series Intelligent type universal circuit breaker Appliance RDW1-2000~6300 air circuit breaker, applied to power distribution network of AC50Hz,rated operational voltage up to 690V,Rated current from 400A to 6300A. It is mainly used to distribute powerand protect the circuit and equipments against damages of overload, short-circuit,undervoltage and ground fault. And it has Intelligent protection functions, provides accurated selective protection,improves power-supply reliability to aviod unneccessary power interruption. And it also has open type communication port,can realize remote control function and satisfy the requirments of control center and Automatic system. This production without Intelligent controller and senor has insulation function, the sign is . This protection conforms to the standard of GB14048.2 and IEC60947-2. Poles Controller type Frame size rated current C for drawout-type, non for fited-type Design code Air circuit breaker Company code 2.1 Release type Intelligent controller, Undervoltage instantaneous(or delay)release, Shunt release. 2.2 Intelligent controller function a) Intelligent control: H type(for Communication), M type(for Normal), L type(for economic) b) It has Overload long-time delay inverse time-limit, short-time delay inverse time-limit, constant time-limit, Instantaneous tripping function. The protection characteristic can be constituted to meet curtomers owned requirements. c) Single phase ground fault protection function d) Indication function:Setting current indication, Action indication, Voltage of each line indication e) Alarm indication: overload alarm f) self inspection function: over heat self-inspection, micro-computer inspection g)Testing function: test action characteristic of controller Normal operation conditon and installation condition 3.1 Temperature: no more than +40C, no less than -5C,and average day temperature no more than +35C. If customer requires condition of higher than +40C,or lower than -25C, it should be consulted with manufacture. 3.2 Installation location atitude no more than 2000m.
Open the catalog to page 13.3 Humidity: when the temperature at +40°C, it no more 50%. The higher humidity is accepted at the lower temperature. The average humidity of month should no more than 90%,and the average temperature of month should not lower than +25°C. The condensetion should be taken care when the humidity chanage. 3.5 Using type:B type 3.6 Pollution type: 3 level 3.7 Installation type: Type of circuit breaker main circuit, under-voltage release, primary coil of power transformer is Installation IV; type of Auxiliary circuit and control circuit installation is III. ^ Technical data and performance 4.1...
Open the catalog to page 24.3.3 Long-time delay overcurrent protection inverse time-lag characteristic , action time see Table 4, time error is ±15%. Note: t -setting time of longtime delay 1.5I 1, T -action time of longtime delay action time. 4.3.4 short-time delay overcurrent protection characteristic This protection is constant time-lag, if it requires the low multiply is inverse time-lag, the characteristic following: I2Ts=(8Ir1)2ts , ts is normal delay setting time; when overload current > 8Ir1, it would transfer to inverse time-lag automatically, see Table 5, and time-error is ±15%. Table 5 Delay...
Open the catalog to page 3Fig 1 overload release protection feature Fig 2 Ground fault protection feature www.peopleelectric.com simon@chinapeople.com
Open the catalog to page 4Fig 3 Loading Monitor function Fig 4 Loading Monitor function
Open the catalog to page 5ACB RDW1-2000-6300 series Intelligent type universal circuit breaker 4.5 H type intelligent release In addition to having all M type's function, it also has the RS485 standard communication port (standard configuration is Modbus communication),it can half-double or full-double communication, the regional system of main sub struture can be composed of communication port, it uses 1~2 computer as main station and uses several intelligent circuit breaker or other communication component as sub-station, system network structure see following Fig. According to circuit breaker unit, system can...
Open the catalog to page 6series Intelligent type universal circuit breaker 5.2 Soft interlock(horizon, vertical both can use, and applied to adjacent cabinets or at one cabinet) operation mode Fig 6 (B)Steel wire rope interlock 5.3 Ground fault protection mode Two protection type, 1. imbalance type(T), controller would provide protection according to current vector sum of three phase and neutral line. According to poles,it also has 3 type, 3PT,4PT,(3P+N)T, as following figure(a, b, c) correspondly. 2. Earthleakafe current type(W), controller take signal of a additional current transformer between Main power's...
Open the catalog to page 7ACB RDW1-2000-6300 series Intelligent type universal circuit breaker Circuit breaker Terminals has 47 totally.(55 for special production), connection simple for customer conveninent connecting, connection diagram see Table 8, the Terminals Number and external accessory see attached list. Note: 1. For aviodin the damage of shunt release and energy release,1 sets NO contact(Shunt) and 1 sets NC contact (energy release) in the production had been connected as default setting. Auxiliaty switch is 4 sets of transfer contact(standard setting). 2. If F,X,M controller power voltage is different, it...
Open the catalog to page 8ACB RDW1-2000-6300 series Intelligent type universal circuit breaker auxiliary power input port(For AC and DC both) Fault tripping contact output port, 4 is common port, capacity is AC380V, 16A circuit breaker state auxiliary contact output port, capacity AC380V, 16A_ Communication port extanted line 2M type is load monitor 1 output 2M type is load monitor 2 output 2H type is remote breaking(2M is pre-alarm)signal output break button(customer own) emergency breaking button(customer own) make button(customer own) auxiliary contact shunt contact limited switch #18, #19 2H type is remote...
Open the catalog to page 9Fig 8.3 5 sets of transfer contact model(special) Fig 8.4 3 sets NO and 3 sets NC(special) Fig 8.5 4 sets NO and 4 sets NC(special) Fig 8.6 5 sets NO and 5 sets NC(special) Fig 8.7 6 sets NO and 2 sets NC(special) Fig 8.8 2 sets NO and 6 sets NC(special) www.peopleelectric.com simon@chinapeople.com
Open the catalog to page 10All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures
-
DZ47-63
2 Pages
-
LXP1
2 Pages
-
RDQ1
6 Pages
-
WL Series Travel switch
2 Pages
-
RDLX18 Series Travel switch
3 Pages
-
RDD6 series indicator lamp
2 Pages
-
RDJR6 series soft-starter
7 Pages
-
RDI67 series inverter
3 Pages
-
RDR67 Series Relay
6 Pages
-
JRS2 Series Thermal Relay
5 Pages
-
RDC67 series AC contactor
3 Pages
-
CJX5 Series AC Contactor
3 Pages
-
RDC6 Series AC Contactor
4 Pages
-
CJX1 Series AC Contactor
4 Pages
-
RDSP6 serie surge arrester
2 Pages
-
RDB67LE-63 series RCBO
3 Pages
-
DZ47LE series RCBO
2 Pages
-
RDL67-63 series RCCB
2 Pages
-
RDL63E-63 series RCCB
2 Pages
-
RDX30LE-32
2 Pages
-
RDX65LE-63 series RCBO
2 Pages
-
RDX6LE-40
2 Pages
-
RDX6LE-63 series RCBO
2 Pages
-
RDB5-63 series MCB
1 Pages
-
RDX6-40 series MCB
2 Pages
-
RDB2-125S series MCB
2 Pages
-
RDX6-63DC series MCB
2 Pages
-
RDX30-32 series MCB
2 Pages
-
RDX65-63 series MCB
2 Pages
-
RDB2-125 series MCB
3 Pages
-
RDB67-63 series MCB
2 Pages
-
RDX2-125 series MCB
2 Pages
-
RDX6-63 series MCB
2 Pages
-
QZB series auto-transformer
2 Pages
-
RDW2-1600 series
13 Pages