Catalog excerpts
Variable Speed Drives VersiDrive i... Electronic drives
Open the catalog to page 1General installation notes 2-3 AC drives for Single-phase AC motors Accessories AC drives VersiDrive i 25 Frequently asked questions 26
Open the catalog to page 2Frequency inverters from PETER electronic are an excellent method to control the speed of a.c. motors or three-phase motors. What makes them stand out is their very easy and user-friendly operability. The new type series „VersiDrive i" is the flagship of our inverter range. It is especially worth mentioning that the complete VersiDrive i product line features high-quality details - despite or just because of its attractive price. The whole VersiDrive i series is obtainable in rating classes that range from 0.37 to i6okW and VD i .../E2, i-phase, 0.37 to 2.2kW, degree of protection IP20 - or...
Open the catalog to page 3General installation notes Supply voltage Make sure that the mains voltage corresponds with the supply voltage Power switch Fuses and mains contactor Install a protective device (fuse or overload circuit-breaker) between the mains and the inverter. Do not use the overload circuit-breaker as an ON-OFF switch. Depending on the application, it may additionally be necessary to install a power contactor. The power contactor must not be used for switching the inverter on and off. Line reactor Line reactors reduce harmonic currents and voltage drops. Mains filter A mains filter is to be used if...
Open the catalog to page 4General installation notes Motor cable Output filter For cable lengths >5om (shielded) and >ioom (unshielded), an output filter (motor choke, dv/dt-filter, sinewave filter) Motor cabel
Open the catalog to page 5□ small inverters for single-phase capacitor motors □ easy programming and connection □ fixed frequencies adjustable □ max. rotating field frequency 120Hz □ integrated braking chopper (at i,ikW) □ integrated mains filter □ serial communication with Modbus RTU □ control and setpoint entry via terminals and operating unit □ potential-free control and signalling contacts □ detailed trouble check with parameter „o" □ memory stick with copying function □ remote control module □ input and output module □ software for parameterization and operating Typical Applications: Operating unit monitoring...
Open the catalog to page 6Connection Diagram: Mains voltage Line reactor Mains filter Start - Stop Braking resistor Relay contact Subject to change without notice.
Open the catalog to page 7□ small inverters for single-phase capacitor motors □ easy programming and connection □ fixed frequencies adjustable □ max. rotating field frequency 120Hz □ integrated braking chopper (at i,ikW) □ integrated mains filter □ serial communication with Modbus RTU □ control and setpoint entry via terminals and operating unit □ potential-free control and signalling contacts □ detailed trouble check with parameter „o" □ memory stick with copying function □ remote control module □ input and output module □ software for parameterization and operating Typical Applications: Operating unit monitoring...
Open the catalog to page 9Connection Diagram: Mains voltage Line reactor Mains filter . Braking resistor Relay contact Subject to change without notice.
Open the catalog to page 10□ easy programming and connection □ voltage vector control □ fixed frequencies adjustable □ max. rotating field frequency 500Hz □ Integrated braking chopper (from 2,2kW up) □ integrated mains filter □ serial communication with Modbus RTU □ control and setpoint entry via terminals and operating unit □ potential-free control and signalling contacts □ detailed trouble check via parameter „o" Options: (please see accessories) □ memory stick with copying function □ remote control module □ input and output module □ software for parameterization and operating Typical Applications: conveying sytems...
Open the catalog to page 12Connection Diagram: Mains voltage Line reactor Mains filter Start - Stop Braking resistor Relay contact Subject to change without notice.
Open the catalog to page 13□ small design for degree of protection IP66 □ easy programming and connection □ voltage vector control □ fixed frequencies adjustable □ max.rotating field frequency 500Hz □ integrated braking chopper (from 2,2kW up) □ integrated mains filter □ serial communication with Modbus RTU □ control and setpoint entry via terminals and operating unit □ potential-free control and signalling contacts □ integrated setpoint potentiometer □ detailed trouble check with parameter„o" Options and braking resistors: (please see accessories) □ input and output module □ software for parameterization and...
Open the catalog to page 15Mains voltage Subject to change without notice.
Open the catalog to page 16□ Open Loop vector control (200% start torque) □ Closed Loop Encoder control (plug-In) □ Open and Closed Loop control for synchronous motors □ max. rotating field frequency 500Hz □ safety stop according to IEC 61508 SIL2 □ integrated braking chopper □ integrated mains filter □ integrated Modbus RTU and CANbus □ control and setpoint entry via terminals, operating units an bus systems □ sensorless speed and torque control □ potential-free control and signalling contacts □ detailed trouble check with parameter „o" Options: (please see accessories) □ remote control module □ additional input and...
Open the catalog to page 18Connection Diagram: Mains voltage Line reactor Analog input Braking resistor Subject to change without notice.
Open the catalog to page 19□ Open Loop Vector Control (200% start torque) □ Closed Loop Encoder control (plug-In) □ Open and Closed Loop control for synchronous motors □ max. rotating field frequency 500Hz □ safety control according to IEC 61508 SIL2 □ integrated braking chopper □ built-in DC reactor as standard □ integrated mains filter □ integrated Modbus RTU module and CANbus □ control and setpoint entry via terminals, operating units and bus systems □ sensorless speed and torque control □ potential-free control and signalling contacts □ detailed trouble check with parameter „o" Options: (Please see accessories) □...
Open the catalog to page 21Connection Diagram: Mains voltage Line reactor Analog input Braking resistor Subject to change without notice.
Open the catalog to page 22Open Loop Vector Control (200% start torque) Closed Loop Encoder control (plug-In) Open and Closed Loop control for synchronous motors max. rotating field frequency 500Hz safety control accordingto IEC 61508 SIL2 integrated braking chopper integrated mains filter integrated Modbus RTU module and CANbus □ control and setpoint entry via terminals, operating units and bus systems □ sensorless speed and torque control □ potential-free control and signalling contacts □ detailed trouble check via parameter„o" Options: (please see accessories) □ Remote control module □ Input and output module □...
Open the catalog to page 24All PETER Electronic catalogs and technical brochures
-
VBMS [20A]
2 Pages
-
Braking Devices
6 Pages
-
Soft starters
8 Pages
-
General Catalogue 2012