Overview: The AA500 Atomic Absorption Spectrometer is a high-performance, automated instrument designed for diverse laboratory applications, including agricultural, clinical, environmental, food, metal, mining, geological, petrochemical, and pharmaceutical sectors. It is available in three configurations: AA500F (Flame Atomiser), AA500G (Graphite Furnace Atomiser), and AA500FG (both Flame and Graphite Atomisers).
Configurations:
  • AA500F: Equipped with a flame atomiser, offering three flame options: Air/Acetylene (standard), N2O/Acetylene, and Air/LPG. It features a coded burner for safety and is controlled by embedded software.
  • AA500G: Features a graphite furnace atomiser with a fixed graphite head for optimal performance. It includes a precision feedback system for temperature control and pyrolytically coated platform tubes.
  • AA500FG: Combines both flame and graphite atomisers, allowing easy switching between modes via software.
Features & Functions:
  • Embedded PC system with pre-installed AAWin3 software for full instrument control.
  • Automatic 8 Hollow Cathode lamp turret with individual control to eliminate drift.
  • D2 lamp and Self Reversal background correction systems for versatile element analysis.
  • High precision optics and Czerny-Turner monochromator for maximum light throughput.
  • Optional universal and XYZ autosamplers for high sample volume and throughput.
Flame Atomiser Features:
  • Air/Acetylene flame with high sensitivity and computer-controlled settings.
  • N2O/Acetylene flame for elements less prone to ionization.
  • Air/Propane (LPG) flame for alkali metals, offering a safer alternative in remote areas.
  • Safety features include pressure monitoring, flame sensor, and gas leak detector.
Graphite Atomiser Features:
  • Fixed graphite furnace head for simple alignment and motorised positioning.
  • Precision feedback system for temperature control and pyrolytically coated tubes.
  • Up to 10 programmable heat stages and efficient cooling system.
  • Safety features include argon gas pressure sensor and over-temperature sensor.
Specifications:
  • Wavelength Range: 185nm-910nm
  • Monochromator: Czerny-Turner Configuration
  • Spectral Bandwidth: 0.1nm to 2.0nm (software selectable)
  • Wavelength Accuracy: ± 0.15nm
  • Detection Limit: Cu < 0.004 µg/ml (flame), Cd < 0.4 x 10-12g (graphite furnace)
  • Safety Functions: Include burner identification, flame sensor, and gas leak sensor.
Contact Information: PG Instruments Ltd, Alma Park, Wibtoft, Leicestershire, LE17 5BH, England. Tel: 0044 (0) 1455 220131, Fax: 0044 (0) 1455 220025, Email: [email protected]
See more

Catalog excerpts

AA500-1

The AA500 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications including: • Agricultural • Clinical • Environmental • Food • Metal • Mining • Geological • Petrochemical • Pharmaceutical The versatile instrument is available in three configurations: AA500F - The instrument is equipped with a flame atomiser only. The positioning of which is fully controlled by the embedded computer system and AA Win software. Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (Natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection.

 Open the catalog to page 1
AA500-2

instrumentsAnalytical Instruments for Science AA500G - The instrument is equipped with a Graphite Furnace Atomiser only. The graphite head is fixed into the optical path to maximise performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. AA500FG - The instrument is equipped with both Flame Atomiser and Graphite Atomiser as described above....

 Open the catalog to page 2
AA500-3

• This flame uses a 3 slot burner and with the low pressure requirement it is also much safer to operate. • Due to the low temperature of the flame it is ideal for analysing alkali metals such as: Potassium, Sodium and Lithium, especially when used in the emission mode. • Some remote areas of the world have difficulty obtaining Acetylene gas of a high enough purity to operate the flame correctly, LPG can give a real alternative and offer comparable results for most elements throughout the wavelength range. • Pressure monitoring for all gases • Burner Identification • Flame sensor • Drain Trap...

 Open the catalog to page 3
AA500-4

instrumentsAnalytical Instruments for Science Wavelength Range 185nm-910nm Monochromator Czerny-Turner Configuration (Double Beam Option Available) Wavelength Accuracy ± 0.15nm Wavelength Reproducibility < 0.05nm Sensitivity (Cu) 2 pg/ml Absorption > 0.28A (flame) Detection Limit Cu < 0.004 pg/ml (flame) Cd < 0.4 x 10-12g (graphite furnace) Repeatability Cu < 0.7% (Air/Acetylene flame) Ba < 1.0% (Nitrous oxide/Acetylene flame) Cu < 2.0% Cd < 2.0% (Graphite Furnace) Background Correction Deuterium Arc, Self reversal Characteristic Concentration Cu < 0.02 pg/ml,...

 Open the catalog to page 4

All PG INSTRUMENTS LIMITED catalogs and technical brochures

  1. UV-Win6

    102  Pages

  2. GC650

    12  Pages

  3. FP902

    4  Pages

  4. UV-WinGLP

    4  Pages

  5. T110+/T112+

    2  Pages

  6. T92+

    4  Pages

  7. T85

    4  Pages

  8. T80

    4  Pages

  9. T70

    4  Pages

  10. T75

    4  Pages

  11. T60

    4  Pages

  12. C30/C30M

    4  Pages

  13. Micron-Mist

    2  Pages

  14. AA990F

    2  Pages

  15. FP910

    4  Pages

  16. AF420

    4  Pages

  17. PG990

    2  Pages

  18. ICP 5000

    4  Pages

  19. UV IQ/OQ

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.