Group: Busch Group
Catalog excerpts
Vacuum distillation OktaLine® ATEX Explosion-proof Roots pumps Vacuum furnaces
Open the catalog to page 1OktaLine® ATEX Explosion-proof Roots pumps Hermetically sealed for maximum operational safety Your added value Explosion-proof due to pressure surge resistance to PN 16 ATEX approval for use in rough and fine vacuum OktaLine Roots pumps are the right choice for processes in potentially explosive atmospheres or for evacuating explosive gases. Thanks to conformity to ATEX Directive 2014/34/EU1) and pressure surge resistance to PN16, they meet the highest requirements for explosion protection. Hermetically sealed for maximum operational reliability Thanks to their magnetic coupling with...
Open the catalog to page 2Higher performance with a pumping speed up to 8,100m³/h Can be used individually for ambient temperatures from -20 to +40 °C °C Protection against thermal overload thanks to integrated temperature sensor Easy installation and maintenance Technically dry operation The gear and bearing housings are separated from the pumping chamber by labyrinth seals. Contact-free rotation of the Roots ensures technically dry operation. Flexible in application Thanks to the variable differential pressure and flexible rotation speed, the pumps can be used universally. All pumps can be used in ambient...
Open the catalog to page 3OktaLine® ATEX ATEX regulations Certification for ATEX The word ATEX is an acronym from French and stands for ATmosphères EXplosibles. Vacuum pumps for use in a potentially explosive atmosphere must be certified in accordance with 2014/34/EU. To do this, the measures shown in Figure 1 must be carried out. The first step is the analysis of potential ignition sources. Depending on the category in the CE marking, the status regular operation (category 3), expected failure (category 2) and rare failure (category 1) are considered with regard to potential ignition sources. The next step is to...
Open the catalog to page 41 Motor 2 Floating bearing 3 Suction connection 4 Roots 5 Labyrinth seal 6 Gearbox 7 Oil filler plug 8 Suction chamber 9 Oil level glass 10 Labyrinth seal 11 Pressure connection 10 4 11 5 6 Figure 2: Schematic design of a Roots vacuum pump (3) to the pressure port (11). A motor (1) drives the main lobe. The pair of gears (6) in the gear chamber synchronizes two rotors piston. Lubricants are used exclusively in the gear and bearing housings. These are separated from the suction chamber (8) by a labyrinth seal (5). Narrow gaps between the piston and housing ensure contact-free running. This...
Open the catalog to page 5OktaLine® ATEX Dimensional drawings Okta 500 ATEX 250 15 Sealing groove Inner Ø126 Outer Ø138 Depth 3.4 mm M16 -20/22 deep (8x) Ø1 ATEX temperature sensor Sealing groove Inner Ø162 Outer Ø174 Depth 3,4 mm ATEX temperature sensor
Open the catalog to page 6Sealing groove Inner Ø162 Outer Ø174 Depth 3,4 mm ATEX temperature sensor vacuum flange
Open the catalog to page 7OktaLine® ATEX Pumping speed Okta 500 ATEX (60 Hz) Okta 500 ATEX (50 Hz) Okta 500 ATEX (25 Hz) 3 Backing pump 120 m³/h/h Backing pump 120 m Okta 1000 ATEX (60 Hz) Okta 1000 ATEX (50 Hz) Okta 1000 ATEX (25 Hz) Backing pump 300 m³/h/h Backing pump 300 m3 10 0.001
Open the catalog to page 8Okta 2000 ATEX (60 Hz) Okta 2000 ATEX (50 Hz) Okta 2000 ATEX (25 Hz) Backing pump 630 m³/h/h Backing pump 630 m3 100 0.01 Okta 8100 ATEX (75 Hz) Okta 8100 ATEX (60 Hz) Okta 5400 ATEX (50 Hz) Okta 5400 ATEX (38 Hz) Okta 5400 ATEX (25 Hz) Backing pump Backing pump 100 0.01
Open the catalog to page 9OktaLine® ATEX Technical data Technical data Version Equipment category Nominal pumping speed Pumping speed range Pumping speed at 60 Hz Rated speed Speed min. Max. speed Connection flange (inlet) Connection flange (output) Weight: with motor Leak rate Ambient temperature Cooling type, standard Operating medium1) Operating medium quantity Emission sound pressure level (EN ISO 2151) at intake pressure 10 hPa Emission sound pressure level (EN ISO 2151) at intake pressure 1 hPa Nominal power 50 Hz Rated power 60 Hz Mains connection: Voltage 50 Hz Mains connection: Voltage 60 Hz Motor...
Open the catalog to page 108, 100 m3/h Nominal pumping speed
Open the catalog to page 11Errors excepted. All data subject to change without prior notice. PW 0042 PEN (May 2022/PoD) We give our best for you every day – worldwide! Are you looking for an optimal vacuum solution? Please contact us: Pfeiffer Vacuum GmbH Germany Phone +49 6441 802-0
Open the catalog to page 12All Pfeiffer Vacuum+Fab Solutions catalogs and technical brochures
-
HiQuad Neo
8 Pages
-
DuoVane 22
4 Pages
-
Product overview
56 Pages
-
HiCube Neo
8 Pages
-
SpeedAir
8 Pages
-
HiPace 80 Neo
12 Pages
-
Duo 1.6/M
16 Pages
-
SmartVane
8 Pages
-
Turbo Pumping Stations - HiCube
20 Pages
-
Pascal 2021 HW
4 Pages
-
Roots Pumps
32 Pages
-
Vacuum for life
32 Pages
-
Rotary vane pumps - DuoLine
16 Pages
-
ActiveLine Gauges
8 Pages
-
Transmitters - ActiveLine
8 Pages
-
Duo 3 DC - Rotary vane pumps
4 Pages
-
HiPace 30 - Turbopumps
4 Pages
-
Leak Detection Compendium
74 Pages
-
Chambers and Components (Part 3.3)
399 Pages
-
Vacuum generation (Part 3.1)
475 Pages
-
Know-how book (Part 2)
140 Pages
Archived catalogs
-
AMI 1000
8 Pages