
ULT & CRYOGENIC compressor compressor REFRIGERATION compressor HYBRID FrostLess HYBRID INCUBATION Integrated shelves (*option) Integrated *Standard for Model MCO-171AICUVD Integrated shelves Integrated shelves Easy-to-Use 11 hours 180°C Dry Heat Sterilization Model PHCbi’s Dry Heat Sterilization CO2 incubator with inCu-saFe germicidal interior. The heat dissipation and maximum current lowering functions allow two units to be be stacked on top of each other with one delivering dry heat sterilization while the other is used for culture purposes. MCO-171AICD / MCO-171AICUVD UV-LED lamp delivers long-lasting performance Saves replacing germicidal lamp time and reduces running costs Integrated Shelf Supports improve cleaning and increases culture capacity An UV-LED germicidal lamp is positioned in the rear duct and switches on to sterilise the water used in the humidifiying pan. The lamp does not use harmful mercury and delivers better sterilization compared to conventional UV lamps. * The use of a long-lasting LED lamp eliminates regular replacement of germicidal lamps even with 30 door openings per day. Cleaning the chamber is easier and more efficient as the shelf support section minimises the interior items used. It is now possible to place 20 100ø mm Petri dishes on each tray. (Based on internal test results) Stacking for work efficiency Improved Usability Fiberglass insulation minimises heat dissipation from the incubator. This allows one unit to be used for dry-heat sterilization while the other continues normal incubation when two incubators are stacked. The new structural design enabling quick in-chamber temperature rising and reducing temperature distribution variations provides dry heat sterilization lasting approximately 11 hours. The full-colour LCD touch panel allows efficient management of the functions. The USB port next to the panel enables transferring logged data to memory devices. The new designed incubator has an improved easy-to-grasp handl
Open the catalog to page 1Dry Heat sterilizing CO2 Incubators 1) Exterior dimensions of main cabinet only, excluding handle and other external projections. 2) Ambient temperature 23°C, setting 37°C, CO2 5%, no load. 3) Dry heat sterilisation can be performed only for the chamber and inner attachments with standard specifications, not for any other objects. 5) If stacking two incubators, make sure the double-stacking dedicated securing hardware and spacer are used. 6) Only for the Data acquisition system MTR-5000 user. MCO-171AICD series can only be fitted with one communications interface. Advanced product design The...
Open the catalog to page 220 Pages
16 Pages
16 Pages
6 Pages
28 Pages
36 Pages
56 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
32 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
14 Pages
60 Pages
2 Pages
2 Pages
12 Pages
16 Pages
12 Pages
2 Pages
7 Pages
4 Pages
4 Pages
7 Pages
12 Pages
2 Pages
28 Pages
6 Pages
16 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
12 Pages
2 Pages
2 Pages
6 Pages
8 Pages