TTR-04.1 Operation manual
29Pages

{{requestButtons}}

Catalog excerpts

TTR-04.1 Operation manual - 1

Electromechanical Tripod Turnstile Opration manual

Open the catalog to page 1
TTR-04.1 Operation manual - 2

TTR-04.1 Electromechanical Tripod Turnstile Opration manual POCC. RU. MJ1 02. B00145

Open the catalog to page 2
TTR-04.1 Operation manual - 6

Operation manual Fig. 1. TTR-04.1 electromechanical tripod turnstile. Overall view: 1 turnstile housing; 2 ח barrier arm; 3 M8 bolt for barrier arm fastening; 4 ח plastic plug; 5 remote control panel / wireless remote control kit / ACS controller; 6 ח RC / wireless remote control /ACS controller cable; 7 turnstile power supply; 8 - turnstile power cable; 9 ח AC power cable; 10 mechanical release key; 11 ח mechanical lock; 12 hub; 13 ח rotation mechanism; 14 cover with LED indication display; 15 ח PFG IR 10-15 anchor bolt. 5.2.3 The RC/wireless remote control/ACS controller (5) and the...

Open the catalog to page 6
TTR-04.1 Operation manual - 7

TTR-04.1 Electromechanical Tripod Turnstile e o o o B O O NC C NO NC C NO (Z) (Z) (Z) (Z) (Z) (Z) © □ © □ © □ © © □ Detector □ Ready □ PASS B □ PASS A □ Alarm □ CLB. 100.00 e XT1.H- O o o □ □ □ □ O o o XT4 o o o Light A □ht B 3<D o o o o o o o o o e e |0?D|0|D?n| 17 IlslJl nnnnnnn aan _ □ □ u □ □□□ eu m cm uuuuuuu nnnnnnn o o o XT2 UUUUUUU e □ e XT3 e e □ Fig. 2. Control Logic Board (CLB) If the turnstile orientation relatively to the operator's terminal is not standard (e.g. the terminal is placed at the backside of the turnstile housing), the RC orientation towards the turnstile can be...

Open the catalog to page 7
TTR-04.1 Operation manual - 8

Operation manual TTR-04.1 Tripod Turnstile A6 A7 A1' >-XT4 Light A Control 1= X1-» ZLZ )-X1 ^X2-> >-X1 CM Green 1 NO 2 C 3 NC RI A RedHH8>- X2-< <-X1 1 1 A8 IM A11 A2* 1 NO 2 C 3 NC Control Logic Board Green 1-4 (S״-RI B Red 1 Black(Grey) RC In XT1.L-< Common 2 White A3* GND * Unlock A 4 Stop 5 Unlock B □ Led A 7 Led Stop 8 LedB Left button 3 Blue 4 Green 5 Yellow | 6 Orange lr 7 Red 1 |F 2 3 4 1 Black 2 White | 3 Blue | 4 Yellow If Red lr RIPS Stop button Right button A4* -XT1.H Out Left indicator Stop indicator 1 GND +12 V 3 Alarm 1 4 Alarm 2 Common 6 PassA / Pass B Ready Fl Det Out Right...

Open the catalog to page 8
TTR-04.1 Operation manual - 11

TTR-04.1 Electromechanical Tripod Turnstile 5.5 Control modes 5.5.1 There are two modes of the turnstile control - a pulse mode and a potential mode. They determine available operating modes of the turnstile (Table 1and Table 2). 5.5.2 The control mode is set by the jumper on the J1 connector (the J1 connector location is shown on Fig. 2 and on a label located on the inner surface of turnstile cover (14)): the jumper is fixed the pulse control mode, the jumper is not fixed ח the potential control mode. The jumper is fixed at the factory before the delivery. 5.5.3 Control over the turnstile...

Open the catalog to page 11
TTR-04.1 Operation manual - 12

Opration manual 5.5.5 The potential control mode is intended for the turnstile opration from the ACS controller, outputs of which support the potential control mode (for example, a lock controller). Standard control inputs: "Unlock A" and "Unlock B" Special control inputs: "Stop" and "Fire Alarm". See Table 2 for the turnstile operating modes at this control mode. The algorithm of control signals at this mode is stipulated in Appendix B. The minimum input signal duration, when the operating mode can be changed, should be 100msec. The passage waiting time is equal to the low-level signal...

Open the catalog to page 12
TTR-04.1 Operation manual - 13

TTR-04.1 Electromechanical Tripod Turnstile 5.8 Opration with ACS controller 5.8.1 In the pulse control mode control over the turnstile with an ACS controller is similar to that with the Rc. 5.8.2 In the potential control mode control over the turnstile with an ACS controller is similar to that with the RC and lies in forming of low-level signal on the contacts "Unlock A", "Stop" and "Unlock B" relatively to the contact "GND". 5.8.3 The difference of the operation logic in the potential control mode and in the pulse control mode (as per Clause 5.6.2): the command described in Clause 5.6.2.5...

Open the catalog to page 13
TTR-04.1 Operation manual - 15

TTR-04.1 Electromechanical Tripod Turnstile 5.11.2 In case of unauthorized access the "Ready" signal is formed as follows: at 8° arm rotation one of the optical sensors (Fig. 11) responds and the output contacts "Ready" and "Common" get broken (the beginning of the signal). When the barrier arms reset to home position, the both optical sensors become passive and the output contacts "Ready" and "Common" get closed (the finish of the signal). 5.11.3 In case of delay of an authorized passage for more than 30 sec. the signal "Ready" is formed as follows: if within 30 seconds from the moment of...

Open the catalog to page 15
TTR-04.1 Operation manual - 16

Operation manual to level the foundation so that the anchoring points of the turnstile lie in the same plane; Օ to apply reinforcing elements (300x300x300mm) for installation on less steady foundation (frame foundation, for example); to mark the mounting holes according to Fig. 9; Օ to control the vertical position of the turnstile during installation; to arrange additional emergency exit; Օ when creating the passage area through the turnstile take into account that the resetting device operates as follows: - at the barrier arm turning at the angle of more than 60° the reset is effected...

Open the catalog to page 16
TTR-04.1 Operation manual - 17

TTR-04.1 Electromechanical Tripod Turnstile 8.3 Cable length The maximum allowed length of the remote control panel/wireless remote control/ACS controller cable is no more than 50m. The maximum allowed length of the turnstile power cable depends on the cable cross-section and should be: - for cable with 0.2mm2 cross-section (AWG 24) no more than 10m; - for cable with 0.75mm2 cross - section (AWG 18) ח no more than 25m; - for cable with 1.5mm2 cross - section (AWG 16) no more than 50m. 8.4 Installation procedure Note! The manufacturer shall not be liable for any damage caused as the result...

Open the catalog to page 17
TTR-04.1 Operation manual - 18

Opration manual 8.4.3 Insert sleeves for anchor bolts into the holes so that they do not stick out above the floor surface. Set up the housing and fix it with the M10 bolts using S17 socket wrench. Put the plastic plugs (4) in their places. Note! If you lay out cables under the floor surface, make an electric raceway to the cables laying zone of the turnstile housing (option 1 or 2 in Fig.9). Fix the housing after laying the cables in the electric raceway and inside the turnstile housing. 8.4.4 Remove the cover with light indication display (14) in the following way: - unscrew the central...

Open the catalog to page 18