Catalog excerpts
RDX6-40 Series Miniature Circuit Breaker Usage and its scope of application RDX6-40 MCB is suitable for the distribution circuit of AC 50/60Hz, rated voltage up to 400V, rated current up to 63A, rated short-circuit breaking capacity does not exceed 6000A, as the use of circuit's infrequently connecting, breaking and switching, with the functions of over-load, short-circuit protection. Meanwhile, it has strong auxiliary function modules, such as auxiliary contacts, contacts with alarming indication, shunt releasing, under-voltage releasing, and remote release control etc. modules. This product confirms to GB10963.1 and IEC60898-1 standards. Rated current (A) Design serial No. MCB Enterprise code Normal operating condition and installation condition 3.1 Ambient temperature: -5℃~+40℃, average temperature within 24h does not exceed +35℃; 3.2 Altitude of installation place: does not exceed 2000m; 3.3 Relative humidity does not exceed 50% when it is at highest temperature of +40℃, and it is allowed relatively high relative humidity when it is at relatively low temperature, for example, it reaches 90% when it is at 20℃. It should take measurements when there occurred condensation on the product due to the temperature variation. 3.4 Grade of pollution: 2 3.5 Installation condition: it should be installed at the places of without obvious impact and vibration as well as the medium without danger (explosion). 3.6 Installation mode: adopts TH35-7.5 installation rail 3.7 Installation category: II, III Classification 4.1 Number of pole: 1P+N 4.2 Releasing characteristics: C type 4.3 Rated current: 6, 10, 16, 20, 25, 32, 40A 4.4 Rated operating voltage: 230V(220V) 4.5 Over-current releasing characteristics should confirm to table 1 when the circuit breaker is at normal installation condition and basic temperature of 30-35℃.
Open the catalog to page 14.6 Main technique parameter to see table 1 and table 2 Releasing type c c c c c Rated current In All value All value <32A > 32A All value All value Setting time t< lh t< lh Is < t < 60s Is < t < 120s t<0.1s t < 0.1s Predict results Not releasing Table 1 Initial status Cool status Followed after test No. 1 Cool status Cool status Cool status Releasing type Rated current A Rate d short- circuit breaking c apacity A CO S 4> External and installation dimension Ordering Notice It required to be noted: 1) Model and specification, for example, RDX6-63 MCB 2) Number of pole, for example, 2P 3)...
Open the catalog to page 2All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures
-
DZ47-63
2 Pages
-
LXP1
2 Pages
-
RDQ1
6 Pages
-
WL Series Travel switch
2 Pages
-
RDLX18 Series Travel switch
3 Pages
-
RDD6 series indicator lamp
2 Pages
-
RDJR6 series soft-starter
7 Pages
-
RDI67 series inverter
3 Pages
-
RDR67 Series Relay
6 Pages
-
JRS2 Series Thermal Relay
5 Pages
-
RDC67 series AC contactor
3 Pages
-
CJX5 Series AC Contactor
3 Pages
-
RDC6 Series AC Contactor
4 Pages
-
CJX1 Series AC Contactor
4 Pages
-
RDSP6 serie surge arrester
2 Pages
-
RDB67LE-63 series RCBO
3 Pages
-
DZ47LE series RCBO
2 Pages
-
RDL67-63 series RCCB
2 Pages
-
RDL63E-63 series RCCB
2 Pages
-
RDX30LE-32
2 Pages
-
RDX65LE-63 series RCBO
2 Pages
-
RDX6LE-40
2 Pages
-
RDX6LE-63 series RCBO
2 Pages
-
RDB5-63 series MCB
1 Pages
-
RDB2-125S series MCB
2 Pages
-
RDX6-63DC series MCB
2 Pages
-
RDX30-32 series MCB
2 Pages
-
RDX65-63 series MCB
2 Pages
-
RDB2-125 series MCB
3 Pages
-
RDB67-63 series MCB
2 Pages
-
RDX2-125 series MCB
2 Pages
-
RDX6-63 series MCB
2 Pages
-
QZB series auto-transformer
2 Pages
-
RDW2-1600 series
13 Pages