UV-VISIBLE SPECTROPHOTOMETER PRODUCT BROCHURE Analytical Instruments for Science
Open the catalog to page 1Spectrophotometer Liquid IQ/OQ Qualification Package 26
Open the catalog to page 2Since its development in the 1950’s the UV-Visible Spectrophotometer has evolved into an accurate and reliable analytical tool and it has become one of the most utilised instruments in today’s scientific laboratory. UV-Visible absorption of the analayte corresponds to both established analytical technique used extensively in many excitation of valence electrons and excitation of industry sectors including Environmental Analysis, electrons in different atomic orbitals. Pharmaceutical Testing, Food and Beverage Production UV-Vis Spectroscopy is an effective technique for both to name but a...
Open the catalog to page 3Reference beams by means of a beam splitter using a The UV-Vis Spectrophotometer is the analytical separate detector for each. Split beam instruments have instrument used for the UV-Vis spectroscopic analysis. a reference detector housed inside the instrument optics offering the advantage of optical stability as in configurations however most can be categorized into double beam spectroscopy whilst using the single beam either single beam, split beam or double beam types measurement technique. depending on the design of their optical system. Such types of instrument comprise the following...
Open the catalog to page 4The T60 is a high performance compact split beam spectrophotometer with a fixed 2nm spectral bandwidth. The T60 range consists of two models: T60U (UV-Visible) operating within a wavelength range of 190 - 1100nm. T60V (Visible) operating within a wavelength range of 325 - 1100nm. The instrument has a switched mode power supply accepting voltages in the range of 95 - 240V AC and supplied with either universal pathlength 5 cell changer or fixed path length 8 cell changer as standard. The T60 delivers the functionality and accuracy of an advanced instrument at an affordable price. F E AT U R E...
Open the catalog to page 6OPTICAL SYSTEM & COMPONENTS High quality optical components ensure reliable analytical data with low stray light achieved using very low noise electronic circuits. Deuterium and tungsten light sources deliver superior stability across the full wavelength range. Both types of lamp have self timers and are inexpensive and easy to replace when required. The monochromator is completely sealed and the optical surfaces can be easily cleaned to maintain optimum reflectivity over the lifetime of the instrument. A maintenance free high resolution direct stepper drive positions the grating precisely,...
Open the catalog to page 7Optical system Split beam ratio Split beam ratio Scan speed Wavelength range Wavelength accuracy Wavelength reproducibility Spectral bandwidth Photometric mode Transmittance, Absorbance, Energy Transmittance, Absorbance, Concentration Photometric range Photometric accuracy Photometric reproducibility Photometric noise Baseline flatness Baseline stability Stray light Standard Functionality Photometric Measurement (Quantitative, Multi-wavelength, Spectrum and Kinetic measurements with program cards) Photometric & Quantitative Measurement Silicon photo diode Silicon photo diode Light source...
Open the catalog to page 8The T70 is a high performance split beam spectrophotometer available with a fixed (2nm) or variable (0.5, 1, 2, 5nm) spectral bandwidth, which is innovative in terms of instrument application, mechanical and optical design, electronic control and software whilst retaining features that are well established and accepted through the industry. The T70 series of UV-Visible Spectrophotometers are able to carry out photometric measurement, spectrum scans, quantitative determination and DNA/Protein analysis. When interfaced to a PC using the UV-Win software, many more features are available...
Open the catalog to page 10OPTICAL SYSTEM & COMPONENTS High quality optical components ensure reliable analytical data with low stray light achieved using very low noise electronic circuits. The split beam ratio optics ensures good optical stability. Pre-aligned Deuterium and tungsten light sources deliver superior stability across the full wavelength range. Both types of lamps are inexpensive and easy to replace when required. The modular design allows easy access to all optical surfaces which can be easily cleaned to maintain optimum reflectivity over the lifetime of the instrument.
Open the catalog to page 11Specifications Instrument Type Optical System Split beam ratio Split beam ratio Scan Speed Wavelength Range Wavelength Accuracy Wavelength Reproducibility Spectral Bandwidth Photometric Mode Transmittance, Absorbance, Energy Concentration Transmittance, Absorbance, Energy Concentration Photometric Range Photometric Accuracy Photometric Reproducibility Photometric Noise Baseline Flatness Baseline Stability Stray light Standard Functionality Photometric, Quantitative, Spectrum and DNA measurements. Photometric, Quantitative, Spectrum and DNA measurements. Cell Holder Automatic 8 Cell changer...
Open the catalog to page 12The T80 is a high performance double beam spectrophotometer available with a fixed (2nm) or variable (0.5, 1, 2, 5nm) spectral bandwidth, which is innovative in terms of instrument application, mechanical and optical design, electronic control and software whilst retaining features that are well established and accepted through the industry. The T80 series of UV-Visible Spectrophotometers are able to carry out photometric measurement, spectrum scans, quantitative determination and DNA/Protein analysis. When interfaced to a PC using the UV-Win software, many more features are available...
Open the catalog to page 14OPTICAL SYSTEM & COMPONENTS High quality optical components ensure reliable analytical data with low stray light achieved using very low noise electronic circuits. The double beam optics ensure good optical stability. Pre-aligned Deuterium and Tungsten light sources deliver superior stability across the full wavelength range. Both types of lamps are inexpensive and easy to replace when required. The modular design allows easy access to all optical surfaces which can be easily cleaned to maintain optimum reflectivity over the lifetime of the instrument.
Open the catalog to page 15All PG INSTRUMENTS LIMITED catalogs and technical brochures
-
CCD METAL ANALYSER
9 Pages
-
UV-Win6
102 Pages
-
GC650
12 Pages
-
Tintration System
4 Pages
-
FP902
4 Pages
-
pH-Conductivity Meter
2 Pages
-
UV-WinGLP
4 Pages
-
T110+/T112+
2 Pages
-
T92+
4 Pages
-
T85
4 Pages
-
T80
4 Pages
-
T70
4 Pages
-
T75
4 Pages
-
T60
4 Pages
-
C30/C30M
4 Pages
-
Micron-Mist
2 Pages
-
AA990F
2 Pages
-
FP910
4 Pages
-
AF420
4 Pages
-
PG990
2 Pages
-
AA500
4 Pages
-
ICP 5000
4 Pages
-
AA500 IQ/OQ Kit
2 Pages
-
Atomic Fluorescence
2 Pages
-
Adjustable Nebuliser for AAS
1 Pages
-
Spectroscopy Brochure
43 Pages
-
UV IQ/OQ
2 Pages
-
FLAME PHOTOMETER
4 Pages
Archived catalogs
-
Gas Chromatograph
2 Pages
-
Flame Photometer
2 Pages
-
Atomic Absorption
4 Pages
-
Spectrophotometer
44 Pages