1. Catalogs
  2. PerkinElmer
  3. Hyphenated Technology Guide

Hyphenated Technology Guide

Hyphenated Technology Guide
1 / 10 PagesView full catalog

Hyphenated Technology Guide

Product catalog summary
Introduction
Hyphenated technology refers to the integration of two analytical instruments to enhance analytical capabilities. This guide discusses the coupling of Thermogravimetric Analysis (TGA) with techniques such as Fourier Transform Infrared (FT-IR), Mass Spectrometry (MS), and Gas Chromatography/Mass Spectrometry (GC/MS) for Evolved Gas Analysis (EGA).
TG-IR
The TG-IR system combines a Thermogravimetric Analyzer with an Infrared Spectrometer, facilitating the identification of gases evolved during sample heating. The PerkinElmer TL8000 transfer line ensures efficient gas transport, improving data quality. Applications include identifying residual solvents in pharmaceuticals and analyzing combustion products.
Hiden Analytical MS Systems for TG-MS
Combining TGA with MS allows for the detection of low-level impurities. Hiden Analytical MS systems offer various configurations with features like variable ionization and user-friendly software, useful in quality control and safety applications, such as detecting residual solvents in pharmaceuticals.
TG-MS
The TG-MS system, using PerkinElmer's Pyris 1 TGA and Clarus SQ 8 MS, provides sensitive real-time analysis for detecting residual solvents and measuring additives in polymers. It offers flexible options for transfer lines, balancing performance and cost.
TG-GC/MS
Incorporating gas chromatography into the TG-MS setup allows for the separation of overlapping events and detection of low-level impurities. PerkinElmer TG-GC/MS systems offer varying levels of sensitivity and precision, suitable for complex mixture analysis.
TG-IR-GC/MS
This advanced setup combines TG, IR, and GC/MS to analyze unknown mixtures, identifying primary components and contaminants. The TL9000 transfer line facilitates gas movement between instruments, providing comprehensive analysis capabilities, beneficial for regulatory compliance and competitive analysis.
Conclusion
Hyphenated technologies like TG-IR, TG-MS, TG-GC/MS, and TG-IR-GC/MS enhance laboratory capabilities for advanced material analysis across various applications.
See more

Catalog excerpts

Hyphenated Technology Guide-2

HYPHENATED TECHNOLOGY GUIDE Coupling, or hyphenating, two instruments can uncover results and insights not possible with individual techniques. The power of your analysis therefore becomes greater than the sum of its parts. • o you want to better understand how a material degrades D or what gases evolve when it burns? The technique used to answer these questions is called Evolved Gas Analysis. Our Thermogravimetric (TG) instruments can be coupled to Fourier Transform Infrared (FT-IR), Mass Spectrometry (MS), or Gas Chromatography/Mass Spectrometry (GC/MS) to provide you with greater knowledge....

 Open the catalog to page 2
Hyphenated Technology Guide-3

TG-IR Figure 1. The TL8000 transfer line couples a Frontier FT-IR to a TGA. The combination of a Thermogravimetric Analyzer (TGA) with an Infrared Spectrometer (TG-IR) is the most common type of Evolved Gas Analysis (EGA) in use today. By heating a sample on the TGA, a sample will release volatile materials or generate combustion components as it burns. These gases are then transferred to the IR cell, where the components can be identified. Because of its ability to detect functional groups, IR analysis allows greater understanding of the processes seen in the TGA. • Automatic importation of...

 Open the catalog to page 3
Hyphenated Technology Guide-4

Hiden Analytical MS Systems for TG-MS Figure 1. The Hiden Analytical HPR20 MS is shown connected to the PerkinElmer Pyris™ 1 TGA. Combining a Thermogravimetric Analyzer (TGA) with a Mass Spectrometer (MS) allows you to detect very low levels of impurities. By heating a sample on the TGA, it will release volatile materials or combustion components as it burns. These gases are then transferred to the MS for identification. The sensitivity of TG-MS is a powerful tool for quality control, safety, and product development. • STA6000 – DTA and TGA results simultaneously to 1000 °C • Pyris 1 TGA – our...

