Overview of Low-Temperature Storage Systems
Ensuring a constant temperature range below a critical threshold is crucial for low-temperature storage systems. For living cells, the critical temperature is below -130ºC, and maintaining temperatures between -150ºC to -196ºC is ideal.

Panasonic Biomedical's Innovations
Panasonic Biomedical Sales Europe B.V. is a leader in the European Ultra Low Temperature market, known for innovations like VIP panels, Cool Safe® compressors, and the world's first -152ºC ULT freezer. Their freezers incorporate high-efficiency oil separators to prevent compressor damage and ensure stable ultra-low temperatures.

Cryopreservation Techniques
Cryopreservation is essential for preserving biological materials without altering them. It involves storage at extremely low temperatures to halt deterioration. Panasonic's freezers are designed to minimize cross-contamination risks associated with liquid nitrogen.

Custom BioGenic Systems' Isothermal Freezers
Custom BioGenic Systems (CBS) offers isothermal freezers that eliminate cross-contamination risks by using a patented liquid nitrogen jacket. This design provides uniform storage temperatures in the -190ºC range without direct contact with liquid nitrogen.

Advantages of Isothermal Design
The isothermal design ensures uniform temperature distribution, reduces cold air loss, and improves visibility during access. It also enhances user safety by eliminating liquid nitrogen contact.

Compliance and Capacity
These systems comply with the Medical Device Directive 93/42/EEC: 1993 Class IIA and offer various models with capacities ranging from 9,100 to 45,000 2ml vials. They feature auto-fill and monitoring systems for sample security.

Comparison of Storage Solutions
The document compares different storage solutions, highlighting the benefits of dry vapor storage over traditional liquid nitrogen storage, particularly in terms of cross-contamination risk and temperature stability.
See more

Catalog excerpts

Cryopreservation without crosscontamination risk-1

Cryopreservation without crosscontamination risk Biological materials such as cells or tissue samples will naturally change and deteriorate over time. In order to properly preserve them for later study, some means of halting these processes must be used that will not change the biological materials. The most effective means of preserving biological materials is cryopreservation – storage at extremely low temperatures. Cryopreservation has been used for decades throughout the biological and bio-medical research community. he most important element of a lowtemperature storage system is ensuring a constant range of temperatures below a minimum critical threshold. The upper limit of the range should be well below the critical temperature for the material to allow for any effects or compromise during stocking and retrieval activities. For example, the critical temperature for living cells is below -130ºC; therefore, maintaining cells in a liquid nitrogen freezer at -150ºC to -196ºC is ideal. Panasonic Biomedical Sales Europe B.V. has established a worldwide reputation as a manufacturer of high quality medical equipment over the past forty years. In this period we became the leader in the European Ultra Low Temperature market. In this field Panasonic has set the standard in many aspects. VIP panels, Cool Safe® compressors and the world’s first -152ºC ULT freezer. Where Panasonic took the initiative, the others followed. Together with the high standard of service we deliver it makes us a major player in the biomedical market. refrigeration system enhances reliability of long-term preservation. With a powerful low noise design afforded by traditional ultra-low temperature technology, this freezer delivers durable, stable cooling. Why freeze to -152ºC? Recrystallization mechanism Cubic crystal Compressors continuously repeat highly compressed operations, so lubricant oil is essential to prevent abrasion and seizure. But when lubricant oil circulates in the refrigeration circuit, piping becomes clogged and results in compressor damage. Incorporating a high-efficiency oil separator, Panasonic -150ºC freezers effectively separate lubricant oil from refrigerant, offering a stable ultra-low temperature environment. Highly efficient compressors have been specially developed and incorporated in -150ºC freezing units. A refrigeration circuit with the Cool Safe® compressor cascade Panasonic Biomedical Journal Hexagonal crystal

 Open the catalog to page 1
Cryopreservation without crosscontamination risk-2

Panasonic Biomedical Journal

 Open the catalog to page 2
Cryopreservation without crosscontamination risk-3

Liquid nitrogen is like all liquids, a possible transporter of contaminants. Transmission of biological contaminants between samples and possible leakage of liquid nitrogen into the vials when submerged are just some of the concerns that can be eliminated with an Isothermal liquid nitrogen dry storage freezer from Custom BioGenic Systems (CBS). When in the 1980’s HIV/AIDS was first recognized, storage in liquid became an increasing concern. These concerns have been scientifically demonstrated and are documented in papers such as from Teddar et al.,1995, Fountain et al.,1997 and Bielanski et al.,2000....

 Open the catalog to page 3
Cryopreservation without crosscontamination risk-4

With a minimal temperature gradient, the full internal volume of each freezer is available for storing samples at liquid nitrogen temperatures making the most efficient use of available capacity. CBS Isothermal Freezers also provide added user safety by eliminating contact or splashing of liquid nitrogen. • Medical Device Directive 93/42/EEC: 1993 Class IIA. • Choice of 8 models offering capacities between 9,100 and 45,000 2ml vials (maximum). • All models feature the Series 2301 Auto-fill and Monitor System providing sample security and ease of operation. • A wide selection of inventory systems...

 Open the catalog to page 4

All PHC Europe B.V. / PHCbi catalogs and technical brochures

  1. MPR-514(R)-PE

    2  Pages

  2. MPR-1014R-PE

    2  Pages

  3. TwinGuard

    12  Pages

Archived catalogs

  1. ULT VIP

    12  Pages

  2. MIR-H163-H263

    2  Pages

  3. MDF-U4186S-PE

    2  Pages

  4. MBR-705GR

    2  Pages

  5. MDF-U7386S-PE

    2  Pages

  6. MDF-C8V1-PE

    2  Pages

  7. MDF-U731M

    2  Pages

  8. MDF-U5386S-PE

    2  Pages

  9. MDF-U3386S-PE

    2  Pages

  10. MDF-U33V

    2  Pages

  11. MDF-U4186S

    2  Pages

  12. MDF-U55V-PE

    2  Pages

  13. MDF-U74V

    2  Pages

  14. MDF-U500VX

    2  Pages

  15. MDF-U700VX-PE

    2  Pages

  16. Twinguard

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.