RCCB Residual current operated circuit breaker RCCB Residual current operated circuit breaker ►Application RDL67E-63 series electromagnetic residual current operated circuit breaker, is mainly applied to the circuit of AC50Hz, rated working voltage up to 400V, rated current up to 63A for protecting human indirectly against electric leakage, and for preventing the fire result from the ground fault due to the damaged insulation of the equipment or circuit. Frame size rated current (A) E: Electronic type Design No. Residual current operated circuit breaker Company Code ► Normal working condition and Installation environment 3.1 Temperature: no higher than +40 °C , and no lower than -5 °C, and the average temperture no higher than +35 °C. 3.2 Altitudeof Installation location no more than 2000m. 3.3 The relative humidity: no more than 50%, when Temperature is +40 °C. The product can withstand the higher humidity under lower temperature, for instance, when temperature at +20°C, the product can withstand 90% relative humidity. The condensation that happened because of temperature changes should be taken care in special measurements 3.4 Class of pollution : 2 Class 3.6 The megnetic field of the installation place should not bigger than the earth magnetic field in any direction. 3.7 Installation method: TH35-7.5, distribution box or cabinet. 3.8 Installation: The angle between the vertical plane and installation plane no more than 5. 3.9 Installation condition: the installation location should have no heavy impact and vibration, and in the medium that no danger (explosion). 3.10 Installation type : 2 ,3 Class ► Struction and Working principle This series residual current operated circuit breaker is consisted by Main switch, zero-sequence current transefomer,leakage tripping, testing devices in a plastic case. When the electric leakage and electric shock happening, only the residual current or current leakage reached to the rated residual operated current, the zero-sequence current transformer outputed the signal to drive the leakage tripping operating, then it stops the power to provide the electric leakage and shock protection. Electronic circuit breaker's working priciple see Fig 1. www.chinapeople.com Email: simon@chinapeople.com
Open the catalog to page 1RCCB Residual current operated circuit breaker Main Technical Parameter Circuit breaker basic parameter see Table 1 Framze size Rated workRated rate current voltage Frequency Rated current In(A) Rated residual Rated residual operated current non-operated Rated making Rated residual Residual current current and breaking making Maximum IAn(mA) IAno(mA) capacity Im(A)and breaking breaking capacity Im(A) time (s) www.chinapeople.com Email: simon@chinapeople.com
Open the catalog to page 2All PEOPLE ELE. APPLIANCE GROUP CO. catalogs and technical brochures
-
DZ47-63
2 Pages
-
LXP1
2 Pages
-
RDQ1
6 Pages
-
WL Series Travel switch
2 Pages
-
RDLX18 Series Travel switch
3 Pages
-
RDD6 series indicator lamp
2 Pages
-
RDJR6 series soft-starter
7 Pages
-
RDI67 series inverter
3 Pages
-
RDR67 Series Relay
6 Pages
-
JRS2 Series Thermal Relay
5 Pages
-
RDC67 series AC contactor
3 Pages
-
CJX5 Series AC Contactor
3 Pages
-
RDC6 Series AC Contactor
4 Pages
-
CJX1 Series AC Contactor
4 Pages
-
RDSP6 serie surge arrester
2 Pages
-
RDB67LE-63 series RCBO
3 Pages
-
DZ47LE series RCBO
2 Pages
-
RDL67-63 series RCCB
2 Pages
-
RDX30LE-32
2 Pages
-
RDX65LE-63 series RCBO
2 Pages
-
RDX6LE-40
2 Pages
-
RDX6LE-63 series RCBO
2 Pages
-
RDB5-63 series MCB
1 Pages
-
RDX6-40 series MCB
2 Pages
-
RDB2-125S series MCB
2 Pages
-
RDX6-63DC series MCB
2 Pages
-
RDX30-32 series MCB
2 Pages
-
RDX65-63 series MCB
2 Pages
-
RDB2-125 series MCB
3 Pages
-
RDB67-63 series MCB
2 Pages
-
RDX2-125 series MCB
2 Pages
-
RDX6-63 series MCB
2 Pages
-
QZB series auto-transformer
2 Pages
-
RDW2-1600 series
13 Pages