RDW1-1000 series Intelligent type universal circuit breaker

RDW1-1000 series Intelligent type universal circuit breaker
1 / 11 PagesView full catalog

RDW1-1000 series Intelligent type universal circuit breaker

Product catalog summary
Overview: The document provides detailed information on the ACB series Intelligent type universal circuit breaker and RDW1-1000 Air Circuit Breakers, focusing on their specifications, protection features, installation guidelines, and available functions. These circuit breakers are designed for power distribution networks, offering protection against overload, short-circuit, under-voltage, and phase contact with ground faults, conforming to GB14048.2 and IEC60947-2 standards.
Specifications: The ACB series is suitable for AC50Hz networks with rated voltages of 400V (or 380V) and currents from 200A to 1000A. Key specifications include a rated insulation voltage of 690V, operational voltage of 400V, impulse withstand voltage of 8000V, and a short-circuit breaking capacity of not less than 2.1 Icu. The installation altitude is up to 2000m, with an operating temperature range of -5ºC to +40ºC and a pollution class of 3.
Intelligent Controller Types: The document outlines three types of intelligent controllers: ST450-2L (economic type with basic functions), ST450-3M (basic type with intelligent functions), and ST450-3H (advanced type with communication port).
Protection Features: The circuit breakers offer overcurrent and ground fault protection with time-inverse characteristics, short-circuit protection with time-limit characteristics, and residual leakage current protection using external transformers.
Installation and Operation: Both fixed and drawout types are available, with a vertical tilt angle for installation not exceeding 5º. The auxiliary contact capacity is 6A with various voltage ratings.
Technical Data: The document provides details on frame size rated current (200A to 1000A) and operational voltage and power consumption for shunt release, under-voltage release, and motor operation mechanisms.
Diagrams and Tables: Various tables and figures are included, detailing performance curves, connection diagrams, and installation dimensions for both fixed and drawout types.
Functions and Features: The RDW1-1000 Air Circuit Breakers offer protection functions such as overload long-time delay, short-circuit short-time delay, short-time instantaneous, and ground or earth leakage protection. Additional features include fault recording, testing, current metering, thermal modeling, communication, charged monitoring, MCR function, and self-diagnosis.
Installation and Accessories: The document details installation types, including fixed and drawout, and specifies additional components like power modules, shunt releases, auxiliary switches, and undervoltage releases. Mechanical interlocking and phase separation options are also mentioned.
Ordering Information: Customers are advised to specify their requirements, including type, poles, rated current, and additional functions, noting that selecting additional functions may increase costs.
Notes: The document distinguishes between economic (L type), normal (M type), and advanced (H type) models, with the latter offering additional communication and position locking features. MCR functions are standard, and additional leakage protection is available for M and H types.
See more

Catalog excerpts

RDW1-1000 series Intelligent type universal circuit breaker-1

series Intelligent type universal circuit breaker Appliance RDW1-1000 air circuit breaker, applied to power distribution network of AC50Hz, Rated voltage 400V (or 380V), Rated current from 200A to 1000A. It is mainly used to distribute electric power and protect the circuit and equipments against damages of overload, short-circuit, under-voltage and phase contact with ground this kind fault. And it also be used for circuit transfering, motor starting unfrequently and protection. This production has various intelligent protection functions, provides accurated selective protection, improves power-supply reliability to aviod unneccessary power interruption. It has isolation functions, sign is " ". This production conforms to the standard of GB14048.2 and IEC60947-2. Poles Controller type Frame size rated current C for drawout-type, non for fited-type Design code Air circuit breaker Company code 2.1.1 Use type: A type for unselective type, B for selective 2.1.2 Installation type: Fited-type, draw-type 2.1.3 Transmission type: Motor type, handle type 2.1.4 Poles: 3P 4P 2.1.5 Release type: Intelligent controller, shunt release, under-voltage instantaneous release(or delay release) 2.1.6 Intelligent controller type ST450-2L for economic type(basic function) ST450-3M for basic type(basic function+Intelligent function) ST450-3H for advanced type(basic function+Intelligent function+communication port) Normal operation conditon and installation condition 3.1 Temperature: no more than +40ºC, no less than -5ºC, and average day temperature no more than +35ºC. Notice: when the temperature requirment exceed the above range, it should be consulted with Manufacture. 3.2 Atitude: Installation location altitude should no more than 2000m. 3.3 Humidity: when the temperature at +40C, it no more 50%. The higher humidity is acceptd at the lower temperature. The condensetion should be taken care when the humidity chanage.

 Open the catalog to page 1
RDW1-1000 series Intelligent type universal circuit breaker-2

3.4 Pollution class: 3 class 3.5 Installation type: Circuit breaker main circuit is IV, auxilliary circuit installation type is III, except under-voltage release coil, power-supply transformer primary coil and circuit breaker main circuit. 3.6 Using type: B type 3.7 Installation condition: circuit breaker should be installed accroding to the requirements of instruction. The vertical tilt angle should not exceed 5°. 4.1 circuit breaker rated current see Table 1. Table 1 4.5 Intelligent controller protection characteristic 4.5.1 Overcurrent release performance curve see Fig 1, ground fault protection...

