ManualHalfbridge Transducer
19Pages

{{requestButtons}}

Catalog excerpts

ManualHalfbridge Transducer - 1

PETER HIRT GmbH Bedienungsanleitung Halbbrucken Messtaster Manual Halfbridge Transducer Serie T070, T100, T300 und T500 Series T070, T100, T300 and T500

Open the catalog to page 1
ManualHalfbridge Transducer - 2

Seite 2/19 Bedienungsanleitung Halbbrucken Messtaster

Open the catalog to page 2
ManualHalfbridge Transducer - 3

Anderungen und Irrtumer vorbehalten Seite 3/19

Open the catalog to page 3
ManualHalfbridge Transducer - 4

Haibbrucken Messtaster basieren auf dem Messprinzip eines Tauchankersystems. Die Messtaster zeichnen sich aus durch eine absolute Positionsmessung sowie durch hohe mechanische Robustheit. Diese Bedienungsanieitung deckt nachfoigend geiistete Produkte ab. Fur kundenspe-zifische Modeiie konnen Teiie dieser Bedienungsanieitung nichtig sein. Das entspre-chende Datenbiatt weist die abweichende Bedienung aus. Seite 4/19 Bedienungsanieitung Haibbrucken Messtaster

Open the catalog to page 4
ManualHalfbridge Transducer - 5

Anderungen und Irrtumer vorbehalten Seite 5/19

Open the catalog to page 5
ManualHalfbridge Transducer - 6

Seite 6/19 Bedienungsanleitung Halbbrucken Messtaster

Open the catalog to page 6
ManualHalfbridge Transducer - 7

Austausch des Messeinsatzes M2.5 Der Messeinsatz muss fur den Betrieb fest angezogen sein. Der Wechsel sowie das Festziehen des Messeinsatzes sind wie folgt durchzufuhren • Faltenbalg (3) mit kleinem Faltenbalgring (2) auf der Welle zuruckschieben bis die Schlusselflache zuganglich wird • Den mitgelieferten Schlussel in die Schlusselflache der Welle einfahren. Niemals am Gehause (6) halten (Messtaster wurde damit beschadigt) • Mit einer geeigneten Zange den Messeinsatz losen • Messeinsatz wechseln • Mit einer geeigneten Zange den Messeinsatz festziehen • Faltenbalg (3) mit kleinem...

Open the catalog to page 7
ManualHalfbridge Transducer - 8

Wechsel der Feder zur Änderung der Messkraft Zur Änderung der Messkraft kann die Feder gewechselt werden, bedingt jedoch eine Wiedereinstellung des Vorhubes sowie eine erneute Messmittelfähigkeitsprüfung. Der Hersteller empfiehlt diese Option bereits bei der Bestellung anzugeben. Ist ein Wechsel nach Auslieferung nötig, sollte dies bei einem autorisierten Händler geschehen. Befestigung des Messtasters Der Messtaster kann in der ganzen Länge des Gehäuses gespannt werden. Dabei ist zu beachten, dass nur so stark gespannt wird, dass die Kugelführung noch einwandfrei läuft. Ebenso ist das...

Open the catalog to page 8
ManualHalfbridge Transducer - 9

HIRT Halbbrucken Messtaster sind den lander- und regionenspezifischen Normen und Richtlinen konform. Nachfolgend ist dies aufgefuhrt. Richtlinie 2014/30/EU (CE-Kennzeichnung EMV-Richtlinie) Richtlinie 2011/65/EU (RoHS Richtlinie) HIRT Messtaster enthalten keine Stoffe welche die gemass Richtlinie 2011/65/EU festgelegten Hochstgrenzen an zulassigen Substanzen uberschreiten. Konfliktmineralien (Dodd Frank Act) Die im Messeinsatz verbaute Hartmetall-Kugel enthalt Wolfram. Die genaue Herkunft sowie die komplette Supply-Chain kann beim Hersteller erfragt werden. Anderungen und Irrtumer vorbehalten

Open the catalog to page 9
ManualHalfbridge Transducer - 10

Manual halfbridge Transducer Series T070, T100, T300 and T500 PRDK-0000007-DE-EN-000

Open the catalog to page 10
ManualHalfbridge Transducer - 11

Subject to change without notice. Errors and omission excepted

Open the catalog to page 11
ManualHalfbridge Transducer - 12

Halfbridge transducers base on the inductive core measurement principle. The probes are characterised by absolut position measurement and high mechanical robustness. This manual covers the underneath listed products. The handling of customer specific parts may deviate from the description in this manual. The corresponding datasheet inform about additional handling instructions. Manual halfbridge Transducer Series T070, T100, T300 and T500 PRDK-0000007-DE-EN-000

Open the catalog to page 12
ManualHalfbridge Transducer - 13

Subject to change without notice. Errors and omission excepted

Open the catalog to page 13
ManualHalfbridge Transducer - 14

Technical spcifications can be found on our webpage www.peterhirt.ch or in the main catalogue. Security advices Faulty transducers potentionally create wrong measurements. To prevent from this periodical plausibility checks must be foreseen. A well defined master piece to check the transducer's functionality shall be used. Periodical check To assure the transducer's functionality and its measuring ability, every year the device should be checked. Properties to be verified are • a well mechanical behaviour • metrology abilities as linearity, repeatability and measure value stability This...

Open the catalog to page 14
ManualHalfbridge Transducer - 15

M2.5 tip change When in application, the tip must be tightened. To change the tip the following steps shall be processed • Push back the bellow (3) by holding the front ring (2) with your fingers and moving this towards the body (6). You will see two areas on the shaft • Hold with the supplied special wrench the two flats on the shaft • Release the tip (1) with an appropriate plier • Change the tip (1) • Tight the new tip (1) with an appropriate plier • Bring back the bellow (3) to its initial position. Keep attention to not twist it, that all wrinkles are properly formed and that the small...

Open the catalog to page 15
ManualHalfbridge Transducer - 16

Fixing the transducer The transducer can be clamped on all shaft positions. Take attention to not overthight what could influence the linear bearing preload. The clamping elements must spread the force as good as possible to a wide area. Extension cable Extension cables influence the analog transducer signals and therefore induce small changes in the sensitivity and linearity error characteristics. For more details please contact the manufacturer directly. Application Sensitivity Setting HIRT halfbridge transducers are compatible with the TESA (R) standard. Electronics used to drive and...

Open the catalog to page 16
ManualHalfbridge Transducer - 17

Conformity HIRT transducers are conform to country and region specific guidelines and laws. Underneath the conformities are listed. Guideline 2014/30/EU (CE conformity EMC) Guideline 2011/65/EU (RoHS Guideline) HIRT transducers do not consist any materials which exceed the maximum allowed concentration as to 2011/65/EU Conflict minerals (Dodd Frank Act) The on the transducer mounted tip consists of wolfram. Its source and the detailed supply chain is provided by the manufacturer upon request. Subject to change without notice. Errors and omission excepted

Open the catalog to page 17
ManualHalfbridge Transducer - 18

Page 18/19 Manual halfbridge Transducer

Open the catalog to page 18
ManualHalfbridge Transducer - 19

Left blank for notes Subject to change without notice. Errors and omission excepted

Open the catalog to page 19

All PETER HIRT GmbH catalogs and technical brochures

  1. Transducer

    96 Pages

  2. Cable-Module

    2 Pages