RDX6-63DC series MCB
2Pages

{{requestButtons}}

Catalog excerpts

RDX6-63DC series MCB - 1

Usage and its scope of application RDX6-63/DC MCB is suitable for the DC distribution circuit of AC 50/60Hz, rated voltage up to 400V, rated current up to 63A, rated short-circuit breaking capacity does not exceed 6000A, as the use of circuit's infrequently connecting, breaking and switching, with the functions of over-load, short-circuit protection. Meanwhile, it has strong auxiliary function modules, such as auxiliary contacts, contacts with alarming indication, shunt releasing, under-voltage releasing, and remote release control etc. modules. This product confirms to GB10963.1 and IEC60898-1 standards. Model and its implication DC code Rated current (A) Design serial No. MCB Enterprise code Normal operating condition and installation condition 3.1 Ambient temperature: -5ÿ~+40ÿ, average temperature within 24h does not exceed +35ÿ; 3.2 Altitude of installation place: does not exceed 2000m; 3.3 Relative humidity does not exceed 50% when it is at highest temperature of +40ÿ, and it is allowed relatively high relative humidity when it is at relatively low temperature, for example, it reaches 90% when it is at 20ÿ. It should take measurements when there occurred condensation on the product due to the temperature variation. 3.4 Grade of pollution: 2 3.5 Installation condition: it should be installed at the places of without obvious impact and vibration as well as the medium without danger (explosion). 3.6 Installation mode: adopts TH35-7.5 installation rail 3.7 Installation category: II, III Classification 4.1 Number of pole: 1P, 2P 4.2 Releasing characteristics: C type 4.3 Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63A 4.4 Rated operating voltage: 220V/440V

Open the catalog to page 1
RDX6-63DC series MCB - 2

► Main technique parameter 5.1 Over-current releasing characteristics should confirm to table 1 when the circuit breaker is at normal installation condition and basic temperature of 30-35y. ► External and installation dimension External and installation dimension map of circuit breaker ► Ordering Notice It required to be noted: 1) Model and specification, for example, RDX6-63/DC MCB 2) Number of pole, for example, 2P 3) Rated current, for example, 25A 4) Releasing type, for example, C type 5) Ordering quantity, for example, 1000 pcs For example, RDX6-63/DC, 2P, C40, 1000pcs for ordering...

Open the catalog to page 2

All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures

  1. DZ47-63

    2 Pages

  2. LXP1

    2 Pages

  3. RDQ1

    6 Pages

  4. RDX30LE-32

    2 Pages

  5. RDX6LE-40

    2 Pages