RDX6LE-40
2Pages

{{requestButtons}}

Catalog excerpts

RDX6LE-40 - 1

Residual current operated circuit breaker with over-current protection Application RDX6LE-40 Residual circuit breaker,be mainly applied to the circuit of AC50Hz(60Hz), rated working voltage 220V or 380V, rated current up to 63A to protect human against the electric leakage indirectly, and to prevent the fire result from the ground fault due to the damaged insulation of the equipment.And it also has the overload protection for the building circuit or other similar circuit. And it hase the powerful auxiliary function module, like auxiliary contact, alarm indication contact, shunt and underlvoltage release, remote release control. This prodution conforms the standard of GB16817.1 and IEC61009-1. Frame size rated current (A) Electronic residual current circuit breaker Design No. Plastic shell circuit breaker Company Code. Normal working condition and Installation environment 3.1 Altitudeof Installation location no more than 2000m. 3.2 The relative humidity: no more than 50%, when Temperature is +40 ºC. The product can withstand the higher humidity under lower temperature, for instance, when temperature at +20ºC, the product can withstand 90% relative humidity. The condensation that happened because of temperature changes should be taken care in special measurements 3.3 Class of pollution : 2 Class 3.4 Electronicmagnetic environment: B 3.5 Installation condition: I, II type 3.6 Installation method: TH35-7.5, distribution box or cabinet. Main technical parameter 4.1 Poles: 1P+N 4.2 Instanteous tripping type: C type 4.3 Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A. 4.4 Rated Residual operating current: 30mA, 100mA, 300mA 4.5 Rated voltage: 220V(230V) 4.6 Residual operating current: 30mA, 100mA, 300mA 4.7 MCB's overload current tripping characteristics follows the Table 1 under the normal install conditions and basis environment temperature(30~35°C). www.chinapeople.com Email: simon@chinapeople.com

Open the catalog to page 1
RDX6LE-40 - 2

RCBO RDX6LE-40 Residual current operated circuit breaker with over-current protection 4.6 Main technical parameter see table 1,2 Rated current (In) All value All value <32A > 32A All value All value Time limit t<lh t<lh Is < t < 60s Is < t < 120s t^O.ls t < 0.1s Expected result Not tripping Tripping Tripping Not tripping Tripping Initial state Cold state Right after Test No.1 Cold state Cold state Cold state Release type Rated current (In) Rated short-circuit Rated residual operated current Rated residual non-operated current www.chinapeople.com Email: simon@chinapeople.com

Open the catalog to page 2

All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures

  1. DZ47-63

    2 Pages

  2. LXP1

    2 Pages

  3. RDQ1

    6 Pages

  4. RDX30LE-32

    2 Pages