PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: [email protected] Web: www.petrosystem.it Clamp On Ultrasonic Flowmeter 7000 Series ? Dual mode flowmeter mounted in IP 65 field enclosure ? Easy to install clamp-on sensors with no process interruption ? Non-invasive flow measurement of liquids , no pipeline disturbance, no pressure loss ? Suitable for all commonly used pipe materials with pipe diameters from 10 mm to 6.5 m (1/4" to 256" ) ? 1 or 2 flow channels Description: Our range of non-invasive flowmeters utilises ultrasonic technology for the accurate flow measurement of liquids in full pipes. The field mounted flow transmitter can be configured via keypad without any additional programming devices and is available as single or dual channel unit. The measurement of flow is based on the principle that sound waves are influenced by a flowing medium. Measurements are made by penetrating the pipe with ultrasound and subsequently time differences, frequency variations and phase shifts of the ultrasonic signals are evaluated. This measuring technique has no effect on the flowing liquid. There is no pressure loss in the pipe and no wear on components of the measuring device. The ultrasonic sensors are clamped onto the outside of the pipe, thus eliminating the need to dismantle the pipework and interrupt the process. The 7000 Series can be applied to any type of standard pipe carrying clean or dirty liquids. Advantages ? Low installation effort and costs ? Measurement is independent of fluid conductivity and pressure ? No pressure loss , no possibility of leakage ? Retrospective installation for existing plants possible ? No cutting of pipes neces sary, no interruption of process , no plant shut down ? No additional fittings for maintenance required ? Hygienic measurement, no risk of contamination, suitable for ultra clean liquids ? No contact with medium, no risk of corrosion when used with aggressive media ? Cost advantages when used with large diameter pipes, high pressure systems, etc. ? Low stock costs, nearly all pipe sizes are covered with only 2 types of sensors Specification General Measuring principle Flow velocity range Resolution Repeatibility Accuracy Turn down ratio Gaseous and solid content of medium Flow transmitter Enclosure Degree of protection Operating temperature Housing material Flow channels Power supply Display Dimensions Weight Power consumption Signal damping Ultrasonic time difference correlation principle 0.01 ... 25 m/s 0.025 cm/s 0.15 % of measured value ± 0.015 m/s Volume flow: ± 1 .. 3 % of measured value depending on application, ± 0.5 % of measured value with process calibration Flow velocity: ± 0.5 % of measured value 1/200 Wall mounted housing IP 65 according E N 60529 10 ... 60 °C (14 ... 140 °F ) : Aluminium, powder coated 1 or 2 100 . 240 V AC / 9 .18 V DC / 18 . 36 V DC / 36 . 72 V DC 2 x 16 digit LCD, dot matrix, backlit H 200 x W 280 x D 70 mm Approx. 2.8 kg < 15 W 0 ... 60 s
Open the catalog to page 1PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: [email protected] Web: www.petrosystem.it Specifications Flow transmitter (cont.) Clamp-on sensors Response time 1 s Type M2N, M2E Measuring cycle 100 ... 1000 Hz, single channel Rated (possible) Calculation functions Average/difference/sum diameter range (50) 100 ... 6500 mm Operating languages Selectable between Danish, Dimensions 60 x 30 x 34 mm English, German, French, Material Stainless steel Dutch, Norwegian, Polish, Temperature range Type M2N: Czech, Turkish, Spanish...
Open the catalog to page 2PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: [email protected] Web: www.petrosystem.it External Dimensions
Open the catalog to page 3PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: [email protected] Web: www.petrosystem.it Clamp On Ultrasonic Flowmeter 8000 Series ? Dual mode field Transmitter ? Easy to install clamp-on sensors with no process interruption ? Non-invasive flow measurement of liquids , no pipeline disturbance, no pressure loss ? Suitable for all commonly used pipe materials with pipe diameters from 10 mm to 6.5 m (1/4" to 256" ) ? 2 flow channels standard, IP 66 housing ? Certified for hazardous areas Zone 1 & 2 Description: Our range...
Open the catalog to page 4PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: [email protected] Web: www.petrosystem.it Flow transmitter (cont.) Clamp-on sensors Enclosure Field transmitter housing Type Q4N-Ex, M4N-Ex Degree of protection IP 66 according EN 60529 (for use in hazardous areas Zone 1 and 2) Operating temperature -10 ... 55 °C (14 ... 131 °F) Rated (possible) Housing material Aluminium, powder coated diameter range Type Q4N-Ex Flow channels 2 (10) 25 ... 400 (1000) mm Power supply 100 ... 240 V AC / 9 ...18 V DC / Type M4N-Ex 18 ......
Open the catalog to page 5PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: [email protected] Web: www.petrosystem.it External Dimensions
Open the catalog to page 63 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
2 Pages
3 Pages
1 Page
1 Page
4 Pages
3 Pages
3 Pages
1 Page
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
4 Pages
11 Pages
2 Pages
2 Pages
7 Pages
2 Pages
6 Pages
1 Page
2 Pages
1 Page
4 Pages
3 Pages
8 Pages
1 Page
3 Pages
1 Page
12 Pages
4 Pages
2 Pages
3 Pages
1 Page
4 Pages
1 Page
4 Pages
3 Pages
2 Pages
2 Pages
4 Pages
3 Pages
8 Pages
5 Pages
2 Pages
1 Page
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page