, total included angle, and viewing angle for different CCTs.
Electrical Characteristics
Forward voltage and thermal resistance details are provided, with a tolerance of ±0.5% on forward voltage measurements.
Absolute Maximum Ratings
Specifies maximum performance parameters such as forward current, ESD sensitivity, junction temperature, and operating/storage temperatures.
Reflow Soldering Characteristics
Details on lead-free assembly temperature profiles, including ramp-up rates, preheat temperatures, and peak temperatures.
Mechanical Dimensions
Includes dimensions and handling notes, emphasizing not to handle the device by the lens.
Solder Pad Design
Recommended layout for PCB assembly is provided.
Relative Spectral Distribution vs. Wavelength Characteristics
Graphs showing color spectrum for different models at test current and thermal pad temperature.
Light Output Characteristics
Graphs illustrating relative light output versus thermal pad temperature and forward current.
Typical Forward Current Characteristics
Graph showing typical emitter efficacy versus forward current.
Typical Radiation Patterns
Spatial and polar radiation patterns for the product.
Packaging
Details on emitter pocket tape and reel packaging, including dimensions and orientation.
Product Binning and Labeling
Explanation of binning for luminous flux, color, and forward voltage to manage performance variations.
Specifications
Luminous Flux Bins: Categorized from B to Q, with photometric flux values ranging from 110 lm to 250 lm.
Forward Voltage Bins: Range from E to L, with voltages between 48.5 V and 52 V.
Color Bin Structure
Based on the CIE 1931 color space, includes 3-step and 5-step MacAdam Ellipse definitions for various color temperatures.
Company Information
Philips Lumileds is a leading LED provider with R&D centers in the US and the Netherlands, and production facilities in the US, Singapore, and Malaysia.
Disclaimer
The document includes a disclaimer about the accuracy of the information and reserves the right to make changes without notice.
See more

Catalog excerpts

LUXEON H 50-2-1

LUXEON H50-2 High Voltage LED Introduction The LUXEON® H50-2 delivers superior efficacy, color performance and reliability in a high voltage architecture that minimizes driver requirements making it an ideal solution for space constrained and cost sensitive retrofit bulbs and luminaires. With exceptional color stability over temperature and current, LUXEON H50-2 simplifies design while providing superior quality of light. This document contains the performance data and technical information needed to design and develop LUXEON H50-2 based solutions. • Enables design of small socket and cost sensitive luminaires with simple, efficient and small size driver • Is binned at 85°C and 40 mA with 3 and 5 SDCM color binning. 50V 2 watt LED flexibly supports 110V and 220V solutions. • Exceeds ENERGY STAR® lumen maintenance requirements • Delivers real-world in application performance and reliability. • Lamps • Specialty Lighting LUXEON H50-2 Datasheet DS110 ©2013 Philips Lumileds Lighting Company.

 Open the catalog to page 1
LUXEON H 50-2-2

Table of Contents General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Average Lumen Maintenance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 2
LUXEON H 50-2-3

General Information Product Nomenclature LUXEON H50-2 is tested and binned at 40 mA, with current pulse duration of 20 ms. All characteristic charts where the thermal pad is kept at constant temperature (85ºC typically) are measured with current pulse duration of 20 ms. Under these conditions, junction temperature and thermal pad temperature are the same. The part number designation is explained as follows: L X A C - A B C D Therefore 80 CRI products tested and binned at 2700K will have the part numbering scheme: LXAC-1827 Average Lumen Maintenance Characteristics Lumen maintenance for solid...

 Open the catalog to page 3
LUXEON H 50-2-4

Product Selection Product Selection for LUXEON H50-2 Thermal Pad Temperature = 85°C, Test Current = 40 mA Table 1. Nominal CCT Part Number Minimum Luminous Flux (lm) Typical Luminous Flux (lm) Note for Table 1: 1. Philips Lumileds maintains a tolerance of ± 6.5% on luminous flux and ± 2 on CRI measurements. Optical Characteristics Optical Characteristics for LUXEON H50-2 Thermal Pad Temperature = 85°C, Test Current = 40 mA Table 2. Nominal CCT 2700K 2700K Typ Total Included Angle [1] (degrees) u0.90V Typ Viewing Angle [2] (degrees) 2u 1/2 Notes for Table 2: 1. Total angle at which 90% of total...

 Open the catalog to page 4
LUXEON H 50-2-5

Electrical Characteristics Electrical Characteristics for LUXEON H50-2 Thermal Pad Temperature = 85°C, Test Current = 40 mA Table 3. Forward Voltage Vf [1] (V) Nominal CCT Typ. Temperature Coefficient of Forward Voltage [2] (mV/°C) DVF / DTJ Typical Thermal Resistance Junction to Thermal Pad (°C/W) Ru J-C Notes for Table 3: 1. Philips Lumileds maintains a tolerance of ± 0.5% on forward voltage measurements. 2. Measured between 25°C ≤ TJ ≤ 125°C at If = 40 mA. LUXEON H50-2 Datasheet DS110 20130716 ©2013 Philips Lumileds Lighting Company.

