Roots Pumps
32Pages

{{requestButtons}}

Catalog excerpts

Roots Pumps - 1

ROOTS PUMPS For all low and medium vacuum applications

Open the catalog to page 1
Roots Pumps - 3

Introduction Roots pumps. . . . . . . . . . . . . . . . . . . . . . . . . 4 Overview / Applications Convection-cooled – OktaLine . . . . . . . . . . . . . . . . . . . . . Function and description. . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pumping speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical data / Order numbers / Accessories . . . . . . . . . Gas-circulation-cooled – OktaLine G. . . . . . . . . . . . . . . . . Function and description. . . . . . . . . . . . . . . ....

Open the catalog to page 3
Roots Pumps - 5

For all low and medium vacuum applications The OktaLine series Roots pumps can be perfectly tailored to customer-specific requirements by different pumping speeds and versions. This type of pump needs a backing pump both suited to the application and designed for the gas stream. The high-precision production technology makes it possible to achieve very high compression values, which in turn allows for maximum pumping speed at very low gas exit temperatures. Pfeiffer Vacuum Roots pumps offer low operating costs at high uptime, since electrical power and (depending on the process) a gaseous...

Open the catalog to page 5
Roots Pumps - 6

Gas-circulation-cooled - OktaLine G Okta 500 G Okta 1500 G Okta 4000 G Okta 8000 G Explosion-protected -Okta 500 ATEX Okta 1000 ATEX Okta 2000 ATEX Okta 4000 ATEX OktaLine ATEX

Open the catalog to page 6
Roots Pumps - 7

Convection-cooled – OktaLine Gas-circulation-cooled – OktaLine G Explosion-protected – OktaLine ATEX (in accordance with Directive 94/9/EC) Magnetic coupling as an option of all models The integrated overflow valve is standard in all convectioncooled pumps. This makes it possible to switch the pump on at atmospheric pressure. The pump is thus automatically protected from thermal overload. The gain in additional pumping speed allow for shorter cycle times in load lock applications and time-critical processes. Monitoring with fault-prone pressure switches and slow start up with cost-intensive...

Open the catalog to page 7
Roots Pumps - 8

Convection-cooled OktaLine Roots pumps for all low and medium vacuum applications Customer benefits The pumping speeds of convection-cooled Roots pumps range from 145 to 27,400 m3/ h . They can easily be combined and used in low and medium vacuum applications . Typical uses include industrial applications, coating, the semiconductor industry and research and development, or in chemical and process technology applications . The gear box and bearings in our Roots pumps are separated from the gas pumping chamber. The contactless operating principle of the Roots pistons allows for technically...

Open the catalog to page 8
Roots Pumps - 9

Applications    ■ Metallurgy Simulation chambers Packaging industry Freeze/vacuum-drying Thin-film technology Electron beam welding Load-locks Chemistry and process technology Industrial leak detection systems Steel degassing

Open the catalog to page 9
Roots Pumps - 10

standard    without motor DN 1 DN 63 ISO-F DN 63 ISO-F DN 63 ISO-F DN 2 DN 63 ISO-F DN 63 ISO-F DN 63 ISO-F standard    without motor DN 1 DN 100 ISO-F    DN 100 ISO-F    DN 100 ISO-F DN 2 DN 100 ISO-F    DN 100 ISO-F    DN 100 ISO-F

Open the catalog to page 10
Roots Pumps - 11

standard    without motor 1000 M standard    without motor 2000 M standard    without motor 4000 M

Open the catalog to page 11
Roots Pumps - 12

standard    without motor 6000 M Okta 8000 Okta 8000 standard without motor

Open the catalog to page 12
Roots Pumps - 13

Pumping speed Okta 250 Okta 250, rotation speed 3000 min-1 Okta 500, rotation speed 3000 min-1 Okta 1000, rotation speed 3000 min-1 Okta 6000, rotation speed 3000 min-1 Okta 8000, rotation speed 1500 min-1 Okta 4000, rotation speed 3000 min-1 Okta 2000, rotation speed 3000 min-1 Okta 18000, rotation speed 1500 min-1

Open the catalog to page 13
Roots Pumps - 14

Technical data DN 63 ISO-F    DN 100 ISO-F DN 63 ISO-F    DN 100 ISO-F Operating fluid11 Operating fluid filling Differential pressure at the overflow valve21 Rotation speed max. Rotation speed min . Emission sound pressure level (EN ISO 2151) at intake pressure10 hPa Emission sound pressure level (EN ISO 2151) at intake pressure1 hPa Weight: with motor Weight: without motor Weight: with magnet coupling Cooling method, standard Leak rate: standard Leak rate: with magnet coupling Motor protection Nominal rotation speed at 50 Hz Nominal rotation speed at 60 Hz Rated power 50 Hz Rated power 60...

Open the catalog to page 14
Roots Pumps - 16

High differential pressures with lower power consumption High pressure ranges and maximum differential pressures, in continuous operation up to 870 hPa, are ideal operating conditions for gas-circulation-cooled Roots pumps in the OktaLine G series. At various power ratings from 5.5 kW up to a nominal rating of 200 kW, a pumping speed of 210 to 12,000 m3/h can be achieved. Gas-circulation-cooled Roots pumps can be operated without backing pumps. Thanks to the frequency converter, energy use can be significantly reduced. Pumping speeds can be precisely adjusted. Gascirculation-cooled Roots...

Open the catalog to page 16
Roots Pumps - 17

Applications    ■ Electron beam welding Vacuum furnaces Plasma research Particle accelerators Space simulation Chemical and process technology

Open the catalog to page 17
Roots Pumps - 21

100 Okta 4000 G, rotation speed 1500 min-1 100 Okta 8000 G, rotation speed 1500 min-1

Open the catalog to page 21
Roots Pumps - 22

Technical data Flange (out) Flange (in) Operating fluid11 Operating fluid filling Rotation speed Rotation speed max. Rotation speed min . Ultimate pressure without gas ballast Weight: without motor Cooling method, standard Cooling gas connection Leak rate Motor rating Nominal rotation speed at 50 Hz Nominal rotation speed at 60 Hz Nominal pumping speed Nominal pumping speed at 50 Hz Nominal pumping speed at 60 Hz Noise level with connected exhaust line Protection category Sealing gas Ambient temperature Splinter shield fur Okta G    PP 030 149 AX    PP 031 114 -X 11 Additional equipment and...

Open the catalog to page 22

All Pfeiffer Vacuum catalogs and technical brochures

  1. Turbopumps