PHCbi Cooled Incubators have been recognised as exceptional units suitable for a wide range of applications. These incubators offer precise, repeatable control of programmable temperatures and lighting patterns which are essential to biological research and environmental studies. Model Range: PHC Europe A Member of PHC Group
Open the catalog to page 1COOLED INCUBATORS PURE PERFORMANCE MIR Cooled Incubators 123 litres Incubator Quality control and testing is an important aspect of pharmaceutical development. With our cooled incubators, achieve optimal temperature configuration for a variety of protocols, including QA / QC, microbiology and stability conditioning.
Open the catalog to page 2Combining flexible temperature (H), light on/off (L) and time control (T), a maximum 12-step plus constant operation or max. 12-step repeating operation can be programmed according to the experimentation requirements. A program can be set to repeat for a minimum of one time to a maximum of 98 times or continuous repeat. Program input is simple and the incubator accommodates a range of diversified experimentation requirements, proving ideal for experimentation during night time and holidays, experimentation that requires settings to be changed, microorganism culture and preservation. The Cooled...
Open the catalog to page 3Condensation prevention (MIR-554 only) A humidity reduction mode helps reduce inner chamber condensation that may occur during high temperature operation. Prevents medium from dessication (MIR-154, 254 only) A DC fan is designed to be aimed obliquely upward to prevent direct air flow contacting samples. This reduces medium drying byapprox. 50% in MIR-154, and by approx. 15% in MIR-254. The Cooled Incubators are crafted with a comfortable rounded corner design and offer a reversible door for a choice of left- or right-hand door opening. Low vibration setting is also available depending on the...
Open the catalog to page 4Models: MIR-154-PE I MIR-254-PE I MIR-554-PE Chamber pull-down/pull-up characteristics Chamber pull-down/pull-up characteristics (Ambient temperature 20°C Power source: AC100V/50Hz) (Ambient temperature 20°C Power source: AC100V/50Hz) Chamber thermal load 225W 25 *The data 580 shown above are taken with the flu *Characteristics may vary depending on the p 450 200 Unit :Chamber mm thermal load 100W Chamber thermal load 200W Time (Hr) Chamber Chamber thermal loadtherma 300W *The data shown above are taken with the fluorescent lamp off. *Characteristics may vary depending on the product or operating...
Open the catalog to page 5Model Number Door window blanking plate Appearance and specifications are subject to change without notice. 1) Exterior dimensions of main cabinet only, excluding handle and other external projections - See dimensions drawings on website for full details 3) Nominal value. Background noise 20dB * Complies with Art. 11, Annex III of F-Gas Regulation (EU) No 517/2014. Contains fluorinated greenhouse gases. A Member of PHC Group VERSION 0462025 Eikdonk 1 | 4825 AZ Breda | Netherlands T: +31 (0) 76 543 3833
Open the catalog to page 620 Pages
16 Pages
16 Pages
28 Pages
36 Pages
56 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
14 Pages
60 Pages
2 Pages
2 Pages
12 Pages
16 Pages
12 Pages
2 Pages
7 Pages
4 Pages
4 Pages
7 Pages
12 Pages
2 Pages
28 Pages
6 Pages
16 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
12 Pages
2 Pages
2 Pages
6 Pages
8 Pages