Product Overview:
The Pertronic Network System is designed to connect up to 99 nodes using a two-wire high-speed RS485 data communication loop. This system is compatible with Pertronic F100A or F120A Fire Alarm Control Panels, with a maximum of 32 nodes being these specific panels. The network is fault-tolerant, ensuring that a single break or short-circuit does not affect system operation. Configuration and programming of the network can be done via a computer connected to any Network Card. Events from one panel can be mapped to others for indication or activation, with up to 128 network inputs for F120A panels and 64 for F100A panels and network LCD or LED Mimics.
Network Card (NETCARD) Features:
  • Compatible with F120A panels with firmware V3.12 or greater and F100A panels with firmware V4.54 or greater.
  • High-speed isolated communication bus between nodes.
  • Supports up to 1 km distance between nodes using twisted-pair cable.
  • Earth fault monitoring for individual network links.
  • Fibre-optic option available for any network node link.
  • Network Control Unit (NCU) with a 240 x 128 pixel graphics LCD display for network information control.
  • Mini-Mimic displays network or alarm information on a 2 x 40 character LCD display, with a maximum of 8 per Network Card.
  • Network LED Mimic supports up to 128 individual open-collector outputs, with a maximum of 8 per Network Card.
  • Graphics interface for integration with the Pertronic ‘FireMap’ Graphics System.
  • Printer/Pager Interface for outputting network data to a serial printer or paging system.
  • Plug-in wiring terminals for easy installation.
Specifications:
  • Network Card Dimensions: 166 x 96 x 30 mm (L x W x H).
  • Network Control Unit Dimensions: 375 x 232 x 50 mm (W x H x D).
  • LCD Mini-Mimic Dimensions: 236 x 105 x 31 mm (W x H x D).
  • Cable Terminations: 0.5 mm² to 2.5 mm² plug-in.
  • Operating Temperature Range: -10 °C to 55 °C.
  • Relative Humidity: 0% to 95% RH, non-condensing.
  • Power Supply: 27 VDC, typically direct from the panel.
  • Standby Current at 27 VDC: Network Card 54 mA, Network Control Unit 15 mA, LCD Mini-Mimic 5 mA.
Ordering Information:
  • NETCARD: Network Card for F100/F120 Panels/LED Mimics.
  • NETCD-NCU: Network Card for Network Control/Display Unit.
  • NETCU-A: Network Control Unit in F120A Mimic Case, AUS.
See more

Catalog excerpts

NETCARD-1

Networking Fire Alarm Control Panels Product Overview: The Pertronic Network System can connect up to 99 nodes using the two-wire high-speed RS485 data communication loop connected to network cards at each panel or display. Up to 32 nodes can be Pertronic F100A or F120A Fire Alarm Control Panels. The network is fault tolerant so that a single break or short-circuit anywhere in the communication loop will not compromise the operation of the system. A computer may be connected to any of the Network Cards to configure and program the entire ring of Network Cards. Events at one panel may be mapped as network inputs to one or more of the other panels for indication or to activate any outputs. Up to 128 network inputs may be used for F120A panels and up to 64 network inputs for F100A panels and network LCD or LED Mimics. Network Card (NETCARD) Features: » » » » » » » » » » » » Compatible with F120A panels fitted with firmware V3.12 or greater Compatible with F100A panels fitted with firmware V4.54 or greater High speed isolated communication bus between each network node 1 km distance between network nodes using twisted-pair cable Earth fault monitoring for individual network links Fibre-optic option for any network node link Network Control Unit (NCU) – displays and controls all network information, including direct control of individual panels. 240 x 128 pixel graphics LCD display. One per Network Card Mini-Mimic – displays all network information or Alarms only information. 2 x 40 character LCD display. Maximum of 8 per Network Card Network LED Mimic – drives up to 128 individual open-collector outputs. Maximum of 8 per Network Card Graphics interface – interfaces between the network and the Pertronic ‘FireMap’ Graphics System. One per Network Card Printer / Pager Interface – outputs network data to a serial printer or paging system. One per network card Plug-in wiring terminals for fast

 Open the catalog to page 1
NETCARD-2

» Network Card Dimensions » Network Control Unit (NCU) Dimensions » LCD Mini-Mimic Dimensions » Cable Terminations » Operating Temperature Range » Relative Humidity » Power Supply » Standby Current @ 27 Vdc 0.5 mm2 to 2.5 mm2 plug-in -10 °C to 55 °C 0 % to 95% RH, non-condensing 27 Vdc, typically direct from the panel Network Card 54 mA Network Control Unit 15 mA Ordering Information: Product Code

 Open the catalog to page 2

All Pertronic Industries Pty Ltd catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.