Overview:
This document provides technical specifications and operational guidelines for the VersiBrake L (LP) braking devices, suitable for asynchronous and mono-phase motors. It includes details on features, functions, type designations, technical data, and typical applications.

Features:
  • DC braking with one-way rectification.
  • Microcontroller-controlled operation.
  • Easy mounting, suitable for retrofitting.
  • Wear-resistant and maintenance-free.
  • Integrated braking contactor.
  • Available in case version (IP 20) and printed circuit-board version (IP 00).
  • Complies with DIN EN ISO 13849-1 for safety requirements.

Functionality:
  • Braking initiated via motor voltage detection and motor contactor.
  • Overload protection and braking current cutoff after motor standstill.
  • Automatic remanence time optimization and adjustable braking current (10-100%).
  • Potential-free output for motor contactor interlocking during braking.
  • Adjustable standstill threshold for different motor types.

Type Designations and Specifications:
  • Models: VB 230-6L, VB 230-25L, VB 230-30L, VB 400-6L, VB 400-25L, VB 400-30L.
  • Rated device current ranges from 6A to 30A.
  • Mains voltage: 220/240V or 380/415V ±10%, 50/60Hz.
  • Order numbers provided for both case and printed circuit-board versions.

Technical Data:
  • Power draw of electronics: 3 VA.
  • Recommended motor current varies by model.
  • Max braking frequency and I²t-value specified for each model.
  • Braking voltage ranges from 0 to 220VDC.
  • Max braking time: 12 seconds.
  • Contact rating: 3A/250VAC; 3A/30VDC.
  • Ambient/storage temperature: 0°C to 45°C / -25°C to 75°C.

Applications:
  • Suitable for saws, conveyors, woodworking machines, grinding machines, and more.

Notes:
  • Consider higher starting and braking currents for IE3 motors.
  • Recommend sizing softstarters and braking devices one size higher for IE3 motors.

Connection Diagram:
  • Includes detailed connection instructions and terminal-phase connections.
  • Fault signaling contact and interlock features described.
See more

Catalog excerpts

Braking Devices VersiBrake L (LP) [6 — 30A]-1

Braking Devices VersiBrake L (LP) [6 — 30A] DC braking with one-way rectification suitable for all asynchronous motors and for mono phase motors controlled by microcontroller easy mounting, also for retrofitting into existing plants wear-resistant and maintenance-free integrated braking contactor printed circuit-board version with fault signaling contact for snap-on mounting onto 35mm DIN rail degree of protection: case version IP 20, printed circuit-board version IP 00 meets trade assoc. requirements for PL = b, acc. to DIN EN ISO 13849-1 Typical Applications: saws conveyors woodworking machines grinding machines others start braking via detection of motor voltage and via motor contactor (double safety) overload protection braking current cutoff after motor standstill braking current control automatic remanence time optimization braking current infinitely adjustable 10-100% potential-free output for motor contactor interlocking during braking; also usable to energize the star contactor during braking standstill threshold adjustable, individual adaptable to different motor types Type designation rated device current mains voltage according to DIN EN 50160 (IEC 38) only available with circuit-board version (LP) order number case version (L) order number printed circuit-board version (LP) Please observe supplementary sheet with dimensioning rules! www.peter-electronic.com

 Open the catalog to page 1
Braking Devices VersiBrake L (LP) [6 — 30A]-2

Braking Devices VersiBrake L (LP) [6 — 30A] Technical data power draw of electronics recommended for rated motor current up to recommended for rated motor current on IE3 motors rated device current max. braking frequency at braking time of 5s I²t-value of power semiconductors in A²s braking voltage contact rating (control relay) delay time for reduction of residual e.m.f. self-optimizing in the range between 0,2 … 2s max. cross-sectional area for connection ambient /storage temperature Note: Please pay attention and consider for the operation of IE3 motors while dimensioning of softstarters and...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.