RDX30-32 series MCB

RDX30-32 series MCB

RDX30-32 series MCB

Product catalog summary
Introduction and Application Scope
RDX30-32 Series MCB is designed for protective distribution circuits in AC systems with a frequency of 50Hz or 60Hz. It supports a rated operating voltage up to 220V (230V) and a rated current up to 32A. The device can handle short-circuit breaking capacities up to 4500A. It is suitable for infrequent circuit connections, disconnections, and switching, providing overload and short-circuit protection. The circuit breaker complies with the GB10963.1 standard.
Model and Implications
The model includes specifications such as rated current of frame size, design serial number, MCB, and enterprise code.
Operating and Installation Conditions
  • Ambient temperature: -5°C to +40°C, with a 24-hour average not exceeding +35°C.
  • Installation altitude: Maximum 2000m.
  • Atmospheric conditions: At +40°C, relative humidity should not exceed 50%. Higher humidity is permissible at lower temperatures, e.g., 90% at 20°C. Special measures are needed for condensation due to temperature variations.
  • Pollution grade: 2
  • Installation conditions: Suitable for locations without significant impact, vibration, or explosive hazards.
  • Installation category: II, III grade
Technical Specifications
  • Number of poles: 1P+N
  • Releasing type: C type
  • Rated current options: 6, 10, 16, 20, 25, 32A
  • Rated operating voltage: 220V (230V)
  • Over-current releasing characteristics: Confirmed under normal installation conditions and reference temperature (30~35°C).
Main Technical Parameters
Refer to tables 1 and 2 for detailed technical parameters, including releasing type, rated current, and short-circuit breaking capacity.
External and Installation Dimensions
Refer to map 4 for the external and installation dimensions of the circuit breaker.
Ordering Notice
When ordering, specify the product model, rated current, number of poles, releasing type, and quantity required. Example: RDX30-32 C32 1P+N, 2000 pcs.
See more

Catalog excerpts

RDX30-32 series MCB-1

Usage and its scope of application RDX30-32 MCB is suitable for the protective distribution circuit of AC 50Hz (or 60Hz), rated operating voltage up to 220V (230V), rated current up to 32A, rated short-circuit breaking capacity does not exceed 4500A, as the use of circuit's infrequently connecting, breaking and switching, with the functions of over-load and short-circuit protection. Circuit breaker confirms to GB10963.1 standard. Model and its implication Rated current of frame size (A) Design serial No. MCB Enterprise code Normal operating condition and installation condition 3.1Ambient temperature: -5ÿ~+40ÿ; Average value in 24h does not exceed +35ÿ. 3.2 Altitude height of Installation places does not exceed 2000m. 3.3 Condition of atmosphere When it is the highest temperature +40ÿ, the relative humidity does not exceed 50%, and it allows a certain high relative humidity when it is at relatively low temperature. For example, it reaches 90% when 20ÿ, and it should take special measurements when there occurring condensation due to the temperature variation. 3.4 Pollution grade: 2 3.5 Installation condition: Installing at the places that without obvious impact and vibration, as well as the medium without danger (explosion). 3.7 Installation category: II, III grade Main technique parameter 4.1 Number of pole: 1P+N 4.2 Releasing type: C type 4.3 Rated current: 6, 10, 16, 20, 25, 32A 4.4 Rated operating voltage: 220V(230V) 4.5 Over-current releasing characteristics: under the normal installation condition and reference temperature (30~35)ÿ, the over current releasing characteristics confirms to table 1.

 Open the catalog to page 1
RDX30-32 series MCB-2

Table 1 Predict results Initial status Not releasing Cool status Releasing SSSlW fer the test of Releasing Cool status Not releasing Cool status Releasing Cool status 4.6 Main technique parameter index to see table 1, and table 2. No. Releasing type Rated current In Testing current A Releasing time i c All value i.i3in t<ih Releasing type Rated current A Rated short-circuit breaking capacity A cos<t> External and installation dimension External dimension and installation dimension of circuit breaker to see map 4 18 ^Ordering Notice It required to be noted: product model,...

 Open the catalog to page 2

All PEOPLE ELE. APPLIANCE GROUP CO., LTD. catalogs and technical brochures

  1. DZ47-63

    2  Pages

  2. LXP1

    2  Pages

  3. RDQ1

    6  Pages

  4. RDX30LE-32

    2  Pages

  5. RDX6LE-40

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.