1. Catalogs
  2. PerkinElmer
  3. NexION 350 ICP-MS

NexION 350 ICP-MS

NexION 350 ICP-MS
1 / 12 PagesView full catalog

NexION 350 ICP-MS

Product catalog summary
Overview
The NexION 350 ICP-MS is engineered to boost laboratory efficiency and productivity with its rapid, precise, and adaptable analysis capabilities. It operates in three modes—Standard, Collision, and Reaction—allowing for customized sensitivity and speed without sacrificing accuracy.
Key Features
  • Data Acquisition: Capable of capturing 100,000 data points per second, ideal for analyzing fast transient signals and characterizing nanoparticles.
  • Triple Cone Interface: Ensures a focused ion beam, reducing maintenance needs and enhancing signal stability.
  • Quadrupole Ion Deflector: Filters out neutrals, enhancing stability and reducing background interference.
  • Universal Cell Technology: Provides three operational modes for optimal interference removal and detection limits.
Operational Modes
  • Standard Mode: Offers high sensitivity without interference correction.
  • Collision Mode: Utilizes non-reactive gas to lower the kinetic energy of interfering ions.
  • Reaction Mode: Uses reactive gases for superior interference removal.
Maintenance and Usability
  • Low Maintenance: Features like the Triple Cone Interface and Quadrupole Ion Deflector minimize cleaning and downtime.
  • Software: Syngistix for ICP-MS Software provides an intuitive interface for method development and quality control, with pre-set methods and templates.
  • Design: Compact benchtop design with no rear connections saves space and supports various sample introduction systems.
Applications
The NexION 350 ICP-MS is versatile, suitable for environmental testing, geochemical analysis, and industries requiring high interference removal, such as semiconductor and biomonitoring.
Scheduler
The Scheduler feature in the Syngistix software automates instrument optimizations and procedures, enhancing workflow efficiency and reducing operator intervention, thus improving data reliability.
Reporter Function
The software includes a calibration reporting function that provides real-time updates on detection limits and background equivalent concentrations, facilitating faster decision-making and reliable data generation.
Logbook
This feature allows users to review the complete instrument performance history, displaying previous optimization data and changes, aiding in correlating sensitivity to results and tracking performance data in real time.
Review Files
A dialog box displays all files in the workspace, allowing users to view methods, sample lists, and optimized files at a glance before starting a run.
Application-Specific Environments
The software offers application-specific plug-ins and integration with external software packages to simplify tasks like nanoparticle analysis and speciation.
SmartTune Express
SmartTune Express automates tuning procedures and specifications before a run, ensuring system specifications are checked and optimized, eliminating inefficiencies, and ensuring accurate results.
Speciation Analysis
The NexION 350 ICP-MS can integrate with LC, GC, and IC systems for complete separation and determination of individual metal compounds, controlled by Chromera software for accurate speciation analysis.
Nano Application Module
This module is dedicated to nanoparticle analysis, offering real-time single particle acquisition and fast data processing, determining particle composition, concentration, size, and distribution in less than a minute.
Data Transfer and Analysis
LimsLink software automates data transfer to LIMS systems, while TIBCO Spotfire software allows for advanced data analysis and visualization, reducing time and complexity.
Available Configurations
The NexION 350 ICP-MS is available in several configurations, each suited for different applications, from routine geochemical analysis to semiconductor industry needs.
Lab Services
PerkinElmer OneSource offers a comprehensive suite of services, including instrument service, repair, and method development, to optimize lab efficiencies and support scientific workflows.
See more

Catalog excerpts

NexION 350 ICP-MS-1

NexiON 350 ICP-MS PerkinElmer Maximum throughput. Minimum downtime. Optimum insight. FortheBetter

 Open the catalog to page 1
NexION 350 ICP-MS-2

When your instrument is more efficient and productive, so too are your scientists and your lab. And nothing puts the flow in your workflow better than the NexION® 350 ICP-MS. Operation is simple. Virtually any sample can be analyzed. And results are faster and more accurate for greater confidence. Three modes of operation—Standard, Collision and Reaction—give you ultimate application flexibility and allow you to select the level of sensitivity you need without compromising speed. The Speed To See New Things With a data acquisition rate 10 times faster than any other ICP-MS on the market, the...

 Open the catalog to page 2
NexION 350 ICP-MS-3

The path to more confident results The unique ion path in the NexION 350 ICP-MS creates the cleanest, most stable environment of any instrument for more accurate and consistent results. From its robust sample introduction systems all the way through to its industry-leading detector, every component has been designed for greater flexibility, optimum performance, and superior laboratory efficiency. Quadrupole Ion Deflector filters off neutrals for greater stability and consistency. Three quadrupoles to maximize sensitivity for every element in a run. Three cones (sampler, skimmer AND hyper skimmer)...

