1. Catalogs
  2. Pepperl+Fuchs SE
  3. Termination Board FC-GPCS-RIO16-PF

Termination Board FC-GPCS-RIO16-PF
1 /5Pages

Termination Board FC-GPCS-RIO16-PF

Termination Board FC-GPCS-RIO16-PF
1 /5Pages

Catalog excerpts

Termination Board FC-GPCS-RIO16-PF-1

Termination BoardFC-GPCS-RIO16-PF ■ System board for Honeywell Safety Manager ■ Recommended system cable: CaB-HON-**-S37C32-MX-01000 ■ Hazardous area: pluggable screw terminals, blue ■ Non-hazardous area: Sub-D connector (male), 37-pin us Release date: 2025-08-12 Date of issue: 2025-08-12 Filename: 232114_eng.pdf Function The function of the termination board and the connector pin assignment are exactly fitted to the requirements of the Honeywell system. The signal is output to the safety instrumented system via the system connector. Information about a missing supply voltage of the isolated barriers is available for the system as a volt-free contact. It is possible to transfer a fault signal to channel 1 of the card via the loop-in function. The termination board has a robust plastic housing. The termination board is mounted in the switch cabinet on a 35 mm DIN mounting rail according to EN 60175. • Termination board 1 and cable 1: channel 1 to 16 • Termination board 2 and cable 2: channel 17 to 32 Nominal voltage 24 V DC , in consideration of rated voltage of used isolators Voltage drop 0.9 V , voltage drop across the series diode on the termination board must be Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com [email protected] [email protected]

 Open the catalog to page 1
Termination Board FC-GPCS-RIO16-PF-2

FC-GPCS-RIO16-PF Release date: 2025-08-12 Date of issue: 2025-08-12 Filename: 232114_eng.pdf Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com

 Open the catalog to page 2
Termination Board FC-GPCS-RIO16-PF-3

Termination Board Release date: 2025-08-12 Date of issue: 2025-08-12 Filename: 232114_eng.pdf Typical Circuit Module Switch Setting Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com

 Open the catalog to page 3
Termination Board FC-GPCS-RIO16-PF-4

Termination Board Release date: 2025-08-12 Date of issue: 2025-08-12 Filename: 232114_eng.pdf Refer to the documentation of the isolated barrier for exact connection assignment for connection to field side and control side. Observe the pinout configuration. For information refer to corresponding pin-out table on www.pepperl-fuchs.com. Refer to "General Notes Relating to Pepperl+Fuchs Product Information". www.pepperl-fuchs.com [email protected] [email protected] [email protected] 4

 Open the catalog to page 4
Termination Board FC-GPCS-RIO16-PF-5

Termination Board ApplicationTypical circuit Module switch settings Type (AI) Release date: 2025-08-12 Date of issue: 2025-08-12 Filename: 232114_eng.pdf For exact pin assignment for connection to field side and control side, see the documentation of the isolated barrier. The pin-out configuration has to be observed. For information see corresponding pin-out table on www.pepperl-fuchs.com. Refer to "General Notes Relating to Pepperl+Fuchs Product Information". www.pepperl-fuchs.com [email protected] [email protected] [email protected] 5

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.