 Open the catalog to page 4
Hyphenated Technology Guide-5

TG-MS Figure 1. The TG-MS systems, with Pyris 1 TGA, a TL2000 heated transfer line and a Clarus® SQ 8 MS. PerkinElmer’s extensive product range means we can supply you with a complete system with one party service and support as well as the expertise and knowledge to help you use it effectively. The PerkinElmer transfer lines allow you to couple our sensitive Pyris™ 1 TGA to the PerkinElmer Clarus® SQ 8 GC/MS. We offer two options for transfer lines: the lower cost, TL2000 that couples only to the Pyris 1 TGA and the TL8500, which couples to our full range of Thermogravimetric Analyzers (TGA)...

 Open the catalog to page 5
Hyphenated Technology Guide-6

TG-GC/MS Figure 1. The Pyris 1 TGA coupled to the Clarus SQ 8 GC/MS gives the most sensitive method to identify evolved gases. Although TG-MS allows real-time monitoring, it can be confusing due to overlapping events and higher mass ions obscuring those of lower mass. By adding gas chromatography (GC) to the system, these events can be cleanly separated and very low levels of impurities detected. Heating a sample on the TGA causes a sample to release volatile materials or generate combustion components as it burns. These gases are then transferred to the GC, where the components can be collected...

 Open the catalog to page 6
Hyphenated Technology Guide-7

Collecting the material on a GC column and eluting it gives the following chromatogram. Using the data from the MS to identify the peaks, the progression on acids can be detected easily in the offgas. These components can not be isolated by TG-IR or TG-MS due to their low levels and the complexity of Figure 3. GC/MS on the gases evolved between 8 and 9 minutes and collected on the head of a GC column gave the chromatography seen on the bottom of the graph. MS analysis suggest that 15.8 is the acetic acid, which is confirmed above by running a standard of acetic, formic, and propanoic acids.

 Open the catalog to page 7
Hyphenated Technology Guide-8

TG-IR-GC/MS Figure 1. The TG-IR-GC/MS systems connects a TGA or STA to an FT-IR and then to a TG/MS is shown here using the TL9000 transfer line, Clarus GCMS, Frontier FT-IR, and Pyris 1 TGA. Hyphenating TG-IR-GC/MS is a powerful approach for analysis of an unknown mixture to determine its primary components and identify additives or contaminants. This information may be needed, for example, to evaluate a competitor’s product or to determine compliance with regulations. The PerkinElmer TL9000 transfer line is used to allow TG-IR-GC/ MS analysis on a sample by moving the off gases to the FT-IR...

 Open the catalog to page 8
Hyphenated Technology Guide-9

0.960 U08464 TRI ETHYLENE GLYCOL, DI EE N7 tlfl T f 0.947 U08716 TEREPHTHALIC ACID, ISOPROPYL METHYL ESTER 0.939 U08714 TEREPHTHALIC fiCID, ETHVL METHYL ESTER 0.936 U08715 TEREPHTHflLIC ACID, METHYL PROPYL ESTER 0.905 U09077 PTOLUIC ACID, A, A-DIBROMO-, ETHYL ESTER 0.890 U06254 BENZOIC ftCID, 4, 4PR-METHYLENEDI-, DIMETHYL ESTER 0.889 U05934 BENZOIC ACID, PISOTHIOCYANATO-, ETHYL ESTER 0.886 U06255 BENZOIC fiCID, 4,4PR-TRIMETHYLENE- DI-, DIMETHYL ESTER 0.884 U06256 BENZOIC ACID, 4,4PR-TETRflMETHYLENE- DI-, DIMETHYL ESTER 0.879 U06253 BIPHENYLDICflBBOXYLIC ACID, 4.4PR-, DIBOTYL ESTER 0.877 U07043...

 Open the catalog to page 9
Hyphenated Technology Guide-10

For more information, visit www.perkinelmer.com/hyphenation PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs Copyright ©2014, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009934A_01

 Open the catalog to page 10

All PerkinElmer catalogs and technical brochures

  1. XRpad 4336

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.