 Open the catalog to page 3
NexION 350 ICP-MS-4

PerkinElmer was the first company to bring together the simplicity and convenience of a collision cell and the exceptional detection limits of a true reaction cell in a single ICP-MS instrument. Not only does the NexION 350 give you the choice of these two most powerful polyatomic interference-removal techniques, it also features a Standard setting as part of its patented Universal Cell Technology™ (UCT), allowing the instrument to be run in three different modes to suit your required level of interference removal and detection limits. Three Modes—Complete Flexibility With its three modes of...

 Open the catalog to page 4
NexION 350 ICP-MS-5

STANDARD mode IDEAL USES detection limits REACTION mode— with a scanning quadrupole INTERFERENCE REMOVAL COLLISION mode— with Kinetic Energy Discrimination (KED) The cell gas is turned off and the system works like a non-cell instrument, providing a level of sensitivity equal to Collision or Reaction mode for elements not requiring interference correction. A non-reactive gas is introduced into the cell to collide with interfering ions with larger diameters, reducing their kinetic energy so they may be removed through Kinetic Energy Discrimination. A highly reactive gas (or gasses) is introduced...

 Open the catalog to page 5
NexION 350 ICP-MS-6

Simultaneous dual mode detector— Provides over 10 orders of dynamic range and measures both high- and low-level analytes simultaneously. Also delivers the fastest data acquisition rates of any ICPMS instrument (100,000 data points per second to keep up with the scan speed of the analyzing quadrupole), making the NexION 350 ideal for the nanomaterials field. Analyzing Quadrupole—Offers the highest analytical mass range available (all the way up to 285 amu) and exceptionally fast scanning for rapid peak hopping. Large, open, easily accessible sample introduction area—Accommodates a wide variety...

 Open the catalog to page 6
NexION 350 ICP-MS-7

Universal Cell Technology—Offers three modes of operation (Standard, Collision or Reaction) depending on the level of performance required. Switching modes is quick and easy so users can select their required level of performance without compromising speed. Triple Cone Interface—Produces the most tightly focused ion beam in the industry, reducing build-up on internal components (particularly the Quadrupole Ion Deflector) so maintenance and cleaning are virtually eliminated. Quadrupole Ion Deflector—Allows only ions of a specified mass range to pass into the Universal Cell, enhancing sensitivity...

 Open the catalog to page 7
NexION 350 ICP-MS-8

With a simple, clear, intuitive interface that mirrors your workflow, Syngistix™ for ICP-MS Software simplifies every interaction with the NexION 350 ICP-MS. The left-to-right, icon-based design offers easy navigation, walking you through every step of an analysis: starting the instrument, optimizing the system, creating methods and sample lists, performing the run, and reviewing results. So no matter what your analysis type—qualitative, semi-quantitative, quantitative or specialized (isotope-ratio, isotopedilution)—Syngistix for ICP-MS Software offers all the tools to help you generate faster,...

 Open the catalog to page 8
NexION 350 ICP-MS-9

Flexible Quality Control Checks Monitoring calibration, checking standard responses and taking action to correct any problems with an analysis can all be done using the software’s automated quality control checking feature. Flexible and customizable, it ensures good quality data even when the instrument is being run unattended. SmartTune Express Designed for maximum productivity and effortless operation, SmartTune™ Express automatically sets up all your tuning procedures and specs before a run, initiating the analysis if all parameters are met, or performing a system optimization if not. Programmed...

 Open the catalog to page 9
NexION 350 ICP-MS-10

FAST, ACCURATE NANOPARTICLE CHARACTERIZATION The emerging and rapidly growing field of nanotechnology has two application areas, both of which can benefit from the unique capabilities of the NexION 350 ICP-MS. Nanoparticle Detection With the increased use of nanotechnology in consumer products, industrial applications and healthcare technology, nanoparticles are becoming ever more prevalent in the environment and it is becoming increasingly important to assess their fate, transformation and transportation in different matrices, whether soils, potable water and wastewater, and their resulting...

 Open the catalog to page 10
NexION 350 ICP-MS-11

NEXION 350 ICP-MS AVAILABLE CONFIGURATIONS MODEL # SUITED APPLICATIONS Simple analyses requiring no interference-removing correction capabilities, including routine geochemical analysis Single-channel Universal Cell (1 gas line) or Dual-channel Universal Cell (2 gas lines, not ammonia) General purpose, particularly environmental Dual-channel Universal Cell (2 gas lines) Analyses requiring availability of KED and/or scanning quadrupole at all times, particularly biomonitoring Dual-channel Universal Cell (2 gas lines) optimized for sensitivity Designed specifically for the semiconductor industry...

 Open the catalog to page 11

All PerkinElmer catalogs and technical brochures

  1. XRpad 4336

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.