Catalog excerpts
soft starter and dc brake VersiComb II Safe [12 — 60A] two-phase controlled soft start integrated by-pass relay reduction of starting current peaks DC braking integrated braking contactor integrated standstill detection monitoring of stopping time suitable for all asynchronous motors suitable for IE1, IE2 and IE3 motors self-optimizing soft start and braking CANopen on board degree of protection IP20 plugable push-in control terminals meets trad assoc. requirements for PL =c, acc. to EN13849-1:2008 soft starter and dc brake VersiComb II Safe [12 — 60A] Typical Applications: centrifuges, saws, milling machines, shakers vibration machines, hydraulic presses industrial dryers, grinding machines edge pressing machines, deburring machines meat grinders, mixers, other Relay and firing impulse supply parameterization via keypad or CAN-Bus motor auto tuning potential-free control inputs and outputs TVR or current controlled soft start motor temperature monitoring (PTC, KTY, PT1000) device protection motor protection tool speed monitoring (external speed sensor required) device fault relay (safety relevant) summary fault relay 24V for Control inputs CAN high CAN low CAN high CAN low External rotary encoder X3:3 Safety input X3:4 Start / Stop Safety input X3:5 Acknowledgement Collective X3:6 External standstill monitoring Saftey input X3:7 Motor temperature sensor X3:8 adaptor for VC II Safe 12A-37A for mounting onto DIN rail (order nr: 29000.29700) X1:43 Standstill signalling relay X1:44 (Safety relay) X1:53 Ramping up relay X1:54 (Safety relay) X1:33 Device fault X1:34 (Safety relay) Motor current detection Motor voltage detection Typ designation IE3-motor rating at 400V mains voltage motor rating at 400V mains voltage mains / motor voltage acc. to DIN EN 50160 (IEC 38) control voltage order number 480V order number 575V X1:23 Collective fault X1:24 X1:13 Operational state X1:14
Open the catalog to page 1soft starter and dc brake VersiComb II Safe [12 — 60A] Technical data mains / motor voltage acc. to DIN EN 50160 (IEC 38) rated device current starting section Ie max. starting / braking current (6x Ie) IE3-motor rating at 400V mains voltage motor rating at 400V mains voltage switching cycle per hour at tan/tbr=10s with 3x INenn each max. power dissipation - during operation at max. start frequency - only control voltage I²t(125°) (A²s) - thyristors starting time current limit starting/braking current max. braking time contact loading of output relays max. cross-sectional area for...
Open the catalog to page 2All PETER Electronic catalogs and technical brochures
-
VBMS [20A]
2 Pages
-
Braking Devices
6 Pages
-
Soft starters
8 Pages
-
AC Drives VersiDrive i....
29 Pages
-
General Catalogue 2012
114 Pages