Product Overview
The GC SNFR Olfactory Port is an accessory designed to integrate with PerkinElmer GC/MS systems, offering quality, comfort, and ease of use with minimal training and maintenance. It is compatible with any capillary column in the GC and features an inert flow path, interchangeable glass nosepiece, humidified air control, built-in microphone, speech-to-text function, and an easy-to-control joystick. It overlays narration and odor intensity on the chromatogram and works with up to three different detectors.

Key Features
  • Integration with PerkinElmer GC solutions for aroma characterization.
  • Correlates human sensory evaluation with analytical data.
  • Ensures matching retention times for aroma experience and chromatography.
  • Speech-recognition software and joystick for inputting aroma intensity.
  • Graphical overlay of sensory data on chromatogram.

Benefits
The GC SNFR Olfactory Port provides a complete aroma characterization solution, integrating sensory evaluation with GC and GC/MS analytical data. It is a cost-effective solution for food, beverage, and fragrance manufacturers, enhancing the ability to characterize complex aromas.

PerkinElmer's Expertise
PerkinElmer offers a comprehensive range of instruments, reagents, and consumables, supported by a global network of factory-trained engineers. Their expertise ensures unmatched support and service, including preventative maintenance, validation support, and instrument repair.

Additional Products
  • Clarus Gas Chromatographs: Tailored models for robust and cost-effective solutions.
  • Clarus SQ 8 GC/MS: High-performance system with fast scanning quadrupole and sensitive detector.
  • TurboMatrix Headspace/Headspace Trap Samplers: High-sensitivity technologies for precise volatile-analysis applications.
  • TurboMatrix Thermal Desorption Systems: Models offering various throughput and technology for automated sample preparation.
See more

Catalog excerpts

GC SNFR Olfactory Port-1

GC SNFR Olfactory Port A complete aroma characterization solution that seamlessly integrates sensory evaluation with GC and GC/MS analytical data For food, beverage and fragrance manufacturers, we're making it easier to characterize aromas by delivering high performance and value in our latest GC accessory, the SNFR™ Olfactory Port. It's the only accessory of its kind that is both manufactured and supported by a manufacturer of complete gas chromatography solutions—PerkinElmer. Designed to integrate with PerkinElmer GC solutions, the affordable, flexible GC SNFR Olfactory Port delivers added incremental value when measuring and characterizing even the most complex aromas. The GC SNFR Olfactory Port enables you to correlate human sensory evaluation and analytical data, giving you the confidence you need to successfully move your batch forward. A Perfect Match Ensures Accurate Results As a sample elutes from the GC column, its flow is split between the GC/MS and up to two other detectors and the Olfactory Port. With SNFR, there are no delays. Its design ensures that retention times of the aroma experience and chromatography match—exactly. Built-in speech-recognition software and a simple joystick allow users to dictate their findings and input aroma intensity, providing both qualitative and quantitative reporting. The sensory data is overlaid graphically on the chromatogram for a complete and clear profile of your sample. The GC SNFR Olfactory Port from PerkinElmer. A simpler, more affordable solution for aroma characterization. Product Highlights The GC SNFR Olfactory Port is designed to integrate with PerkinElmer GC/MS systems and built for quality, comfort and ease of use, requiring minimal training and maintenance. • Works with any capillary column in the GC • Inert flow path • Interchangeable, adjustable glass nosepiece • Humidified air control in nosepiece • Built-in microphone to capture user narration • Speech-to-text function • Easy-to-control joystick • Overlay of narration and odor intensity on chromatogram • Works with up to three different detectors

 Open the catalog to page 1
GC SNFR Olfactory Port-2

The World's Most Complete GC Partner The only product of its kind developed and offered by an industry-leading provider of GC solutions, PerkinElmer’s GC SNFR Olfactory Port is part of a complete, integrated solution, from high-performance instrumentation to consumables and service. With a long history of successful partnerships in the food and beverage industries and a global reputation in headspace technology, we offer a single point of contact for everything from equipment purchasing to method development to application support. GC TECHNOLOGIES ENGINEERED AROUND YOU Customized to meet or exceed...