Non Intrusive Magnetic Pig Signallers - 1

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it web: www.petrosystem.it UNI-SIG NON-INTRUSIVE PIG SIGNALLER The Uni-Sig Non-Intrusive Pig Signaller makes pig detection incredibly easy. Easy to install and easy to read – the Remote indication System lets you see passage LEDs up to 100 meters away. The Uni-Sig Non-Intrusive Pig Signaller is completely nonintrusive and easily bands to the outside of pipelines from 2” to 60”. Since the Uni- Sig Non-Intrusive Pig Signaller is non-intrusive corrosion problems are avoided and installation can take place without hot-tapping or interrupting the flow of the system. Once installed the Uni-Sig Non-Intrusive Pig Signaller immediately begins scanning for both transmitter and permanent magnet equipped pig passages, and displays times and dates along with a “Recent Passage” message. A simple scroll through the Uni-Sig Non-Intrusive Pig Signaller memory reveals the last ten passages’ times and dates. The Uni-Sig Non-Intrusive Pig Signaller operates for a full year on just two standard D-cell alkaline batteries or can be connected to an existing 24VDC power. With the Uni-Sig Non-Intrusive Pig Signaller you can: ? Install it quickly and easily by simply banding it to pipelines from 6” to 60” with wall thicknesses of up to 1.5”. ? Detect both transmitter and permanent magnet equipped pipeline pigs. ? Install anywhere on a system without paying extra for explosion rated location due to the unit’s fully certified explosion-proof housing (with tempered glass window). ? Install either above or below ground. ? Retrieve the unit’s ten most recent pig passage times and dates ? Install just two D-cell alkaline batteries for a full year’s operation ? Utilize the suspend option which allows the system to be moved to different locations on your pipeline The Uni-Sig Non-Intrusive Pig Signaller detects pig passages with both permanent magnets and transmitters. Each method has distinctive advantages: Magnets: ? Small, powerful and inexpensive ? No batteries required

Open the catalog to page 1
Non Intrusive Magnetic Pig Signallers - 2

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it web: www.petrosystem.it Transmitters: ? Magnetic field emitted is readily detectable by the Uni-Sig Non-Intrusive Pig Signaller ? Stuck pigs can be found by starting at the last Uni-Sig Non-Intrusive Pig Signaller location it was known to have passed and walking the pipeline downstream using a location and tracking product The Uni-Sig Non-Intrusive Pig Signaller User Interface ? Simple and easy to read ? Able to quickly convey large amounts of...

Open the catalog to page 2
Non Intrusive Magnetic Pig Signallers - 3

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it web: www.petrosystem.it Electrical Specification: DESCRIPTION MIN TYP MAX UNIT OPERATING VOLTAGE (internal battery) 3 VDC OPERATING TEMPERATURE RANGE (standard detector) 20 20 85 °C DETECTION DISTANCE WITH 1000G MAGNET SOURCE 100 CM PIG SPEED DETECTION LIMITS 0 100 mtr/sec MOUNTING ORIENTATION AROUND PIPELINE 0 360 Degrees VOLT FREE OUTPUT CONTACT: 240 VAC OUTPUT SWITCHING CURRENT: 0.5 AMPS DETECTION TO OUTPUT RESPONSE TIME (rto) 0.1 0.5 0.8 ms AV...

Open the catalog to page 3
Non Intrusive Magnetic Pig Signallers - 4

PETROSYSTEM Srl Via Gaspare Spontini, 29/4 - 00043 Ciampino (Roma) – Italy Tel:+39 06 7932.1621 Fax:+39 06 7932.1160 Email: info@petrosystem.it web: www.petrosystem.it RELIABILITY The APD1 is probably the only pig detector currently available that is CE tested to the low voltage directive and is thus probably the only legal unit available on the market at a low price. Testing on a continuous cyclic hot-cold has clocked up in excess of 3000 continuous hours until the release of this data sheet and will continue to be tested until failure occurs we could have a long wait! EXTENDED TEMPERATURE...

Open the catalog to page 4

All PETROSYSTEM catalogs and technical brochures

  1. JIB CRANE

    1 Pages

  2. NYLON PLUG

    2 Pages

  3. Air Bags

    2 Pages

  4. FOAM PIGS

    2 Pages

  5. PIGS

    4 Pages

  6. OMNI PIG

    2 Pages

Archived catalogs

  1. DENDi SERIES

    1 Pages

  2. DC-40 SERIES

    1 Pages

  3. FOAM PIGS PE

    2 Pages

  4. CB-6

    8 Pages