GAS SAFETY
5Pages

{{requestButtons}}

Catalog excerpts

GAS SAFETY - 1

GAS SAFETY PRODUCTS FOR CIVIL INSTALLATION GAS DETECTION SERIES ZEFIRO PRODUCTS FOR INDUSTRIAL INSTALLATION GAS DETECTION CONTROL UNITS 6-9 DIN modular units GAS DETECTION CONTROL UNITS IN SWITCHBOARDS GAS SENSORS IP44 SENSORS IP55 SENSORS IP55 SENSORS SOLENOID VALVES Class “A” type-approved NC valves NO Normally Open valves NC Normally Closed valves Special voltages upon demand

Open the catalog to page 1
GAS SAFETY - 2

GAS DETECTION WALL-MOUNTING KITS CEI 216-8 (semi-recessed), EN 50194 (explosive gases), EN 50291 (toxic gases) EN 50270

Open the catalog to page 2
GAS SAFETY - 3

GAS SAFETY WALL-MOUNTED AND/OR SEMI-RECESSED GAS DETECTION ZEFIRO CODE Wall-mounted and/or Semi-recessed natural gas (CH4) detector with BUS output series “ZEFIRO” Power supply 230V a.c. 50-60Hz 1 potential-free changeover contact output: 8(2)A/250Va.c. Microprocessor with fume selection program to prevent false alarms Microprocessor with timer to signal product service every 5 years Remote sensor recognition (BUS system) Digital BUS output for signaller control (max 15) Interconnection length max 800m (2x1.5 sq.mm) Alarm memory Fault indicator LED Gas concentration LED on 3 signalling...

Open the catalog to page 3
GAS SAFETY - 4

GAS SAFETY WALL-MOUNTED AND/OR SEMI-RECESSED GAS DETECTION ZEFIRO CODE Wall-mounted and/or Semi-recessed natural gas (CH4) detector with BUS output series “ZEFIRO” Power supply 230V a.c. 50-60Hz 1 potential-free changeover contact output: 8(2)A/250Va.c. Signalling buzzer 85dB at 1m ON indicator LED Fault indicator LED Gas presence indicator LED Intervention level 5000 ppm 10% LIE Wall-mounted IP 42 Dimensions (LxWxH) 120 x 40 x 82 Semi-recessed installation with accessory IP 40 Dimensions (LxWxH) 120 x 27.5 x 82 Wall-mounted and/or Semi-recessed LPG gas detector with BUS output series...

Open the catalog to page 4
GAS SAFETY - 5

GAS SAFETY WALL-MOUNTED GAS DETECTION CODE Wall-mounted carbon monoxide (CO) and natural gas (CH4) detector The detector can detect two gases: natural gas (CH4) and carbon monoxide (CO) Intervention sensitivity: - natural gas at 10% of the lower explosion limit - carbon monoxide, when the maximum allowed 300ppm CO concentration is exceeded, or rather in case low but damaging concentrations 30ppm for 2 hours persist for long periods in the premises. Power supply 230V a.c. 50-60Hz 2 potential-free changeover contacts output: 5(2)A/250Va.c. Natural gas catalytic sensor Natural gas intervention...

Open the catalog to page 5

All PERRY ELECTRIC catalogs and technical brochures