New Filterfans - 4th Generation Neue Filterlüfter - 4. Generation The extra servicefriendly Filterfan Der besonders servicefreundliche Filterlüfter Filterfans / Filterlüfter · Edition 11.1

 Open the catalog to page 1
New Filterfans - 4th Generation-2

A Passion for Innovation Innovationen sind Dear business partners, Sehr geehrte Geschäftspartner, with the invention of the Filterfan by Otto Pfannenberg in 1958, the company Pfannenberg had set a milestone in industrial climatisation. In cooperation with switchgear cabinet and machinery manufacturers operating in different market segments, we have created the 4th Generation of the Pfannenberg Filterfan and thus made an important step towards a new world standard. This newly developed Filterfan is even more servicefriendly due to its modular structure. The air-ow optimised design with its patented...

 Open the catalog to page 2
New Filterfans - 4th Generation-3

n ... unsere Leidenschaft ... 5 sizes, 8 performance classes IP 54 and 7 performance classes IP 55 5 Baugrößen, 8 Leistungsklassen IP 54 und 7 Leistungsklassen IP 55 THE innovation on the Filterfan market With the innovative 4th Generation of Filterfans, Pfannenberg offers you real competitive advantages. The development of the new generation includes of course all national and international norms and standards e.g. TÜV, NEMA, UL and GOST. In addition, there are the classical attributes of the Pfannenberg Filterfans such as at modern industrial design and easy assembly without the need for tools...

 Open the catalog to page 3
New Filterfans - 4th Generation-4

The extra servicefriendly Filterfan! Der besonders servicefreundliche Filterlüfter! Bound to lead by inventing modern innovative products! This is Pfannenberg’s mission! Pfannenberg gestaltet Vorsprung – mit modernen innovativen Produkten. No tools required for assembly! The assembly does not require tools – mounting of the IP 54 lterfans is completed! IP 55 Werkzeuglos! Werkzeuglose Montage – schraubenlose Befestigung. Für den Einbau des Filterlüfters ist kein Werkzeug erforderlich! 4-corner fastening system ”click and t!” This extremely safe mounting system is patented! 4-Ecken-Verrastung!...

 Open the catalog to page 4
New Filterfans - 4th Generation-5

Electrical power consumption at same airow rate in % Elektrische Leistungsaufnahme bei gleicher Luftfördermenge in % 100% 90% 80% 70% 60% 50% Pfannenberg Filterfans 4th Generation / Pfannenberg Filterlüfter 4. Generation Pfannenberg Filterfans 3rd Generation / Pfannenberg Filterlüfter 3. Generation Installation sizes / Baureihen An easier connection to power by clamps it cannot be easier! Leichter Elektroanschluss durch Klemmen Schneller und leichter geht es nicht mehr! Fitting is compatible! Change to new 4th Generation Filterfan easily as all the cutouts are compatible with the previous generation!...

 Open the catalog to page 5
New Filterfans - 4th Generation-6

Filterfans / Filterlüfter Filterfan / Filterlüfter PF 11.000 Exhaust lter / Austrittslter PFA 10.000 For versatile incorporation into equipment. Examples are in the medical industry, in EDP/IT equipment, warning and control enclosures and also for low power applications. Vielseitige Einsatzmöglichkeiten im Apparatebau, in der Medizintechnik, in EDV/IT-Anlagen, Melde- und Befehlsgehäusen, sowie für den Kleinleistungsbereich. Data / Daten Article number / Artikelnummer Unit / Einheit AC 50 Hz / 60 Hz Rated voltage / Nennspannung ± 10% Unimpeded airow / Luftfördermenge freiblasend Power consumption...

 Open the catalog to page 6
New Filterfans - 4th Generation-7

Cooling capacity performance curves / Kennlinien Kühlleistung Temperature difference / Temperaturdifferenz ∆T [K] Statischer Druck [Pa] Kühlleistung [W] 70 300 for material thickness up to / für Materialdicke bis 2 mm +1 mm for thickness of material / für Materialdicke > 2 mm ≤ 3 mm 200 Airow rate / Luftfördermenge [m3/h] Filterfans / Filterlüfter Statischer Druck [Pa] Static pressure / Statischer Druck [Pa] Kühlleistung [W] Cooling capacity / Kühlleistung [W] Kennlinien Statischer Druck 0 0 10 15 20 25 30 35 40 Further technical 5 information can be found on the Internet: www.pfannenberg.com...

 Open the catalog to page 7
New Filterfans - 4th Generation-8

Filterfans / Filterlüfter Filterfan / Filterlüfter PF 22.000 Exhaust lter / Austrittslter PFA 20.000 For a broad range of applications in electronics as well as conventional switchgear installations; a wide range of operating voltages ensures universal use. Für viele Anwendungsbereiche im elektronischen sowie konventionellen Schaltanlagenbau. Universell einsetzbar durch die breite Spannungspalette. Data / Daten Article number / Artikelnummer Unit / Einheit AC 50 Hz / 60 Hz Rated voltage / Nennspannung ± 10% Unimpeded airow / Luftfördermenge freiblasend Power consumption / Leistungsaufnahme Current...

 Open the catalog to page 8
New Filterfans - 4th Generation-9

Luftfördermenge [m3/h] Statischer Druck [Pa] 38 PF 22.000 / PF / 20.000 IP54 PF 22.000 IP54 IP55A PFA 20.000 IP55 Static pressure performance curves / capacity performance curves / Kennlinien Kühlleistung Kühlleistung Statischer Druck PF 22.000 IP 54 [Pa] [W] Static pressure / Statischer Druck [Pa] Kennlinien Statischer Druck Cooling capacity / Kühlleistung [W] Airow rate / Luftfördermenge [m3/h] PFA Luftfördermenge [m3/h] PF + 800 1 50for material thickness up to / für Materialdicke bisPFmm PFA 2 +2 +1 mm for thickness of material / für Materialdicke > 2 mm ≤ 3 mm 700 40 600 PFA 30 500 Statischer...

 Open the catalog to page 9
New Filterfans - 4th Generation-10

Filterfans / Filterlüfter Filterfan / Filterlüfter PF 32.000 Exhaust lter / Austrittslter PFA 30.000 For a broad range of applications in electronics as well as conventional switchgear installations; a wide range of operating voltages ensures universal use. Für viele Anwendungsbereiche im elektronischen sowie konventionellen Schaltanlagenbau. Universell einsetzbar durch die breite Spannungspalette. Data / Daten Article number / Artikelnummer Unit / Einheit AC 50 Hz / 60 Hz Rated voltage / Nennspannung ± 10% Unimpeded airow / Luftfördermenge freiblasend Current consumption / Stromaufnahme Noise...

 Open the catalog to page 10
New Filterfans - 4th Generation-11

Luftfördermenge [m /h] Kühlleistung [W] 600 Statischer Druck [Pa] Statischer Druck [Pa] ELECTRO-TECHNOLOGY FOR INDUSTRY capacity performance curves / Kennlinien Kühlleistung Cooling capacity / Kühlleistung [W] Kühlleistung Statischer Druck PF 32.000 IP 54 [Pa] [W] 40 Static pressure / Statischer Druck [Pa] PF 32.000 IP55Luftfördermenge [m3IP55T [K] PF/A 30.000 /h] [m T Luftfördermenge Airow/ rate emperaturdifferenz 3/h] Static pressure / Statischer Druck [Pa] Cooling capacity / Kühlleistung [W] PF 32.000 / PFA PFA Temperaturdifferenz ∆T [K] PF 32.000 IP54IP55difference /30.000 T [K] T / 30.000...