Catalog excerpts

Thermal Analysis Key Features • Compact footprint with optional autosampler • High performance balance and furnace for maximum accuracy and precision • Top loading balance for easy sample loading and unloading • Furnace and balance isolated from operators to minimize maintenance, ensuring uptime • Fast cooling reduces cycle times improving productivity • Integrated mass flow controller extends applications flexibility • Optional 45 position autosampler allows unattended operation, improving productivity • Pyris software suite is easy to use and feature rich for maximum application flexibility Thermal analysis solutions and beyond At PerkinElmer, we’re committed to the future of thermal analysis. We prove it with our new TGA 4000, which delivers the answers you need with less effort than you ever thought possible. Whether you’re researching new materials or ensuring the quality of your products, the TGA 4000 delivers great results, all day and every day. Fast, accurate, precise Your success starts with our compact ceramic furnace, which provides the temperature control needed for accurate, precise results and the fast sample purge and cool down required for short cycle times. Forced air and liquid cooling further reduce cycle times allowing you to run more samples in less time. The ceramic construction is inert and corrosion resistant for improved ruggedness, permitting a wide range of reactive gases for enhanced applications flexibility. A large isothermal zone keeps your samples at the same temperature as the furnace throughout a temperature program providing you with results, even with large samples up to 1500 mg weight or 180 µl volume.
Open the catalog to page 1
4000 Small furnace volume Sensitive top-loading balance Rugged, corrosion resistant ceramic furnace Sample thermocouple Fast cooling furnace Sample purge gas Forced air cooling Thermally isolated balance Balance purge gas provides constant environment and protection Stable and robust A sensitive and stable top loading balance makes it easy for anyone to load and unload samples. The balance is isolated from operators to protect it from damage, and protected from sample debris by an over pressure balance purge gas. Thick stainless steel walls act as a large heat sink thermally isolating the...
Open the catalog to page 2
Reliable automation The long-established software benchmark To enhance sample throughput or simply make your TGA 4000 even easier to operate, select the optional high capacity 45-position autosampler. For ultimate productivity, a unique two piece carousel allows removal and reloading of one carousel section while the other keeps going. Sample changing reliability is a must for any autosampler and is also where the TGA 4000 excels. Patented (U.S. 6,203,760) gripper technology uses smart Shape Memory Alloy (SMA) to transfer your samples securely, every time. For the fastest cycle times, Pyris...
Open the catalog to page 3
Calcium Oxalate Calcium oxalate is a well characterized materia that has three distinct weight loss events that occur during heating: H20, CO, C02. To verify ment was conducted using 15 mg of calcium oxalate with a nitrogen purge gas. The samples were run using a scanning rate of 20 "C/minute. As you can see from the figure, the weight loss events recorded by the TGA 4000 are extremely comparable with the theoretical values of calcium NOTE: Specs measured Copper Sulfate Hydrate Copper Sulfate (CuS04) exists as a series of compounds which differ in regard to their degree of hydration. When...
Open the catalog to page 4
Hyphenation capabilities Uptime and longevity for your new investment Do you want to get a better understanding of the chemical composition of your evolved sample gas? If you answered yes, we have the perfect solution for you. PerkinElmer allows you to seamlessly interface your PerkinElmer® TGA to a PerkinElmer FT-IR, Mass Spectrometer or GC/MS. The gas line interfaces are optimized for PerkinElmer instruments with complete systems supported by our global service network ensuring your security and confidence. PerkinElmer channel partners provide additional interfaces should you need to...
Open the catalog to page 5
For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs Copyright ©2009-2012, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners
Open the catalog to page 6All PerkinElmer catalogs and technical brochures
-
TGA 8000 Brochure
8 Pages
-
Adulterant Screen Solutions
8 Pages
-
OilExpress Family Brochure
8 Pages
-
Flexar SQ 300 MS Brochure
8 Pages
-
AxION iQT GC/MS/MS
2 Pages
-
Hyphenated Technology Guide
10 Pages
-
Spectrum Two FT-IR Spectroscopy
12 Pages
-
Clarus SQ8 GC/MS Brochure
12 Pages
-
NexION 350 ICP-MS
12 Pages
-
Onesource Overview Brochure
8 Pages
-
XRpad 4336
2 Pages
-
GC SNFR Olfactory Port
2 Pages
-
AxION DSA Brochure
8 Pages
-
AxION 2 TOF Brochure
8 Pages