Catalog excerpts
1 .Application RDR67 series thermal relay(hereinafter refer to as relay),is mainly applied to circuit of AC50Hz or 60Hz, rated operate voltage up to 660V,rated impulse withstand voltage Uimp 6kV,current from 0.11A up to 800A, as circuit and motor protector against overload and phase-loss. Thermal relay has advantages of phase-loss protect,temperature compensation,set current adjustment,auto reset and manual select, move indicator signal,compact install area, multiplied install mode,and has the test button and stop button. It can take operate flexibility test. And it has antitouch protect shell for safety and lock device for anti-misoperate. Thermal relay from 0.11 A to 110A(RDR67-12,18,32,50,75,100) is bi-metal type thermal relay,from 60A to 800A(RDR67-170,300,500,800) is electronic type. This product conforms to standard of IEC60947-4-1.
Open the catalog to page 1Series Relay specification code for frame level rated current design code set current thermal relay company code thermal overload tripping control circuit 3.Normal operate and install condition 3.1 Ambient temperature: Max +40°C,Min -5°C,and day average shall not exceed +35° C. 3.2 Altitude: Install location no more than 2000m. 3.3 Humidity: it shall no more than 50% at +40°C, but the higher humidity is acceptable at lower temperature,for instance,90% is accepted at +20°C.And the condensation shall be taken care. 3.4 Pollution level:3 level 3.5 Protect level:IP20 3.6 Install type III. 3.7...
Open the catalog to page 25. Technical parameter 5.1 Main specification,rated current,set current adjust range,suitable AC contact and match fuse seeTablel Tablel Match contactor model No. wire cross section mm2 5.2 Auxiliary circuit rated insulation voltageUi380V,rated frequency 50Hz/60Hz,Using type,rated operate voltage, rated operate current and rated heating current see Table2 Rated operate voltage Ui V 220 380 220 Rated operate current Ic A 1.64 0.95 0.15 Conventional heating current Ith A 6 6. Shape and install dimension see Fig3 - Fig 10 Fig3 RDR67-12 shape and install-dimension-
Open the catalog to page 3ig5 RDR67-32 shape and ins tall- dimension--
Open the catalog to page 4Figl2 RDR67-300,500,800 shape and install dimension
Open the catalog to page 5Series Relay 7. Installation 1.Set current button 7.1 Thermal relay must be installed by expert. 7.2 Before install,please check Motor rated current whether is in the thermal relay set current range. 7.3 The connecting wire of thermal relay adopts Single core PVC insulated copper wire,copper cable and copper bar,Main circuit connect wire cross section see Table1. auxiliary circuit connect wire cross section less than 1mm², and the all connecting wire and connect terminal should contact well to avoid misoperate of heating because of contact resistance and phase unbalance. 7.4 Circuit diagram...
Open the catalog to page 6All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures
-
DZ47-63
2 Pages
-
LXP1
2 Pages
-
RDQ1
6 Pages
-
WL Series Travel switch
2 Pages
-
RDLX18 Series Travel switch
3 Pages
-
RDD6 series indicator lamp
2 Pages
-
RDJR6 series soft-starter
7 Pages
-
RDI67 series inverter
3 Pages
-
JRS2 Series Thermal Relay
5 Pages
-
RDC67 series AC contactor
3 Pages
-
CJX5 Series AC Contactor
3 Pages
-
RDC6 Series AC Contactor
4 Pages
-
CJX1 Series AC Contactor
4 Pages
-
RDSP6 serie surge arrester
2 Pages
-
RDB67LE-63 series RCBO
3 Pages
-
DZ47LE series RCBO
2 Pages
-
RDL67-63 series RCCB
2 Pages
-
RDL63E-63 series RCCB
2 Pages
-
RDX30LE-32
2 Pages
-
RDX65LE-63 series RCBO
2 Pages
-
RDX6LE-40
2 Pages
-
RDX6LE-63 series RCBO
2 Pages
-
RDB5-63 series MCB
1 Pages
-
RDX6-40 series MCB
2 Pages
-
RDB2-125S series MCB
2 Pages
-
RDX6-63DC series MCB
2 Pages
-
RDX30-32 series MCB
2 Pages
-
RDX65-63 series MCB
2 Pages
-
RDB2-125 series MCB
3 Pages
-
RDB67-63 series MCB
2 Pages
-
RDX2-125 series MCB
2 Pages
-
RDX6-63 series MCB
2 Pages
-
QZB series auto-transformer
2 Pages
-
RDW2-1600 series
13 Pages