Various Application 5 kinds of sample injectors and all conventional detectors can be attachable depending on samples for analysis. In particular, for analysis of environmental samples (water quality, air, soil and wastes) satisfactory outcome can be achieved by connect
Open the catalog to page 1● Automatic flow control and ignition of the FID- ● Full automatic flow control of IPC flame ● Auto-start of chromatogram when sample is injected ● Gas save function (Capillary Injector) ● Pressure range: 0-100psi (resolution: 0.01psi) ● Flow range: 0-500mL/min (resolution: 0.01mL/min) ● Split ratio up to 5000:1 ● TCD maximum current control based on the type of gas ● Optional valves (solenoid, 2-position) control function ● Automatic notification of power-off Inlet System : Excellent accuracy, reproducibility Packed Inlet ● 1/4”,1/8” Glass-lined Metal Liner are available ● On-Column...
Open the catalog to page 2● Dual inlet injection capability ● Two Valves can be controlled by Air Actuation ● Variable injection/syringe fill rates ● Full automation system is built along with the automatic Run/Stop function ● Multiple solvent/waste bottles ● Syringe range 5uL-250uL ● Air gapping capability ● Multiple tray options: 120 vials, 1.8mL; 220 vials, 0.8mL; 60 vials, 10mL Detectors : High selectivity and sensitivity FID (Flame lonization Detector) ● Improved sensitivity into 19mCoulomb/g Carbon ● Easy to disassemble and assemble detector ● Minimization of sample degeneration as well as jet pollution by...
Open the catalog to page 3TID (Thermionic Ionization Detector); NPD ● Selective reaction to phosphorous or nitrogen compounds like organic phosphorous pesticides ● TID Bead Current Auto Optimization: Automatic ignition as the optimal current supplied by sensing the bead condition of alkali Rb Salt. ● The induction of nitrogen/phosphorous is more 104 times than that of carbon PDD (Pulsed Discharge Detector) ● ECD Mode: Analysis of organic chloric pesticide
Open the catalog to page 4● Exact flow/pressure control by IPC (Intelligent ● Checking Analysis Progress Pneumatic Control) ● Auto ignition of FID flame ● Confirming Serial Number and Hardware Version ● Confirming Error Message ● Auto control of TCD current ● Auto start function as sample injection (Better reproducibility) ● Check for GC operation by STATUS INFORMATION window ● Auto repeat analysis function ● Can Control 2-Position Valves (2ea) and Solenoid Valves (6ea) ● Gas save function Safety Function ● In case of FID flame off, auto off for Air/H2/ Make-up gas flow (available from next version) ● TCD Filament...
Open the catalog to page 5Schedule Program ● Control Solenoid Valves and 2-Position Valves ● Auto Repeat Analysis Corbra Liquid Auto Sampler Features ● Direct Syringe Injection ● Variable Injection Rates ● Variable Syringe Fill Rates ● Dual Inlet Injection Capability ● Syringe Range 5uL-250uL ● Multiple Tray Option: 120 vials, 1.8mL; 220 vials, 0.8mL; 60 vials, 10mL ● Uses Off-the Shelf Syringes EST Cobra Auto Sampler The Cobra liquid auto sampler, an entirely new sampling system designed and built to automate any GC. If you are looking for a sampling system to replace an older, less reliable auto sampler, the Cobra...
Open the catalog to page 6Headspace Auto Sampler Productivity ● Horizontal rotary evaporation cuts equilibration times by 80% ● High-capacity 90-position sample carousel ● Automatic leak and integrity check Patented Dual Needle Dynamic Headspace The HS9000 utilizes a closed sample introduction ● Static Loop Injection-A fixed volume loop system. Unlike syringe injection systems, the loss available in various sizes is filled with the headspace of headspace vapor during the injection process vapor to inject a known volume of sample into the due to vapor pressure changes is never a concern. In addition to the...
Open the catalog to page 7GC650 Specifications Column Oven
Open the catalog to page 8Inlet Modules Pressure sensor
Open the catalog to page 9Inlet System (Injector) Maximum installed Qty. Packed column inlet, Septum purge Packed column Inlet, Capillary Column Inlet, GSV, Auto Gas Sampling System and etc. Temp. Range Ambient to 400℃ 1/4", 1/8" Glass-lined Metal Liner are available. Packed Inlet On-Column injection method is available using 1/4" Glass Column 0.53mm ID Capillary Column can be used Capillary Inlet High resolution, prompt analysis time and most typical inlet system Split and Splitless mode can be selectable 4 Valves can be controlled by Air Actuation Controlling Multi Position Valve Full automation system is built...
Open the catalog to page 10All PG INSTRUMENTS LIMITED catalogs and technical brochures
-
CCD METAL ANALYSER
9 Pages
-
UV-Win6
102 Pages
-
Tintration System
4 Pages
-
FP902
4 Pages
-
pH-Conductivity Meter
2 Pages
-
UV-WinGLP
4 Pages
-
T110+/T112+
2 Pages
-
T92+
4 Pages
-
T85
4 Pages
-
T80
4 Pages
-
T70
4 Pages
-
T75
4 Pages
-
T60
4 Pages
-
C30/C30M
4 Pages
-
Micron-Mist
2 Pages
-
AA990F
2 Pages
-
FP910
4 Pages
-
AF420
4 Pages
-
PG990
2 Pages
-
AA500
4 Pages
-
ICP 5000
4 Pages
-
AA500 IQ/OQ Kit
2 Pages
-
Atomic Fluorescence
2 Pages
-
Adjustable Nebuliser for AAS
1 Pages
-
Spectroscopy Brochure
43 Pages
-
UV IQ/OQ
2 Pages
-
FLAME PHOTOMETER
4 Pages
Archived catalogs
-
Gas Chromatograph
2 Pages
-
Flame Photometer
2 Pages
-
Atomic Absorption
4 Pages
-
Spectrophotometer
44 Pages