Overview: The document provides detailed specifications and operational guidelines for the MLS-3751L-PE and MLS-3781L-PE portable laboratory autoclaves, designed for use in biotechnology, pharmaceutical, and clinical laboratories. These autoclaves are self-contained, energy-saving, and suitable for a wide range of sterilization applications.
Specifications:
  • Model Numbers: MLS-3751L-PE (50 liters) and MLS-3781L-PE (75 liters).
  • External Dimensions: MLS-3751L-PE - 478 x 632 x 748 mm; MLS-3781L-PE - 478 x 632 x 965 mm.
  • Internal Dimensions: Diameter x Depth - 370 x 415 mm (MLS-3751L-PE) and 370 x 630 mm (MLS-3781L-PE).
  • Volume: 50 liters for MLS-3751L-PE and 75 liters for MLS-3781L-PE.
  • Net Weight: Approximately 61 kg for MLS-3751L-PE and 71 kg for MLS-3781L-PE.
  • Performance: Maximum pressure of 0.240 Mpa, sterilization temperature range of 115˚C to 135˚C, and culture media melting temperature range of 60˚C to 114˚C.
Features:
  • 12 pre-set programs with a user-friendly control panel.
  • Independent programming for custom settings.
  • Microprocessor temperature control with a precision of +2˚C/-0˚C.
  • Reduced cooling time through adjustable exhaust process valve.
  • Air vent control for automatic release post-sterilization.
  • Four selectable courses: Sterilizing, Sterilizing/Keep Warm, Melting/Keep Warm, and Sterilizing Unwrapped Instruments.
User Safety:
  • Conforms to IEC standards with a cover opening temperature set to 65˚C or less.
  • Equipped with safety devices including pressure safety valve, over-temperature limiter, over-pressure limiter, anti-scorch limiter, door interlock, and current fuse.
Design and Construction:
  • Exterior and interior made of stainless steel (SUS 304).
  • Includes stainless steel baskets and a 2-liter polyethylene exhaust tank.
  • Features a swing-up lid and hand-pull system for easy access.
Operational Guidelines:
  • Operating time varies based on conditions; liquid sterilization takes longer than instrument sterilization.
  • Settable ranges for sterilizing temperature, time, and exhaust temperature.
Contact Information:
  • Address: Nijverheidsweg 120, 4879 AZ Etten-Leur, Netherlands.
  • Phone: +31 (0) 76 543 3839
  • Website: www.phchd.com/eu/biomedical
See more

Catalog excerpts

MLS-3751L-PE Portable labaratory autoclave EN-1

Portable Laboratory Autoclaves Convenient sterilisation on demand offers great flexibility MLS series top-loading autoclaves are a popular method of sterilisation for today’s research laboratories. Self-contained and easy to use, these reliable energy-saving autoclaves are ideal for a wide range of applications. MLS-3751L-PE Pre-set Programs User Friendly Design User Safety These units offer a total of 12 pre-set programs to choose from on a simple-tooperate control panel with lighten temperature/time indicators. They also allow for independent programming for users to set their own programs. A swing-up lid provides effortless access for loading and unloading test tubes, flasks and lab instruments. The hand-pull system enables easy opening/closing by gripping with one hand. Conforming to the require­ ments of IEC standards, when using sterilising liquid the temperature when opening the cover is set to 65˚C or less. Exhaust holes on the side and the cooling fan under the chamber, offer optimum cooling and sterilising efficiency. Variable Applications Reduced Cooling Time Our equipment is designed to meet good laboratory practice criteria in biotechnology, pharmaceutical, and clinical laboratories. For safe use of the product, precautions and operating instructions are given by voice guidance. A constant open/close interval for the exhaust process valve enables selection of the exhaust rate for steam inside the chamber to enable cooling in a shorter time

 Open the catalog to page 1
MLS-3751L-PE Portable labaratory autoclave EN-2

MLS-3751L-PE Microprocessor temperature control Sterilizing temperature is controlled to within +2°C/-0°C of the set temperature in the range of 115°C to 135°C. Reduced Cooling Time A constant open/close interval (with 5-step adjustment) for the exhaust process valve enables selection of the exhaust rate for steam inside the chamber to enable cooling in a shorter time while reducing exhaust time and preventing boiling over of sterilizing liquid. Air vent control Can be set to allow automatic release after sterilizing is completed. Model Number Appearance and specifications are subject to change...

 Open the catalog to page 2

All PHC Europe B.V. / PHCbi catalogs and technical brochures

  1. MPR-514(R)-PE

    2  Pages

  2. MPR-1014R-PE

    2  Pages

  3. TwinGuard

    12  Pages

Archived catalogs

  1. ULT VIP

    12  Pages

  2. MIR-H163-H263

    2  Pages

  3. MDF-U4186S-PE

    2  Pages

  4. MBR-705GR

    2  Pages

  5. MDF-U7386S-PE

    2  Pages

  6. MDF-C8V1-PE

    2  Pages

  7. MDF-U731M

    2  Pages

  8. MDF-U5386S-PE

    2  Pages

  9. MDF-U3386S-PE

    2  Pages

  10. MDF-U33V

    2  Pages

  11. MDF-U4186S

    2  Pages

  12. MDF-U55V-PE

    2  Pages

  13. MDF-U74V

    2  Pages

  14. MDF-U500VX

    2  Pages

  15. MDF-U700VX-PE

    2  Pages

  16. Twinguard

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.