 Open the catalog to page 5
LUXEON H 50-2-6

Absolute Maximum Ratings Maximum Performance Kn <. . . . < 1000V Human Body Model (HBM) Class 2 JESD22-AI 14-B y < 400V Machine Model (MM) Class 2 JESD22-AI 15-B Operating Case Temperature at 40 mA -40°C - I I 8°C Soldering Temperature JEDEC 020c 260°C Allowable Reflow Cycles 3 100% Relative Humidity for 96 Hours Maximum Reverse Voltage (Vr) LUXEON H LEDs are not designed to be driven in reverse bias . Proper current derating must be observed to maintain junction temperature below the maximum. 2. For AC operation with a minimum of 50Hz. JEDEC Moisture Sensitivity LUXEON H50-2 Datasheet DSI 10...

 Open the catalog to page 6
LUXEON H 50-2-7

Reflow Soldering Characteristics Temperature Profile for Table 6. Table 6. Profile Feature Lead Free Assembly Average Ramp-Up Rate (Tsmax to Tp) Preheat Temperature Min (Tsmin) Preheat Temperature Max (Tsmax) Preheat Time (tsmin to tsmax) Time Maintained Above Temperature TL Time Maintained Above Time (t L) Peak / Classification Temperature (TP) Time Within 5°C of Actual Peak Temperature (tP) Ramp-Down Rate Time 25°C to Peak Temperature Note for Table 6: 1. All temperatures refer to the application Printed Circuit Board (PCB), measured on the surface adjacent to the package body. LUXEON H50-2...

 Open the catalog to page 7
LUXEON H 50-2-8

LASER MARK AREA (ISOLATED) 3X FIDUCIAL LOCATED FRONT SIDE SHOWN FOR REFERENCE ONLY 1.45±0.05 0.200 A B BACK SIDE METALIZATION CENTER TOLERENCE RELATIVE TO FRONT SIDE FIDUCIALS Figure 2. Notes for Figure 2: 1. Do not handle the device by the lens. Excessive force on the lens may damage the lens itself or the interior of the device. 2. Drawings not to scale. 3. All dimensions are in millimeters. 4. The thermal pad is electrically isolated from the anode and cathode contact pads. LUXEON H50-2 Datasheet DS110 20130716 ©2013 Philips Lumileds Lighting Company.

 Open the catalog to page 8
LUXEON H 50-2-9

Figure 3. Solder pad layout. Notes for Figure 3: 1. The photograph shows the recommended LUXEON H50-2 layout on Printed Circuit Board (PCB). 2. For more information on assembly and layout, please refer to Technical Note 106 (TN106). 3. The .dwg files are available at www.philipslumileds.com and www.philipslumileds.cn.com. LUXEON H50-2 Datasheet DS110 20130716 ©2013 Philips Lumileds Lighting Company.

 Open the catalog to page 9
LUXEON H 50-2-10

Relative Spectral Distribution vs. Wave length Characteristics Relative Spectra at Test Current,Thermal Pad Temperature = 85°C Figure 4. Color Spectrum of LXAC-18xx. Relative Spectra at Test Current,Thermal Pad Temperature = 85°C Figure 5. Color Spectrum of LXAC-19xx. LUXEON H50-2 Datasheet DSI 10 2013071 6 ©201 3 Philips Lumileds Lighting Company

 Open the catalog to page 10

All Philips Lumileds Lighting Company catalogs and technical brochures

  1. LUXEON Rubix

    41  Pages

  2. LUXEON Neo

    19  Pages

  3. Front fog

    2  Pages

  4. Stop/tail

    2  Pages

  5. DRL

    2  Pages

  6. LUXEON 5050

    16  Pages

  7. LUXEON XR-M

    14  Pages

  8. LUXEON 3030 HV

    20  Pages

  9. LUXEON XR-TX

    9  Pages

  10. LUXEON HR30

    18  Pages

  11. LUXEON XR-3020

    10  Pages

  12. SnapLED Xtreme

    15  Pages

  13. LUXEON Z UV

    15  Pages

  14. LUXEON M

    23  Pages

  15. LUXEON MZ

    22  Pages

  16. LUXEON Q

    18  Pages

  17. LUXEON Rebel ES

    33  Pages

  18. LUXEON Rebel

    21  Pages

  19. LUXEON TX

    17  Pages

  20. LUXEON Z

    17  Pages

  21. LUXEON Z ES

    23  Pages

  22. LUXEON K

    28  Pages

  23. LUXEON S

    20  Pages

  24. LUXEON XF-3535L

    18  Pages

  25. LUXEON 3014

    18  Pages

  26. LUXEON 3020

    20  Pages

  27. LUXEON 3535 2D

    34  Pages

  28. LUXEON 3535 HV

    21  Pages

  29. LUXEON 3535L

    27  Pages

  30. LUXEON 4014

    25  Pages

  31. SignalSure 250

    15  Pages

  32. SnapLED 150

    15  Pages

  33. LUXEON 3030 2D

    19  Pages

  34. LUXEON Altilon

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.