video corpo

Wicket Gate
22Pages

{{requestButtons}}

Catalog excerpts

Wicket Gate - 1

Electromechanical Wicket Gate PERCo. WHD-04 Operation manual

Open the catalog to page 1
Wicket Gate - 5

Assembly and operation manual 5.1.4 Main features of the wicket gate: mechanically durable; Օ high throughput capacity; built-in indication module (Red/Green status lights); Օ low power consumption; safe operational voltage 12 V DC; Օ a hydraulic damper to ensure smooth return of the swing panel into the home position; choice between single- and bi-directional operation (one of the passage directions can be blocked by a removable mechanical rotation limiter included in the standard delivery set); Օ a built-in SPS to keep the wicket gate operative during a mains failure; easy installed...

Open the catalog to page 5
Wicket Gate - 6

WHD-04 Wicket Gate 5.2.2 Overall and mounting dimensions are given in Figure 2. 5.2.3 The gate post (1) comes as a round tube with a foot to be floor installed by three anchor bolts. The top part of the gate post contains a rotation unit (11) with a fixed swing panel (2). Inside the gate post are a reset unit (a spring and a hydraulic damper), an electromagnetic locking device, a control logic board, optical rotation sensors, and an optical sensor of the locking device. The indication module (3) on the gate post displays the gate. 5.2.4. The control logic board (the CLB) comes as a printed...

Open the catalog to page 6
Wicket Gate - 7

Assembly and operation manual 5.2.6 The SPU (7) is designed as a separate device in a powder coated metal case with pull-resistant fasteners for wall mounting. Alternatively, the SPU can be desk-mounted. The SPU housing contains a power transformer, an SPU board and a 12 V battery of the standby power supply (the SPS). Located on the SPU front panel (Fig.3) are the following LED indicators: - "Power" AC mains (green); - "12V" ח gate post power supply 12 V DC (green); - "Battery" the SPU changeover to the SPS (red); - "Mode" ח the SPS charge status (green). Besides the LED indicators, there...

Open the catalog to page 7
Wicket Gate - 8

WHD-04 Wicket Gate Wireless remote control connector ACS connector Gate post power supply connector Bat/2A -220V/1A ^ (g>) ^ External power supply connector AC power cable input\ panel connector Control cable connector / Gate post power supply indicator CM AC mains Indicator SPS status Indicator Standby power supply Indicator Battery- Mode 12V Power External OFF Standby power supply ; toggle switch AC mains toggle switch 190 Figure 3. Switching and power unit 9

Open the catalog to page 8
Wicket Gate - 9

Assembly and operation manual 5.3.4 The wicket gate is operated by the CLB inside the gate post. When the power supply of the gate is on, the CLB performs the following test squence: - within the first 5 seconds generates a dual-tone audio signal from the remote control panel, runs the self-test program and initial setting of the processor; - verifies whether the swing panel is in the initial position (the swing panel blocks the passageway). If the testing is successful, the CLB allows to set the operating modes from the remote control panel. Otherwise, it generates an audio alert from the...

Open the catalog to page 9
Wicket Gate - 10

WHD-04 Wicket Gate RSU Rotation Sensors Unit; SPU ח Switching and Power Unit; LDS Locking Device Sensor; IM ח Indication Module; CLB Control Logic Board; LDD ח Locking Device Drive; RC Remote Control Panel; WRC ח Wireless Remote Control; ACS Access Control System; * optional LEGEND DESCRIPTION QUANTITY NOTES A1 Switching and Power Unit TTD-01.700.00 A2 Wireless Remote Control Unit MSRF-4 A3 Remote Control Panel H-05/2.100 A4 Control Logic Board WHD-04.800.00 A5 Tractive Electromagnet A6 Indication Module WHD-04.850.00 A7 Locking Device Sensor A8 Rotation Sensors Unit WHD-04.850.00 1 Control...

Open the catalog to page 10
Wicket Gate - 11

Assembly and opration manual 5.4 The wicket gate power supply 5.4.1 The wicket gate is powered by an SPU-located power supply unit with the following characteristics: input voltage 镗 220 V / 50 Hz single phase AC mains or 11.5-20.0 V DC from external power supply; output voltage ՗ unregulated voltage 10.5-20.0 V DC, max. current 1.5 A. 5.4.2 In the event of the AC power failurel*, the CLB automatically switches the gate power supply to the built-in SPS (sect. 5.3.4); the "POWER" green light on the SPS front panel goes out and the "Battery" red light flashes on. When the AC voltage is...

Open the catalog to page 11
Wicket Gate - 12

WHD-04 Wicket Gate TABLE 1 OPERATING MODE REMOTE CONTROL PANEL ACTIONS REMOTE CONTROL PANEL INDICATION INDICATION MODULE STATUS WICKET GATE STATUS 1 Single passage Press «-»» or «<-» buttons Green lights above the buttons «» and «<-» and red light above the «STOP» button Green light Single turn of the swing panel in either direction is available 2 Double passage Press «ח» and «<-» buttons simultaneously Green lights above the buttons «» and «<-» and red light above the «STOP» button Green light Double turn of the swing panel irrespective of the direction is available 3 Free passage Press...

Open the catalog to page 12
Wicket Gate - 13

Assembly and opration manual Assignment of the connector contacts '-\ 100000 ooooo VoooooJ RIGHT 1 STOP 2 LEFT 3 GND 5 PAS L 6 PAS R 7 POWER C 8 SHORT ID 10 SEN ALARM 11 INV BAT 12 SHORT I 13 CONTOUR 15 External power supply contacts +12 VDC 1 -12 VDC 2 Figure 5. The SPU socket connectors 5.6.5 Parameters of the "PAS R" and "PAS L" signais: the wicket gate is locked ("0") 镗 an open transistor collector (UMax < 0.8 B, Imax < 25 mA); the wicket gate is unlocked ("1") ՗ high-level DC voltage or a positive polarity pulse with duration min. 100 ms (closed transistor, Umax < 25 V, Imax < 0.1...

Open the catalog to page 13
Wicket Gate - 14

WHD-04 Wicket Gate 5.6.8 Additionally, the ACS is provided with the following status signais: "Power C" ՗ switchover to the SPS power supply (high-level signal, open collector); "Short ID" ՗ the system connector works (low-level signal, a jumper is installed on the "GND" contact); "INV BAT" inadmissible SPS discharge (high-level signal, open collector, closed transistor). 5.6.9 The ACS generates the "Short I" control signal setting the passage waiting time as infinite. The "Short I" signal must be transmitted prior and kept upon the SPU power-up. To set the passage waiting time from the...

Open the catalog to page 14