Catalog excerpts
ELEMENTAL SPECTROSCOPY PRODUCT BROCHURE Analytical Instruments for Science
Open the catalog to page 1AA500 Atomic Absorption Spectrometer 8 AA990F Atomic Absorption Spectrometer 18 Atomic Absorption Spectrometer Qualification Kit 24 Atomic Fluorescence Spectroscopy 26 AF402 Simultaneous Atomic Fluorescence Spectrometer 28
Open the catalog to page 2Atomic Absorption Spectroscopy Since its development in the 1950’s the Atomic Absorption Spectrometer (AAS) has evolved into an accurate and reliable analytical tool used extensively in today’s modern laboratory. AAS is an analytical procedure for the Qualitative and in the form of an aerosol which is converted to an Quantitative determination of chemical elements in a atomic vapour, atoms present in the vapour are then sample. The technique is based on the Lambert-beer raised from their ground state to their excited state. The principle which states that the absorbance of a solution atoms...
Open the catalog to page 4Elements – Periodic Table Group Period Graphite Analysis There are three main techniques for AAS analysis each The graphite analysis technique uses an assembly having their strengths and weaknesses depending on containing a graphite tube to replace the burner. This the type of analysis required. There are a number of technique is used to analyse very low levels with low factors to consider when deciding which technique will sample volumes. Although the detection limit is very low, suit the application. For example: the precision is almost always higher than that of the flame technique. The...
Open the catalog to page 5Detection limits Element Air/LPG mg/l(ppm) Graphite µg/l(ppb) Vapour µg/l(ppb)
Open the catalog to page 6E r EW D E fo is N RA ABLion alys PG IL at an U A om nt AV Aut leme ll -e Fu lti u m The AA500 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications including: l Agricultural The versatile instrument is available in three configurations: AA500F – The instrument is equipped with a flame atomiser only. The positioning of which is fully controlled by the embedded computer system and AA Win software. Three flame options are...
Open the catalog to page 8AA500 F E AT U R E S & F U N C T I O N S l Embedded PC system built into the instrument as standard on all configurations. Pre-installed AAWin3 software, user manuals, cook book and Windows operating system. l AAWin3 software provides full control of the instrument and autosampler with easy method change for each technique. Now GLP compliant. l Automatic 8 Hollow Cathode lamp turret controlled continued Air/Acetylene l The Air/Acetylene flame uses a 100mm single slot burner for the standard configuration. l The high sensitivity (Cu 2ppm >0.280abs) is due to the inert adjustable nebuliser...
Open the catalog to page 9Safety Features l Pressure monitoring for all gases l Burner Identification l Flame sensor l Drain Trap level Sensor l Gas Leak Detector l Over Pressure in Premix l Safety Cut off Switch l Pyrolytically coated graphite tubes are used as standard and are manufactured to improve performance as well as increase the analytical life. l Platform graphite tubes are supplied as standard and will accept volumes up to 20µl. Non-platform graphite tubes are also available as an optional extra. l Up to 10 heat stages are available for the programming of the graphite atomiser. These can be set and stored...
Open the catalog to page 10AAWin3 Software is a powerful and intuitive software product designed to allow control and data acquisition from the PG Instruments AA500 series Atomic Absorption Spectrometer. The AAWin3 software allows the Analyst to control all aspects of their analytical method whilst providing an extensive range of tools for data collection, storage The software interface consists of three key work- areas, whilst having toolbars to access many others. These work areas allow the user to view real-time signal acquisition, up-to-date display of calibration curves and a flexible, sample table. The AAWin3...
Open the catalog to page 11Full Automation for Multi-Element Analysis A Ensure optimal peak position at the chosen analytical line by scanning the emissions spectra. S*ti» i.ufiwrtjn IT *lh(j<i tun.* uqual i_n LOIL- JIB*^ i m *]Jiptt concaniEMM unit cV tie stunrJeid. Start ID »tie eteftng poind tiw . IHIIJ- y puinl ul Irw vwnal NO. Conertan Me*ad|Q: |L'QIIL]'<TKHI Qjive r AUID Ungrate EqucHcr.^ Foclnr Each stage of analysis setup is made quick and simple by means of the Sample Wizard. Obtain reliable and accurate results by using the Energy control feature to manually optimise atomiser Use the Auto-balance feature to...
Open the catalog to page 12Specifications Spectrometer System Wavelength range Light Source Hollow cathode lamp (HCL), Deuterium Arc lamp (D2) Square Wave Pulse Modulation frequency 100hz Self reversal (SR) background, 400hz Deuterium Arc (D2) background Monochromator Grating 1800 grooves/mm diffraction grating Blazed Wavelength Scan mode Photometric Type Single Beam Wavelength Accuracy Wavelength Resolution Wavelength Reproducibility Baseline Stability Background Correction Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs Flame Analysis Flame Types Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG)...
Open the catalog to page 13Specifications Spectrometer System Data Processing PC System Embedded PC, Windows Professional Operating System Operating Program Analytical Methods Flame AA, Flame AE, Graphite Furnace, Hydride Generation Readout Mode Continuous, Manual, Peak Height, Peak Area Multi-Standard Calibration, Standard Addition, Interpolation Data Storage Analytical results, instrument and measurement parameters, signal profile, calibration curve Power Requirements Main Unit Graphite Power Supply 220Vac 50/60hz Instantaneous power 5KW Current rating?? Dimensions Main unit Graphite Power Supply Main unit Main...
Open the catalog to page 14Accessories Autosampler (500-004) The AS500 Autosampler is an accessory specifically designed for the AA500 Atomic Absorption Spectrometer. The AS500 can be used to automatically introduce standard and unknown samples to the atomiser for analysis. It can be used with both flame and graphite furnace instruments. Flame Analysis l 38 sample positions (6 for standard samples, 32 for unknown samples). l Sample vial size 6ml l Standard sample vial size 12ml l Pressure protection for wash l Position adjustment by AA Win software l Reproducibility Cu < 0.6% (air/acetylene) Cu< 1.0% (air/LPG)...
Open the catalog to page 15All PG INSTRUMENTS LIMITED catalogs and technical brochures
-
CCD METAL ANALYSER
9 Pages
-
UV-Win6
102 Pages
-
GC650
12 Pages
-
Tintration System
4 Pages
-
FP902
4 Pages
-
pH-Conductivity Meter
2 Pages
-
UV-WinGLP
4 Pages
-
T110+/T112+
2 Pages
-
T92+
4 Pages
-
T85
4 Pages
-
T80
4 Pages
-
T70
4 Pages
-
T75
4 Pages
-
T60
4 Pages
-
C30/C30M
4 Pages
-
Micron-Mist
2 Pages
-
AA990F
2 Pages
-
FP910
4 Pages
-
AF420
4 Pages
-
PG990
2 Pages
-
AA500
4 Pages
-
ICP 5000
4 Pages
-
AA500 IQ/OQ Kit
2 Pages
-
Atomic Fluorescence
2 Pages
-
Adjustable Nebuliser for AAS
1 Pages
-
UV IQ/OQ
2 Pages
-
FLAME PHOTOMETER
4 Pages
Archived catalogs
-
Gas Chromatograph
2 Pages
-
Flame Photometer
2 Pages
-
Atomic Absorption
4 Pages
-
Spectrophotometer
44 Pages