Series Moulded Case Circuit Breaker Application RDM10 series Moulded case circuit breaker, mainly applied to the circuit of AC50Hz, rated current from 16A to 630A, rated insulation voltage up to 500V, rated operational voltage up to 400V, it used to power distribution and overload, short-circuit,under-voltage protection of circuit and electronic equipment. Under normal conditions, It also can be used to circuit transfer infrequently. And it can be used to protect and start Motor infrequently. This production conforms to Standard of GB14048.2. Application code(2 for Motor-protection; Non for Distribution protection) Release type and Accessory code(see Table 1) Poles: 3P Operation type(Non for handle control, Z for rotation control ) Frame size rated current Design code Moulded case circuit breaker Company code Table 1 Accessory name Auxiliary Shunt Two contact No Alarm Shunt Auxiliary Under release+ groups +Under of access contactrelease contact -voltage Auxiliary -ories Auxiliary -voltage release contact contact release Instan overcurrent -taneous release type Double type Normal operational conditions and installation conditions 3.1 Temperature: no higher than +40 , and no lower than -5 , and the average temperture no higher than +35 . 3.2 Installation location no more than 2000m. 3.3 The relative humidity: no more than 50%, when Temperature is +40ºC. The product can withstand the higher humidity under lower temperature, for instance, when temperature at +20ºC, the product can withstand 90% relative humidity. The condensation that happened because of temperature changes should be taken care in special measurements 3.4 Class of pollution : 3 Class; Accessories in the circuit breaker pollution class: 2 class. 3.5 Main circuit breaker installation type : lll Class; Auxiliary circuit and control circuit installation type : ll Class 3.6 Installation condition: Vertical installation www.chinapeople.com Email: simon@chinapeople.com

Open the catalog to page 1
RDM10 Series Moulded Case Circuit Breaker - 2

Series Moulded Case Circuit Breaker Main parameter 4.1 Main circuit rated values, see Table 2 Frame size Inm A Rated current range A Rated Rated short-circuit breaking capacity Arc distance operational mm voltage V 4.2 Control circuit Rated control power supply voltage(Us) of Shunt release and Motor mechanism, and Under-voltage release rated operational voltage (Ue), see Table 3 Table 3 Rated operational voltage V Type Shunt release Release Under-voltage release 4.3 Auxiliary circuit Auxiliary contact and Alarm contact of auxiliary circuit, and it can not be seperated in electric. 4.3.1...

Open the catalog to page 2
RDM10 Series Moulded Case Circuit Breaker - 3

Series Moulded Case Circuit Breaker 4.3.3 Auxiliary contact and alarm contact coordinates and cooperates with Short-circuit protection device. Auxiliary contact and alarm contact connects with Fuse (like RL6-25/6), in the inductive test circuit of 1.1 times rated operational voltage, factor between 0.5 to 0.7, it can stand the assessment of 1000A expected short-circuit current in the fuse breaking times. Main technical performance 5.1 Material Circuit breaker shell and shaft insulation part, can fit the requirements of not lower than B class insulation material. 5.2 Electrical clearance and...

Open the catalog to page 3
RDM10 Series Moulded Case Circuit Breaker - 4

Series Moulded Case Circuit Breaker Table 8 Testing current name limit time setting current multiple Initial state Conventional not-tripping current cold state heat state Conventional tripping current heat state cold state c) The breaking characteristic of 3 poles overload release charged 2 poles as it used for motor-protection, 3 poles overload release which charged with 1time setting current from cold state should not tripping in 2 hours under temperature from +38ºC to +42ºC. And then it increases 2 poles current to 1.25 times setting current,and the third pole not charged should should...

Open the catalog to page 4
RDM10 Series Moulded Case Circuit Breaker - 5

Series Moulded Case Circuit Breaker Overall and installation dimension front board connection dimension mm Table 12 Installation dimension mm Order Notice 7.1 Model No. 7.2 Release rated current 7.3 Short-circuit protection current setting value(default is 10In) 7.4 Tripping type and accessories code(see Table1); if shunt release or under-voltage release is in the order, the control power voltage should be noticed.(see Tabel 3); 7.5 Order quantity 7.6 Special requirements should be noticed to the manufacture. www.chinapeople.com Email: simon@chinapeople.com

Open the catalog to page 5