Motor starter RDJR6 series soft-starter Application AC induction-motor has advantages of low-cost,high reliablity and infrequent maintainance. Disadvantages: 1.starting current is 5-7 times higher than rated current.And it requires that power prid has large margin,and it also would reduce the working life of electrical control device,improving maintainance cost. 2.starting torque is doule-time of normal starting torque to cause the load shock and drive components damage. The RDJR6 soft-starter adopts the controllable thyistor module and phase shift technology to improve the voltage of motor regularly.And it can realize the requirement of motor torque,current and load by control parameter. RDJR6 series soft-starter adopts microprocessor to control and realize functions of soft-starting and soft-stopping of AC asynchronous motor,has complete protection function,and widely used in Motor drive equipment in the fields of metallurgy,petroleum,mine,chemical industry. Non:for install type, G for cabinet type Rated power(applicative power:kW) Design code Soft-starter AC motor Company code production feature Adopts the Microprocessor digital auto control,it has great electromagnetic performance. soft starting,soft stoping or free stoping.The starting voltage,current,soft-start and soft-stop time can be adopted according to different loads for reducing the shock of starting current. stable performance,easy operation,direct display,small volume,digital set,has telecontrol and external control functions. has protection against phase-loss,overvoltage,overload,overcurrent,overheating. has functions of input voltage display,operating current display,failure self-inspection,fault memory. has 0-20mA simulation value output,can realize motor current monitoring.

Open the catalog to page 1
RDJR6 series soft-starter - 2

gS&ittti Bypass output SjgSliii Programme output StJSHiti Failure output m gitstop Transient stop Start Common terminal DCO- 20mA output ► External control terminal definition Switch value state indicator digital display unit indicator up start stop/reset down indicator instruction READY when power on and ready state,this indicator is light PASS when bypass operating,this indicator is light ERROR when failure is happening,this indicator is light A setting data is current value,this indicator is light % setting data is current precentage,this indicator is...

Open the catalog to page 2
RDJR6 series soft-starter - 3

www.peopleelectric.com simon@chinapeople.com

Open the catalog to page 3
RDJR6 series soft-starter - 4

m Motor starter ► RDJR6 series soft-starter ^Appearance and mounting dimension

Open the catalog to page 4
RDJR6 series soft-starter - 5

Ratedd power ► Diagram 376 C www.peopleelectric.com simon@chinapeople.com

Open the catalog to page 5
RDJR6 series soft-starter - 6

Motor starter RDJR6 series soft-starter Application diagram 12.1 Normal control diagram power input AC380V/50Hz soft-starter start/stop bypass control transient stop common part operation indicator programmable failure output output bypass output stop indicator soft-starter fault control fault indicator control circuit Motor Main output signal instruction: 1.External terminal adopts two line tcontrol type.when KA1 closed for starting,open for stopping. 2. soft-starter which above 75kW needs to control bypass contactor coil by middle relay,because of limited drive capacity of soft-strater...

Open the catalog to page 6
RDJR6 series soft-starter - 7

Motor starter RDJR6 series soft-starter 12.3 one common and one standby control diagram fuse stop soft-starter start/stop standby auto-change bypass control ouput signal operation indicator stop indicator failure signal failure indicator stop soft-starter start/stop standby auto-change bypass control operation indicator stop indicator failure signal control circuit failure indicator Instruction: 1.In the diagram,external terminal adopts two-line type (when 1KA1 or 2KA1 is closed,it starts.when they are breaking,it stops.) 2.Soft-starter above 75kW needs to control bypass contactor coil by...