LUXEON H High Voltage (100V and 200V) LED Introduction LUXEON® H delivers superior lumen density, color performance and reliability in a high voltage LED on board architecture. For space constrained and cost sensitive retrofit bulbs and luminaires application, LUXEON H is the ideal solution as it minimizes system cost and space requirements through L2 solution and simpler driver. This document contains the performance data and technical information needed to design and develop LUXEON H based luminaires with products in 100V and 200V options in royal blue 2700K, 3000K and 4000K. • Provides compact source with single dome for directional lighting designs • Enables simplified small size solutions with compact, low cost driver • Ensures exceptional color stability over temperature and current • Delivers Freedom from CCT binning (3 SDCM), single flux bin and single Vf bin • Exceed ENERGY STAR® lumen maintenance requirements • High efficacy for sustainable design • Guaranteed performance at operating temperature • Downlights • Indoor area lighting • Lamps • Specialty Lighting LUXEON H Datasheet DS104 ©2013 Philips Lumileds Lighting Company.
Open the catalog to page 1Table of Contents General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Average Lumen Maintenance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 2General Information Product Nomenclature LUXEON H are specified at 40 mA (100V parts) and at 20 mA (200V parts), with junction temperature stabilized at 85°C. The part number designation is explained as follows: L XV a - P b c d - e f g h - i minimum CRI (8 = 80, 9 = 90, 0 = Royal Blue) color designation (R = Royal Blue, W = White) reserved for future proliferations L2 variant (0 for the L2 defined in this datasheet) number of emitters under the dome lens for color binning spec notation excluding 3 SDCM binning (5 for 5 SDCM, left empty with no notation Please see following part numbering scheme...
Open the catalog to page 3Average Lumen Maintenance Characteristics Lumen maintenance for solid-state lighting devices (LEDs) is typically defined in terms of the percentage of initial light output remaining after a specified period of time. Philips Lumileds projects that LUXEON H will deliver, on average, 70% lumen maintenance (L70) at 35,000 hours of operation at a forward current of up to 40 mA (LUXEON H 200V) and 80 mA (LUXEON H I 00V). This projection is based on constant current operation with junction temperature maintained at or below 35°C. This performance is based on independent test data, Philips Lumileds historical...
Open the catalog to page 4. Philips Lumileds maintains a tolerance of + 6.5% on luminous flux and + 2 on CRI measurements LUXEON H Datasheet DS104 201 3 I I 13 ©2013 Philips Lumileds Lighting Company
Open the catalog to page 5Product Selection Guide for LUXEON H (Royal Blue), . Philips Lumileds maintains a tolerance of ± 6.5% on luminous flux and ± 2 on CRI measurements. LUXEON H Datasheet DS104 201 3 I I 13 ©2013 Philips Lumileds Lighting Company. 5
Open the catalog to page 6Optical Characteristics LUXEON H at Test Current [1] (White) Junction Temperature = 85°C Table 6. Part Number Color Temperature CCT Typical Typical Total Included Angle [2] (degrees) u90V Typical Viewing Angle [3] (degrees) 2u ½ Notes for Table 6: 1. Test current is 40 mA for 100V LUXEON H products and 20 mA for 200V LUXEON H products. 2. Total angle at which 90% of total luminous flux is captured. 3. Viewing angle is the off axis angle from lamp centerline where the luminous intensity is ½ of the peak value. LUXEON H Datasheet DS104 20131113 ©2013 Philips Lumileds Lighting Company.
Open the catalog to page 7Electrical Characteristics Electrical Characteristics for LUXEON H Junction Temperature = 85°C Table 7. Forward Voltage Vf [1] (V) Part Number Typ. Temperature Coefficient of Forward Voltage [2] (mV/°C) DVF / DTJ Typical Thermal Resistance Junction to Thermal Pad (°C/W) Ru J-C Notes for Table 7: 1. Philips Lumileds maintains a tolerance of ± 0.5% on forward voltage measurements. 2. Measured between Tj=25°C and Tj =110°C. 3. Use total electrical power as the total heat dissipation. Typical Electrical Characteristics at High Current for LUXEON H Junction Temperature = 85°C Table 8. Part Number...
Open the catalog to page 8Absolute Maximum Ratings Table 9. Maximum Performance LXV8-PWxx-x014(-x) [White 4 Emitters 100V] LXV0-RW00-1014 [Royal Blue 4 Emitters 100V] Peak Forward Current (mA) ≤ 2000V Human Body Model (HBM) for LXV8-PWXX-0014 ≤4000V Human Body Model (HBM) for LXV8-PWXX-0024 Class 2 JESD22-A114-E ≤ 400V Machine Model (MM) Class B JESD22-A115-B LED Junction Temperature[1] Operating Case Temperature at Current Storage Temperature Wire Soldering Temperature Allowable Lead Reflow Cycles Autoclave Conditions 121°C at 2 ATM 100% Relative Humidity for 96 Hours Maximum LUXEON H LEDs are not designed to be driven...
Open the catalog to page 9Mechanical Dimensions Front View Side View Bottom View Figure 1. Package outline drawing for LXV8-PWxx-00x4. Notes for Figure 1: 1. Do not handle the device by the lens. Excessive force on the lens may damage the lens itself or the interior of the device. 2. All dimensions are in millimeters. 3. Dimension • Unless otherwise specified, all dimensions have a general tolerance of ± 0.10 mm. 4. Assembly Specifications • Mount components in accordance with ANSI/IPC-A-610 CLASS 2. • Boards must be functionally tested to verify all LED’s light. 5. Board traceability in 2D Matrix Barcode (on bottom surface...
Open the catalog to page 10Relative Spectral Distribution vs. Wavelength Characteristics LXV8-PW27 (2700K) at Test Current, Junction Temperature = 85°C 1 Relative Power Spectral Distribution, [-] Figure 2. Color spectrum of LXV8-PW27-x0xx, 2700K emitters, integrated measurement. LXV8-PW30 (3000K) at Test Current, Junction Temperature = 85°C 1 Relative Power Spectral Distribution, [-] Figure 3. Color spectrum of LXV8-PW30-x0xx, 3000K emitters, integrated measurement. LUXEON H Datasheet DS104 20131113 ©2013 Philips Lumileds Lighting Company.
Open the catalog to page 1120 Pages
25 Pages
41 Pages
15 Pages
19 Pages
13 Pages
11 Pages
16 Pages
4 Pages
25 Pages
19 Pages
2 Pages
2 Pages
2 Pages
2 Pages
18 Pages
16 Pages
19 Pages
21 Pages
16 Pages
31 Pages
13 Pages
14 Pages
20 Pages
25 Pages
9 Pages
18 Pages
22 Pages
22 Pages
10 Pages
17 Pages
15 Pages
17 Pages
2 Pages
4 Pages
17 Pages
15 Pages
23 Pages
22 Pages
18 Pages
33 Pages
21 Pages
17 Pages
17 Pages
17 Pages
23 Pages
28 Pages
20 Pages
18 Pages
18 Pages
20 Pages
34 Pages
21 Pages
27 Pages
25 Pages
15 Pages
15 Pages
19 Pages
24 Pages
4 Pages
16 Pages
21 Pages
20 Pages
28 Pages
17 Pages
17 Pages
19 Pages
33 Pages
12 Pages
12 Pages
15 Pages
14 Pages
16 Pages
28 Pages
2 Pages
2 Pages
2 Pages
2 Pages
24 Pages
18 Pages
30 Pages
35 Pages
19 Pages
34 Pages
17 Pages
29 Pages
34 Pages
2 Pages
5 Pages
9 Pages
25 Pages
31 Pages
41 Pages