Residual current operated circuit breaker with over-current protection Application RDX65LE-63 series earthleakage circuit breaker, maily applied to circuit of AC 50Hz, Rated voltage 230V(400V), rated current up to 63A, for protecting circuit against the overload, short-circuit and electric leakage to making, breaking and transfering infrequent. And it also has the advantages of high breaking capacity, good accessory adapatability,small volume, light weight,beatiful outlook and easy using. This product conforms to the standard of GB16917.1. N: with the unbreaking neutral line Poles Frame size rated current (A) Electronic residual current circuit breaker Design No. Plastic shell circuit breaker Company Code Normal working condition and Installation environment 3.1 Temperature: no higher than +40 ºC , and no lower than -5 ºC, and the average temperture no higher than +35 ºC. 3.2 Altitudeof Installation location no more than 2000m. 3.3 The relative humidity: no more than 50%, when Temperature is +40 ºC. The product can withstand the higher humidity under lower temperature, for instance, when temperature at +20ºC, the product can withstand 90% relative humidity. The condensation that happened because of temperature changes should be taken care in special measurements 3.4 Class of pollution : 2 Class 3.5 Electronicmagnetic environment: B 3.6 The megnetic field of the installation place should not bigger than the earth magnetic field in any direction. 3.7 Installation method: TH35-7.5, distribution box or cabinet. 3.8 Installation: The angle between the vertical plane and installation plane no more than 5. 3.9 Installation condition: the installation location should have no heavy impact and vibration, and in the medium that no danger (explosion). 3.10 Installation type : 2 ,3 Class Main technical parameter 4.1 Specification and technical parameter(see Table 1) 4.2 Rated residual operated current: 30mA 4.3 Rated residual non-operated current: 15mA 4.4 Rated residual breaking and making capacity: 500A 4.5 Leakage operated time: t no more than 0.1s. 4.6 Impulse tolerance voltage: Uimp=4kV 4.7 Delay operated characteristic: see Table 2 4.8 Instantaneous operated characteristic: see Table 3 www.chinapeople.com Email: simon@chinapeople.c
Open the catalog to page 1RCBO RDX65LE-63 Residual current operated circuit breaker with over-current protection Rated current(A) Rated short-cir Voltage (V) cui'obrciacu^ capacity breaking capacity (A) COS$ 1P + N,2P 230 6000(4~40A) 0.65-0.7 Tripping type Testing current (A) Initial state cold state heat state (After 1.13In test) cold state Limit time t£lh t< lh ls<t<60s ls<t<120s Table 2 Excepting result Nor-tripping Tripping Tripping ► Overall and installation dimensions Installation method: TH35-7.5 Din rail www.chinapeople.com Email: simon@chinapeople.com
Open the catalog to page 2All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures
-
DZ47-63
2 Pages
-
LXP1
2 Pages
-
RDQ1
6 Pages
-
WL Series Travel switch
2 Pages
-
RDLX18 Series Travel switch
3 Pages
-
RDD6 series indicator lamp
2 Pages
-
RDJR6 series soft-starter
7 Pages
-
RDI67 series inverter
3 Pages
-
RDR67 Series Relay
6 Pages
-
JRS2 Series Thermal Relay
5 Pages
-
RDC67 series AC contactor
3 Pages
-
CJX5 Series AC Contactor
3 Pages
-
RDC6 Series AC Contactor
4 Pages
-
CJX1 Series AC Contactor
4 Pages
-
RDSP6 serie surge arrester
2 Pages
-
RDB67LE-63 series RCBO
3 Pages
-
DZ47LE series RCBO
2 Pages
-
RDL67-63 series RCCB
2 Pages
-
RDL63E-63 series RCCB
2 Pages
-
RDX30LE-32
2 Pages
-
RDX6LE-40
2 Pages
-
RDX6LE-63 series RCBO
2 Pages
-
RDB5-63 series MCB
1 Pages
-
RDX6-40 series MCB
2 Pages
-
RDB2-125S series MCB
2 Pages
-
RDX6-63DC series MCB
2 Pages
-
RDX30-32 series MCB
2 Pages
-
RDX65-63 series MCB
2 Pages
-
RDB2-125 series MCB
3 Pages
-
RDB67-63 series MCB
2 Pages
-
RDX2-125 series MCB
2 Pages
-
RDX6-63 series MCB
2 Pages
-
QZB series auto-transformer
2 Pages
-
RDW2-1600 series
13 Pages