Interface Technology Remote I/O Systems Fieldbus Infrastructure - 1

Quick Select Product Guide Process Interfaces Interface Technology Remote I/O Systems Fieldbus Infrastructure

Open the catalog to page 1
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 2

Quick Select Product Guide: Use, Purpose, and Target Group The Quick Select Product Guide for interface technology, FieldConnex®, and remote I/O connection technologies is designed for experienced users such as technicians and engineers. This guide will help you select the right technology and systems when designing plants. Selection tables with specific product features will help you find the right solution or component quickly and reliably. You can find more detailed system descriptions as well as a basic explanation of explosion protection and the different technologies available (signal...

Open the catalog to page 2
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 3

The courage to take commercial risks, an inquiring mind, and the belief in one’s own abilities - these are the assets on which Walter Pepperl and Ludwig Fuchs established a small radio workshop in the German city of Mannheim back in 1945. A few years later, they demonstrated their credentials by inventing the proximity sensor. This marked the start of a success story that has been shaped as much by close customer relationships as by pioneering technology and automation technology processes. Then as now, our focus is directed squarely on the individual requirements of each customer. Whether...

Open the catalog to page 3
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 4

The Right Technology for Every Requirement Choosing the right connection technology is a fundamental part of plant design. Interface technology is a proven, easyto-manage method of assigning each signal to a terminal. Point-to-point wiring allows the device to be connected directly to the I/O card and used in the control cabinet. A wide range of modules and systems offers the right solution for every application.

Open the catalog to page 4
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 5

Remote I/O systems combine conventional field technology with modern bus technology. This means that when modernizing and expanding plants, the existing field technology can be connected with the control system over the remote I/O system via a fieldbus. FieldConnex® facilitates the connection of high-level bus systems to digital communication in the field. Wherever processes require high performance and maximum transparency, digital communication enables sophisticated, intelligent diagnostics and remote configuration. Deviations in the quality of the data and the installation itself will be...

Open the catalog to page 5
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 6

Enclosure Solutions

Open the catalog to page 6
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 7

Enclosure Solutions Enclosure Solutions Interface Technology The entire range of interface products from Pepperl+Fuchs can be integrated into customer-specific cabinet and enclosure solutions. This reduces commissioning time and improves return on investment. Remote I/O Systems Pepperl+Fuchs offers standard enclosure solutions for remote I/O that are designed for the most demanding applications in explosion-hazardous areas. The surrounding enclosures are already equipped with backplanes with simple connections to I/O modules. These solutions are available in corrosion- and impact-resistant...

Open the catalog to page 7
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 8

Interface Technology Interface Technology: Isolated Barriers, Signal Conditioners, and Zener Barriers Interface technology ensures reliable signal transmission between the control level and field devices. It includes products for explosion and surge protection, galvanic isolation between the field and control panel, and digital communication based on the HART protocol.

Open the catalog to page 8
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 9

Interface Technology K-System Isolated Barriers and Signal Conditioners The K-System offers the broadest product portfolio of its kind, has the right solution for every requirement in the process industry, and is designed for a mixture of applications involving both Ex modules and non-Ex modules. The modules are snapped onto a DIN mounting rail. They can be energized via terminals and via the Power Rail, which also transmits a collective error message. K-System isolators offer removable terminal blocks for wiring on the control and field sides, and control elements on the front of the...

Open the catalog to page 9
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 10

Interface Technology Interface Technology K-System Isolated Barriers Digital input signals Switch amplifiers Interval relay Time function Reset function Line fault transparency Splitter function Reversible mode of operation Fault indication output Line fault detection Relay and Voltage output volt-free contact NAMUR sensor

Open the catalog to page 10
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 11

Synchronization monitoring Slip monitoring SIL 2 Installation in Zone 2 Installation in Div. 2 ■ Rotation direction monitoring ■ ■ Line fault detection ■ Pulse divider Trip relay Frequency conversion Fault indication output Rotation speed monitoring Housing width volt-free contact NAMUR sensor Housing width Time delay Conformal coating Min./max. control Line fault detection Conductivity measurement Fault indication output

Open the catalog to page 11
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 12

Interface Technology Digital output signals Solenoid drivers Loop powered Logic input Housing width Loop powered Test pulse immunity Conformal coating Line fault detection Fault indication output Relay modules Model Number visual alarm audible alarm Field device supply Output current

Open the catalog to page 12
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 13

SIL 2 Installation in Zone 2 Installation in Div. 2 ■ ■ ■ Fault indication output For long field lines Line fault detection For higher field voltages Splitter function Test sockets Current source

Open the catalog to page 13
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 14

SIL 2 Installation in Zone 2 Installation in Div. 2 Loop powered Line fault detection Reverse polarity protection Splitter function HART communication HART communication Trip relay To the field / To the control system Transmission Direction active sources Transmitter supply Field Side Model Number Fire alarm

Open the catalog to page 14
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 15

Interface Technology Signal converters for current and voltage Signal converters for resistors and potentiometers Housing width

Open the catalog to page 15
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 16

Loop powered Splitter function Line fault detection Internal cold junction compensation Programmable high/low alarm Line fault detection Trip relay Resistance thermometer Current / voltage Resistance thermometer

Open the catalog to page 16
Interface Technology Remote I/O Systems Fieldbus Infrastructure - 17

Interface Technology Analog output signals Current drivers Reverse polarity protection Fire alarm Loop powered For long field lines Test sockets Fault indication output HART communication To the field / To the control system Transmission Direction

Open the catalog to page 17

All Pepperl+Fuchs SE catalogs and technical brochures

  1. VariKont L

    4 Pages

  2. UMB800

    8 Pages

  3. WirelessHART®

    16 Pages

  4. THE BARRIER