 Open the catalog to page 2
RDW1-1000 series Intelligent type universal circuit breaker-3

Fig IGround fault protection curve www.peopleelectric.com [email protected]

 Open the catalog to page 3
RDW1-1000 series Intelligent type universal circuit breaker-4

4.5.4 Intelligent controller short delay overcurrent protection characteristic is time-limit characteristic, the delay time: 0.2s (L type controller),0.4s, reture time is 0.21s, the limit time error is ±10%. 4.5.5 Ground fault protection action characteristic is time limited, the performance conforms Table 5, the limit time error is 15%. 4.5.6 Characteristic curve of Circuit breaker overcurrent protection and ground fault protection see Fig 1. 5.5.4 Intelligent controller short-circuit short time delay action characteristic: Short-circuit short time delay overload protection generally is time-limited,...

 Open the catalog to page 4
RDW1-1000 series Intelligent type universal circuit breaker-5

series Intelligent type universal circuit breaker RDW1 3P circuit breaker Transformer Current transformer 3PT type Balance type ground fault protection, signal only from three phases current vector sum(3 phases not balance) Intelligent controller RDW1 4P circuit breaker Transformer Current transformer 4PT type Balance type ground fault protection, signal from vector sum of three phases current and N phase Intelligent controller RDW1 3P circuit breaker Current transformer (3P+N)T type External neutral poles transformer Intelligent controller Balance type ground fault protection, signal from vector...

 Open the catalog to page 5
RDW1-1000 series Intelligent type universal circuit breaker-6

4.6 Operational voltage and power consumption of Shunt release, under-voltage release, Motor operation mechanism, Energy release (switch on)electromagnet, Intelligent controller, see Table 9. Table 9 www.peopleelectric.com [email protected]

 Open the catalog to page 6
RDW1-1000 series Intelligent type universal circuit breaker-7

M type Intelligent release Motor Energy make storage Q-Undervoltage release 5A-Motor limit switch (Delay or Instantaneous) XT-Connecting terminal F-Shunt release -signal lamp(customer owned) X-Energy release electromagnet FU-fuse M-Energy storage motor Main circuit power Emergency Motor break brake Make Control power 5.1 circuit breaker has 40 contact, connection diagram see Fig 4. #41,42-auxiliary power output port for AC,DC #43,44,45-fault tripping contact output port, 4 is common port #46,47,48,49-circuit breaker state auxiliary contact output port #79,80- external transformer input terminal...

 Open the catalog to page 7
RDW1-1000 series Intelligent type universal circuit breaker-8

www.peopleelectric.com 5A-Motor limit switch XT-Connecting terminal -signal lamp(customer owned) FU-fuse(customer owned) Energy storage Motor Energy make storage Control power #41,42-auxiliary power output port #43,44,45-fault tripping contact output port, 44 is common port #46,47- Remote breaking contact output #48,49-Remote making contact output #50,51-RS485 communication port #73,74-Overload pre-alarming #75,76-Fault tripping alarm #77,78,79,80-voltage measuring signal: is UA,UB,UC,UN correspondingly, And it should be connected correctily, if not, the control would not work normally. Auxiliary...

 Open the catalog to page 8
RDW1-1000 series Intelligent type universal circuit breaker-9

series Intelligent type universal circuit breaker Installation and overall dimension 6.1 Fixed type circuit installation dimension and overall dimension,see Table 6. 245(3 pole X Installation centre hole) 275(3 poles) 315(4 poles X Installation centre hole) Rated current In: 200A~400A(A busbar dimension) Rated current In: 630A~1000A(A busbar dimension) Rated current(A) Fig 6 RDW1-200A~1000A Fixed type circuit breaker

 Open the catalog to page 9
RDW1-1000 series Intelligent type universal circuit breaker-10

series Intelligent type universal circuit breaker 6.2 Drawout type circuit breaker Installation and Overall dimension, see Fig 7. 194(3Pole)(Installation centre hole) 284(3Pole) 264(4Pole)(Installation centre hole) Rated current In: 200A~400A(A busbar dimension) Rated current In: 630A~1000A(A busbar dimension) Rated current(A) 3Pole 4Pole Fig 6 RDW1-200A~1000A Drawout type circuit breaker 6.2 Drawout type and Fixed type circuit breaker Installation and Overall dimension, see Fig 8. Circuit breaker right side installation centre hole Circuit breaker Installation baseplate Fixed type 3P/4P cabinet...

 Open the catalog to page 10

All PEOPLE ELE. APPLIANCE GROUP CO., LTD. catalogs and technical brochures

  1. DZ47-63

    2  Pages

  2. LXP1

    2  Pages

  3. RDQ1

    6  Pages

  4. RDX30LE-32

    2  Pages

  5. RDX6LE-40

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.