Usage and its scope of application RDX2-125High breaking circuit breaker is one current-limit type MCB of with over-load and short-circuit double protection. Circuit breaker is suitable for the circuit of AC 50Hz or 60Hz, rated operating voltage up to 230V/400V, rated current up to 125A, as the use of over-load, short-circuit protection of circuit, and it also can be used as infrequently connecting and breaking the electric device and lighting circuit. Circuit breaker confirms to IEC60947-2 and GB14048.2 etc. relevant standards. Normal operating condition and installation condition 3.1 Ambient temperature: -5 C ~ +40 C; Average value in 24h does not exceed +35 C. 3.2 Altitude height of Installation places does not exceed 2000m. 3.3 Condition of atmosphere When it is the highest temperature +40 C, the relative humidity does not exceed 50%, and it allows a certain high relative humidity when it is at relatively low temperature. For example, it reaches 90% when 20 C, and it should take special measurements when there occurring condensation due to the temperature variation. 3.5 Installation condition: Installing at the places that without obvious impact and vibration, as well as the medium without danger (explosion). 3.6 Installation mode: installed by TH35-7.5 installation rail. It usually adopts the vertical installation, and the gradient between the installation side and the vertical side does not exceed ±5°. 3.7 Installation category: II, III grade Product classification 4.1 Number of pole: IP, 2P, 3P, 4P 4.2 Rated current: 63, 80, 100, 125A 4.3 Rated operating voltage: 230V/400V www.peopIeelectric.com simon@chinapeople.com
Open the catalog to page 1RDB2-125 Series MCB Characteristics of structure 5.1 Circuit breaker with high current-limit capacity, thereby largely limit the damage caused by the short-circuit, its characteristics of current-limit to see map 1 5.2Main parameter of circuit breaker to see table 1, over-current protective characteristics to see table 2 Table 1 ,, , . ,, , , , ,, Rated short-circuit breaking Number of pole Rated voltage Ue (V) capacity(kA) Mechanical life (times) 20000 Testing current name Setting not-releasing current Setting releasing current T<lh not releasing T<2h not...
Open the catalog to page 2All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures
-
DZ47-63
2 Pages
-
LXP1
2 Pages
-
RDQ1
6 Pages
-
WL Series Travel switch
2 Pages
-
RDLX18 Series Travel switch
3 Pages
-
RDD6 series indicator lamp
2 Pages
-
RDJR6 series soft-starter
7 Pages
-
RDI67 series inverter
3 Pages
-
RDR67 Series Relay
6 Pages
-
JRS2 Series Thermal Relay
5 Pages
-
RDC67 series AC contactor
3 Pages
-
CJX5 Series AC Contactor
3 Pages
-
RDC6 Series AC Contactor
4 Pages
-
CJX1 Series AC Contactor
4 Pages
-
RDSP6 serie surge arrester
2 Pages
-
RDB67LE-63 series RCBO
3 Pages
-
DZ47LE series RCBO
2 Pages
-
RDL67-63 series RCCB
2 Pages
-
RDL63E-63 series RCCB
2 Pages
-
RDX30LE-32
2 Pages
-
RDX65LE-63 series RCBO
2 Pages
-
RDX6LE-40
2 Pages
-
RDX6LE-63 series RCBO
2 Pages
-
RDB5-63 series MCB
1 Pages
-
RDX6-40 series MCB
2 Pages
-
RDB2-125S series MCB
2 Pages
-
RDX6-63DC series MCB
2 Pages
-
RDX30-32 series MCB
2 Pages
-
RDX65-63 series MCB
2 Pages
-
RDB2-125 series MCB
3 Pages
-
RDB67-63 series MCB
2 Pages
-
RDX6-63 series MCB
2 Pages
-
QZB series auto-transformer
2 Pages
-
RDW2-1600 series
13 Pages