4-channel Inputs Ex ia Installation in suitable enclosures in Zone 1 Module can be exchanged under voltage (hot swap) Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc. < Simulation mode for service operations (forcing) < Line fault detection (LFD) < Permanently self-monitoring Function The RTD converter accepts 2-, 3-, 4-wire RTD signals (Pt100 ... Pt1000) and slide-wire sensors from the field. Ni100 through Ni1000 can also be connected. Open and short-circuit line faults are detected. The intrinsically safe inputs are galvanically isolated from the bus and the power supply. Release date: 2025-03-03 Date of issue: 2025-03-03 Filename: 276331_eng.pdf Technical Data Slots Occupied slots Supply Connection Rated voltage 12 V DC , only in connection with the power supplies FB92** Power dissipation Power consumption manufacturer-specific bus to standard com unit temperature input Number of channels Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 www.pepperl-fuchs.com [email protected] [email protected]
Open the catalog to page 1Measuring range Slide-wire sensor Measuring current Smallest span Linearity error Conversion time Pt100 (18-390 Q) (500 Q incl. line resistance) Pt200 (37-780 Q) Release date: 2025-03-03 Date of issue: 2025-03-03 Filename: 276331_eng.pdf Busy after download Lead resistance Line fault detection Short-circuit Open-circuit Transfer characteristics Influence of ambient temperature Directive conformity Electromagnetic compatibility Directive 2014/30/EU Electromagnetic compatibility Degree of protection Environmental test Shock resistance Vibration resistance Damaging gas Relative humidity Ambient...
Open the catalog to page 2Degree of protection IP20 (module) , a separate housing is required acc. to the system description Connection removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) Data for application in connection with hazardous areas EU-type examination certificate Marking Power Po 123 mW (linear characteristic) Galvanic isolation Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V Directive conformity ATEX approval IECEx approval IECEx certificate IECEx marking...
Open the catalog to page 3Assembly Front view Sockets for removable plugs blue (accessory) Release date: 2025-03-03 Date of issue: 2025-03-03 Filename: 276331_eng.pdf Refer to "General Notes Relating to Pepperl+Fuchs Product Information". www.pepperl-fuchs.com [email protected] [email protected] [email protected] 4
Open the catalog to page 43 Pages
2 Pages
3 Pages
3 Pages
3 Pages